Bad air compressor, big air leaks, no air dryer, axle leak, electrical issue. Water & oil in airtank

2024 ж. 8 Нау.
28 932 Рет қаралды

A failed air compressor wreaks havoc on the entire bus air systems. The electrical systems are a big issue we are just digging into.

Пікірлер
  • The unusually high voltage reading is probably caused by the low pressure buzzer creating this reading on your meter. You can confirm this when the pressure builds-up and the buzzer shuts off; the meter reading should then read 24 volts.

    @hiltonturner9852@hiltonturner98522 ай бұрын
    • That’s what I came to say. Those old style magnetic buzzers could set up some crazy eddy currents.

      @dttprice@dttprice2 ай бұрын
    • Yup, was going to say the same. If his multimeter is set to auto the oscillations created by the buzzer will look like an AC votlage waveform and the meter will auto switch to read the AC. It's a clever safety feature for folks working on AC voltages so you don't accidently have your meter on DC, probe a circuit, see no voltage and grab a wire you thought was safe.

      @KamAbbott@KamAbbott2 ай бұрын
    • I agree. AC spikes from the buzzer. I’m sure that analog meter would show correct DC voltage. But who hs analog meters these days?😊

      @mdomnich@mdomnich2 ай бұрын
    • Not sure that "eddy currents" applies here but the current cannot be instantaneously brought to zero in an inductor. I'd bet that each of the buzzers is a significant inductor. When they open (causing the buzzing) the voltage in their windings has to spike. I'd guess this is what you're seeing. This is sometimes referred to as inductive flyback. That said, although I've seen the lots of places, I'm not a bus mechanic.

      @bruceclarkson1748@bruceclarkson17482 ай бұрын
    • I was thinking the same thing, large counter EMF from the buzzer coil.

      @abpsd73@abpsd732 ай бұрын
  • Scott, hats off to you for discovering a huge need for bus repairs and building a successful business filling that need. I don't own a bus but still love watching the videos.

    @user-uv4mg4ve9p@user-uv4mg4ve9p2 ай бұрын
  • I’m still a firm believer that dot needs to do inspections on anything that is this big….

    @dirtrider383@dirtrider3832 ай бұрын
    • I've been a class A driver for 24 years and I've always felt that anything over a one ton motor home or not should have to go through scales for inspection and have an air brake endorsement for reasons like this. Motor homes are built on truck chassis and most people I've seen over the years don't know anything about air brakes or like spending money on them because they are expensive. Absolutely stupid.

      @chevrolet402@chevrolet4022 ай бұрын
    • DOT operates under the Commerce Clause of the US Constitution. These busses are now used for private use, DOT has no jurisdiction over traveling in your private automobile. Why give them those powers... If so they could come after your personal car or truck next. Freedom comes with responsibilities, people just need to have accountability for their actions is all.

      @shrconstruction@shrconstruction2 ай бұрын
    • @@chevrolet402. I agree. I’m a full time rver and have been working in rv resorts for a few years. I do not understand why the owners of the big class A’s with air brakes can drive these rigs without any training or air brake endorsement.

      @patbullard9276@patbullard92762 ай бұрын
    • @@patbullard9276 The ones that get me are the old retirees when you pull up next to them on the highway and you can barely see them over the steering wheel 🫣 Nothing against age of course just saying.

      @chevrolet402@chevrolet4022 ай бұрын
    • @@shrconstruction i see no difference in requiring dot inspections on anything that is built on a medium duty chassis vs annual inspections on passenger cars.

      @dirtrider383@dirtrider3832 ай бұрын
  • No hair dryer! How barbaric!! The horror! Quick, let’s get a gofundme started.

    @PCMenten@PCMenten2 ай бұрын
  • I I had an older bus, only Scott or his staff would touch it!

    @johnnyhunter4345@johnnyhunter43452 ай бұрын
  • Something often overlooked when dealing with flare connections is the angle of the flare. There are two commonly used angles and they are 37° and 45°. Automotive hydraulic brake lines are normally 45° and AN & JIC fittings along with refrigeration lines are 37°. The oil feed for the alternator seems like it would be 37° since it's more common for that type of fitting. A couple of years ago I got so tired of using those old archaic flaring tools that I gathered up all the ones I had and scattered them in the field behind my shop and ordered a brakequip set with both 37° and 45° dies that go up to 1/2". I make a ton of stainless hard lines for brakes lines, air lines and fuel lines. I don't like using copper lines on automotive appliances due to copper cracking from fatigue and they can become easily kinked due to road debris.

    @ChrisHarding-lk3jj@ChrisHarding-lk3jj2 ай бұрын
  • I’ve watched your channel with much interest for a while now, yet I don’t remember a segment where you had to deal with electrical issues. My heart sunk when I’m watching you test wires and then look at diagrams. What a nightmare!

    @huissens@huissens2 ай бұрын
  • I love and hate the fact that you have a lot of MC7s in your videos. Hopefully someday I can get mine to you.

    @kevinvincent4323@kevinvincent43232 ай бұрын
  • Love these videos, good job once again. ✌️❤️😁

    @robertgriffin7569@robertgriffin75692 ай бұрын
  • Inductive spike - when the buzzer contacts open, the rapidly collapsing magnetic field generates a brief HV spike (basically like a tiny ignition coil), causing the crazy readings on the meter. I’m surprised there’s not a freewheeling diode (a ‘backwards' diode) often put across the coil of a DC operated relay or solenoid that provides a path for the energy put out when the coil is switched off and the field collapses. It prevents these crazy spikes and reduces contact arcing.

    @patmx5@patmx52 ай бұрын
    • That thing was basically an old-fashioned "door buzzer", which is just a relay with a heavy contact arm. The assumption was that the source was robust enough to handle the back EMF being dumped into it. In those days there weren't silicon diodes. A selenium diode would be physically about the same size as the buzzer, would be fairly fragile, and would have a high enough series resistance to not be too useful. So no diode was the obvious choice. I think the problem is that he is powering this with the Power Probe. It almost certainly has a diode from the 24V source it is supplying to the probe tip. So it will supply *at least* 24V to the tip. If the line it is powering wants to generate more (the buzzer) there is nothing to stop it from doing so. The normal connection thru the 6A breaker would have the whole battery shunting the voltage down to 24V, so the problem wouldn't happen.

      @lwilton@lwilton2 ай бұрын
    • @@lwilton Good point - if it were connected directly to the bus' electrical system, the battery would likely act as a clamp and hold the spikes to a much lower level.

      @patmx5@patmx52 ай бұрын
  • I don’t understand how it’s cost effective for you to clean disassemble and rebuild the AD9 at your labor rates when a new one is relatively cheap, it’s like rebuilding a D2 governor you just throw in the scrap heap and put a new one on. I am a fleet mechanic for a highway department in NY. So our stuff is always rusty from road salt so we do not rebuild any of it included brake chambers , and slacks, we use only meritor bonded shoes ,so rust jacking isn’t an issue. Love your channel,and the work you do.

    @JohnDiMartino@JohnDiMartino2 ай бұрын
    • A real bendix 24v ad-9 is $500. A cheap quality clone is $150. But 24v isn’t as easy to get. Waiting a week to get one cost time too or just rebuild it in an hour and also inspect it at the same time

      @BusGreaseMonkey@BusGreaseMonkey2 ай бұрын
  • I used similar flare tool and it couldnt do steel line without heat and bought equilevant to eastwood professional brakeline and tubing flare tool and let me say. It was one of the best purchaces i have done.

    @jrt2924@jrt29242 ай бұрын
  • That air compressor water that accumulates in the tank and filter/water separator in the factories where I used to work I always used to sarcastically refer to as “sweet water”!

    @jamesoestrike2517@jamesoestrike25172 ай бұрын
  • That electrical wiring - water etc - makes my head hurt.....lotta hours could go into it.

    @BlackBuzzzard@BlackBuzzzard2 ай бұрын
  • Hi, when the compressor is passing that much oil the main outlet pipe can also become heavily clogged with carbon due to heat build up in that pipe. Something to be aware of. Cheers.

    @herrkiwi3110@herrkiwi31102 ай бұрын
  • Have the exact copper line on our alternator crack and break off about 2 years ago. Worst part is it happened while driving in the middle of nowhere and blew all 7 gallons of oil out😬

    @RollinHomies@RollinHomies2 ай бұрын
    • That sucks

      @BusGreaseMonkey@BusGreaseMonkey2 ай бұрын
    • With no support.... it will break again. The entire line has to maintain the same frequency otherwise it will work harden. Can take a very long time to occur... but that phenomenon at play.

      @Sum_Tings_Wong@Sum_Tings_Wong2 ай бұрын
    • Carry a spare line

      @johnborn1600@johnborn1600Ай бұрын
  • keep the clips coming

    @lloydrobinson7081@lloydrobinson70812 ай бұрын
  • If you can hook up access to your shop air the clean air should remove all the wet contaminants.

    @371508129@3715081292 ай бұрын
  • Good luck

    @timf6916@timf69162 ай бұрын
  • The high voltage you're seeing is due to a coil somewhere. That is acting like a transformer. Similar to a ignition coil increasing the voltage to a spark plug.

    @methanial73@methanial732 ай бұрын
  • The high voltage your reading is from the buzzer sending back EMF or voltage spikes from the arching of the buzzer contacts it's the same way as a buzz coil works in a model a

    @biggdaddy2001@biggdaddy20012 ай бұрын
  • Mr. George. We have no 9/16.😊

    @jeanneschmidt5628@jeanneschmidt56282 ай бұрын
    • If i was in a hurry i might have just said 5/8 it is when it threaded in…

      @BusGreaseMonkey@BusGreaseMonkey2 ай бұрын
  • Use old fashioned voltmeter for dc measurements. Simpson brand comes to mind.

    @user-gc6ow7ys2s@user-gc6ow7ys2s2 ай бұрын
    • Or... use a diode...

      @Sum_Tings_Wong@Sum_Tings_Wong2 ай бұрын
  • Mili volts ? Maybe. 🤔 I didn’t see the symbol for MV on you meter but that would be strange to be generating that much voltage there. Good luck.

    @woodsontr@woodsontr2 ай бұрын
    • Back EMF from the buzzer. Definitely volts.

      @lwilton@lwilton2 ай бұрын
  • What happened to the nice older man and his huge fleet of busses in Minnesota? I think it was. He loved those busses, me too.

    @alekjuskevice@alekjuskevice2 ай бұрын
    • If you’re talking about Bus Old Man Phil, I believe he passed away a while back.

      @RVsAndCoaches@RVsAndCoaches2 ай бұрын
  • For me ,I would use nylon hose and reroute them tank drains to a readily accessible area just a thought

    @garyharrington5300@garyharrington53002 ай бұрын
    • The pull cords are run to easily accessible locations

      @BusGreaseMonkey@BusGreaseMonkey2 ай бұрын
  • can you use a nice new copper line /as short as it is ,

    @ineverhadthemoney7857@ineverhadthemoney78572 ай бұрын
    • I don’t have any 3/16” copper line

      @BusGreaseMonkey@BusGreaseMonkey2 ай бұрын
  • Is it time to get an Ultra sonic cleaner for washing dirty parts?

    @philgilson260@philgilson2602 ай бұрын
    • How big? 3 foot or larger? We deal with really big parts

      @BusGreaseMonkey@BusGreaseMonkey2 ай бұрын
    • I swear, some of theseuy everything. Hows your tractor holding up? OK I hope. viewers think you can b@@BusGreaseMonkey

      @billtodd6509@billtodd65092 ай бұрын
    • That is hilarious.

      @Sum_Tings_Wong@Sum_Tings_Wong2 ай бұрын
  • Is that bus legal with a cracked windshield?

    @southothehighway@southothehighway2 ай бұрын
    • Is that... blah blah blah...

      @Sum_Tings_Wong@Sum_Tings_Wong2 ай бұрын
  • Interesting-oil cooled generator on that 'ol girl. Thought MCI used belt driven & blast cooled generators on the MC-7 & MC-8 buses-at least the ones I played with as a young man way back in the late 1970's.

    @stevenrobinson2381@stevenrobinson23812 ай бұрын
    • It’s a transplant from a fire truck i think.

      @BusGreaseMonkey@BusGreaseMonkey2 ай бұрын
  • 🙂

    @isaacsims6203@isaacsims62032 ай бұрын
  • I'd go with a new AD9,

    @billbrown7583@billbrown75832 ай бұрын
    • It’s good as new now.

      @BusGreaseMonkey@BusGreaseMonkey2 ай бұрын
  • 😃😃😃👍👍👍

    @user-ix5qy2jk7h@user-ix5qy2jk7h2 ай бұрын
  • Electrical gremlins ⚡️👹 yuck

    @davidowen888@davidowen888Ай бұрын
  • You need an meter that reads ture RMS that's design for electronics that's why you are getting all the odd readings

    @roberthardman3774@roberthardman37742 ай бұрын
    • That's literally what he's using lmao. His problem is feedback from an analog buzzer.