Outdoor Outlets on Deck or Pergola | Skip the Conduit!

2023 ж. 9 Шіл.
276 861 Рет қаралды

Get a 60-day free trial at shipstation.com/april. Thanks to ShipStation for sponsoring the show!
My Entire Collection of Plans: wilkerdos.com/product-categor...
Subscribe: bit.ly/3gfe5YL | Website: wilkerdos.com
Watch the newest videos: bit.ly/3hBOdaf
Things I Used in This Project:
Ideal Industries In-Sure® Lever Wire Connector, 3-Ports: bit.ly/3pyGhNX
Ideal Industries Reflex Super T-Stripper Dual NM: bit.ly/3PRKLde
DAP Barrier MultiProject Foam: bit.ly/3XZNt2p
ISOtunes Hearing Protection: bit.ly/WilkerDos (use code APRIL for 10% off)
Website: www.wilkerdos.com
Patreon: www.patreon.com/user?u=257047
Instagram: / wilker_dos
Facebook: / wilkerdos
Manufacturing and retail site: hillcountrywoodshed.com/
Want to support me? Support the companies that support me:
Triton Tools: bit.ly/2jaC0dD
ISOtunes: bit.ly/2YuZBtr
Welcome to the official April Wilkerson KZhead channel. I’m April and I’m the creator of Wilker Do’s. I'm not professional or have any training, so I just pick the project I want to tackle and figure it out step by step. On this channel you will find a variety of content like DIY home improvement, How-To’s, construction and more.

Пікірлер
  • Conduit isn't just for watertightness. Conduit protects the wires from being damaged accidentally. It'sa safety feature that should not be skipped in an outdoor installation.

    @kmoecub@kmoecub10 ай бұрын
    • There are cables with a metal sheeting that can take some hits before getting damaged. Here in Sweden we rarelly use conduit outside for normal outlets and lights. We do still use them for power distribution cables that goes to other breaker boxes but that is because the higher current cables are so expensive when they have metal sheating. Usually only power companies use those to feed power between houses in the ground.

      @Dragonited@Dragonited10 ай бұрын
    • She's wrong in saying conduit is for water protection. I'd say conduit is good additional protection, but it isn't necessary. Armoured cable is the alternative. I've put armoured cable in conduit, not so much for protection, as for any subsequent need to rewire.

      @cuebj@cuebj10 ай бұрын
    • Over kill, mc cable is way more expensive than thhn.

      @chaser9363@chaser936310 ай бұрын
    • It also helps to keep rodents etc from chewing on the wires

      @lechatbotte.@lechatbotte.10 ай бұрын
    • I always use PVC conduit for any outdoor installation because protecting the wires from critters is just as important as protecting them from moisture and physical damage This one friend of mine who's an electrician told me he has had alot of calls to fix shorted out equipment along with damaged wiring caused by critters and he said it was hell because in almost all cases , The wiring and the equipment had to be replaced because of the severity of the damage critters do , Also I use single conductor wires in conduit because they allow for heat dissipation when using a high wattage appliance , Running Romex or UF cable in conduit traps heat and is not allowed by code in many areas

      @ironmartysharpe8293@ironmartysharpe829310 ай бұрын
  • Great video with your useful step by step instructions and advice. Thanks for sharing this one April! Hope you’re having a great weekend!

    @WillysPerformanceCycleCtr@WillysPerformanceCycleCtr10 ай бұрын
  • I hate to be Safety Sally here, however; Keep in mind that NM-B cable shouldn't be installed in conduit. Individual rated wires such as THHN would be used only in conduit. Because of the outer sheath, NM cable can't get rid of the heat, and is already derated to 60C even though the wires are rated for 90C. If you remove the jacket you also remove the approval of the wire. Also any conduit used below grade or above grade in wet locations is indeed considered to be wet inside. (article 300-5(b) and 300-9) And because NM-B can't be used in wet locations, you can't use it in conduit, again THHN or equivalent approved should be used Also NMC (UF-B) must be protected (article 334-15(b)) states in part: 334.15 Exposed Work. In exposed work, except as provided in 300.11(A), cable shall be installed as specified in 334.15(A) through (C). (B) Protection from Physical Damage. Cable shall be protected from physical damage where necessary by rigid metal conduit, intermediate metal conduit, electrical metallic tubing, Schedule 80 PVC conduit, Type RTRC marked with the suffix -XW, or other approved means. Article 340 also goes on to state that because UF-B is NM cable, it must be protected and in conduit above ground in wet locations. It can be directly buried at least 18-24" deep without conduit, but once out of the ground must be protected in conduit. 🤷‍♂🤠

    @Chris_In_Texas@Chris_In_Texas10 ай бұрын
    • Great information. You put "NMC (UF-B)" but these are two different cables types are they not? You can't direct bury "Type NMC" (plastic rather than paper sheath), but UF-B is meant for direct burial. I'm not sure if that changes your reading of Article 340, I was hunting for it but gave up. I'm just an amateur. 😉 I remember I had just read "Wiring Simplified" cover-to-cover and a buddy was burying Type NM in conduit, and I was pretty sure I had just read that it was considered a wet location. Yeah, 334.12 (Uses Not Permitted) was amended in the 2008 version to include "In damp or wet locations". This install was in like 2009. I was ignored of course.

      @CodeOptimism@CodeOptimism10 ай бұрын
    • Thank you 🙏

      @wtrf22@wtrf2210 ай бұрын
    • Could you provide a reference to NEC where it states NM is not allowed to be run in conduit?

      @pfa231@pfa23110 ай бұрын
    • @@pfa231 ... I forget where I saw it in NEC, but recalling you can put NM in short runs of conduit for protection. IOW, running bare in the rafters, but a few feet of conduit down a wall in a basement would be "for protection" and also for fastening to the concrete block wall where you can't normally run NM cable. What you shouldn't do is run it 20 feet across the garage ceiling in conduit.

      @rupe53@rupe5310 ай бұрын
    • @rupe53 NEC 2011 (the only one I have here) specifically calls for NM to be run in conduit in 334.15. There is nothing wrong with NM in any length of conduit (apart from conduit sizing issues and being a nightmare to pull).

      @pfa231@pfa23110 ай бұрын
  • The deck series is amazing April…. Nicely done ❤

    @mlubecke@mlubecke10 ай бұрын
    • Thank you so much!

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Always check with your local inspector. External receptacles may have extra requirements. In my area, outdoor outlets must be weather resistant and all exposed wiring must be in conduit. She says it quickly towards the end, but always check local requirements. They are intended for your safety.

    @TomCee53@TomCee5310 ай бұрын
  • Thanks for the info April! 😃👍🏻👊🏻

    @FredMcIntyre@FredMcIntyre9 ай бұрын
  • Good afternoon, April! Thanks for sharing! Something else to add to my list. 😁

    @louroberts5567@louroberts556710 ай бұрын
  • Even though I've done jobs like this in the past, I always pick up something new from you, April. Thanks!

    @charliehustle544@charliehustle5448 ай бұрын
    • So glad! That's great to hear. Thanks for watching.

      @AprilWilkerson@AprilWilkerson8 ай бұрын
  • Loving the deck 🤠

    @OriginalRaveParty@OriginalRaveParty10 ай бұрын
  • Best deck on KZhead hands down! Thanks April :)

    @jimmyjames3220@jimmyjames322010 ай бұрын
  • Thank you. It's very informative, short, straight to the point.

    @lexuannhi@lexuannhi9 ай бұрын
    • Thanks! Glad you found it useful. Thanks for watching.

      @AprilWilkerson@AprilWilkerson9 ай бұрын
  • Hi April... love watching your videos. They're always so informative for the do it yourselfers. Keep them rolling and hope all is well on your end!❤

    @alanwilliamson9350@alanwilliamson935010 ай бұрын
    • Thanks so much!

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Thanks for more good information April. Stay safe and keep the great videos coming. OLD DAWG DREAMING Fred.

    @olddawgdreaming5715@olddawgdreaming571510 ай бұрын
  • Nice installation. I prefer conduit just because I think it makes a neater installation. I have not seen the water proof outlet cover before. Looks very good. Thank you for sharing. Have a great day and stay safe.🙂🙂

    @glencrandall7051@glencrandall705110 ай бұрын
    • Thanks!

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Nice job April. For those that don’t know, UF stands for underground feeder. UF cable is rated for wet environments and direct burial. Romex is not rated for wet environments so UF is the right cable for under the deck.

    @markgallagher1376@markgallagher137610 ай бұрын
    • Like you just stated it is for underground not above ground use so no this wouldn’t be right thing to use unless you put it in conduit

      @jdrl143@jdrl1439 ай бұрын
    • @@jdrl143 if it can handle the conditions under ground it certainly can handle the conditions under a deck. Where does it say in the code that UF must be buried or in conduit? And to everyone talking about pests chewing on the UF cable, the same thing happens in attics when rodents get in. And if you’ve been in any attic in New England there is always signs of mice even in new houses.

      @markgallagher1376@markgallagher13769 ай бұрын
    • UF is also UV rated so I don't see an issue with above ground use. Would like to see a weather rated outlet though

      @eflemming75@eflemming759 ай бұрын
    • The issues s not rodents but accidental damage by humans. Anyplace that is unfinished but accessible by humans may need conduit. Always check with your inspector. Codes are for our protection.

      @TomCee53@TomCee537 ай бұрын
    • @@TomCee53 what she did is not against code. I wouldn’t consider that location to be a place that is subject to physical damage. It is stapled along the porch joists. No different than romex running along floor joists in the basement or ceiling joists in the attic. If we follow your logic everything that is concealed in a wall would have to be in a conduit. And don’t forget the jacket on UF cable is 10 times tougher than romex jacket.

      @markgallagher1376@markgallagher13767 ай бұрын
  • I learned something new and valuable, deserves a tip! Thanks!

    @tradermunky1998@tradermunky199810 ай бұрын
    • Thanks! I'm glad you found it useful and I appreciate the Tip. Thanks for watching.

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • hello April awesome video on wiring outlets ya has come a long ways with this project so kool have a great the rest of your week be safe 💕

    @jrpritchard1622@jrpritchard162210 ай бұрын
    • Thank you! You too!

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Electricity is not hard if you just pay attention to what you are doing. My dad was in that business and now we hardly ever have trouble. Like you said getting the wire to where it needs to go is the toughest part of the job. That was an excellent video. Thank you.👍♥️

    @dennishinkle5010@dennishinkle501010 ай бұрын
  • Love this project.

    @upallnyte2000@upallnyte200010 ай бұрын
  • Always informative! Thanks, April.

    @kevinbowker2385@kevinbowker238510 ай бұрын
    • Glad it was helpful! Thanks for watching.

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • That is a neat trick, and it probably is legal in most areas. I used to work at a big box hardware. When customers always asked what the purpose of conduit was I always told them it is to keep fools and dogs from chewing on the wires. Please remember the elements are not the only thing to worry about.

    @gregryeii403@gregryeii40310 ай бұрын
    • Even though type UF cable was being used and is easier to run and even though it was ran under the deck , The problem is that it's exposed that critters can easily get at it and start chewing on it , You're much better off to use PVC conduit for better protection against moisture and physical damage and also critters This one friend of mine who's an electrician told me that he's had alot of calls fixing damaged wiring and equipment caused by critters and he hates it

      @ironmartysharpe8293@ironmartysharpe829310 ай бұрын
    • @@ironmartysharpe8293 I ran my outdoor internet and computer wiring in PVC just so the critters don't see it and immediately think it's licorice.

      @ghost307@ghost30710 ай бұрын
    • I found some UF cable that had been run about 3" below ground level. Digging into a powered cable is not my idea of fun, so I removed it.

      @richmorin424@richmorin42410 ай бұрын
  • Thanks April. Good stuff, as always.

    @marksrs69@marksrs6910 ай бұрын
    • Thanks, glad you enjoyed it.

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Hello hope all is fine with you and family. Love your videos because you keep it simple for those of us that are slow on the uptake!

    @franko3227@franko322710 ай бұрын
    • Thank you so much! Yes, people forget not all of my Viewers are on the same skill level. I know starting out, I needed someone to explain what I need and why, then show me how. I'm glad you find it useful. Thanks for your kind words and for watching.

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • "It's just a garage." I think your viewers need to know that some of the walls in an attached garage are RATED WALLS, meaning you cannot just cut the drywall and not patch it back in. In your case, the wall was shared with the outside, not living space, so it may not be as big of a deal, unless there is a habitable space above your garage, in which case I think you need to patch it so that fire cannot travel up the stud bay.

    @steveloux4709@steveloux470910 ай бұрын
  • Very nice always helpful! Your always fun to watch!!!

    @mikecurtis2585@mikecurtis258510 ай бұрын
  • Been married to my wife and living in a house she already had for 18 and a half years. We have a very large covered deck out back and I always wanted a plug. Had an electrician install a Generac last year and I got him to put in a plug which has been great. Now we have sold our house and moving in about 30 days to a brand new house that will have a deck plug and ceiling fan. Great video and recommend anyone who has a deck to have a plug.

    @chargerman165@chargerman1659 ай бұрын
  • Thanks for making outdoor wiring easy April! You always do excellent research. This will save me a lot of time during my next outdoor wiring job. I especially like the Lever Wire Connectors, and the Wire Strippers. Thanks Again and Enjoy a Great Day!!!

    @BearCreekWoodworking@BearCreekWoodworking10 ай бұрын
    • Thanks! I'm glad you enjoyed it.

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Cool, Cheer April. Great video as usual.

    @ianpearse4480@ianpearse448010 ай бұрын
    • Glad you enjoyed it!

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Nice job! Glad to see you used gfci protection and great idea putting it indoors. Gfci outlets don't really last long with outdoor exposure, even the Wet Location ones. As an electrician I can tell you, UF cable is usually intended for burial because it's protected when used underground at certain depth. The cable should not be exposed and should be mechanically protected anywhere above ground. The jacket is more water resistant but not really UV or critter resistant. If you are going to leave it this way, maybe change the outlet to a combo gfci/afci for better protection, incase case a rodent gets the munchies or gets damaged by a piece of yard equipment.

    @ronlovell5374@ronlovell537410 ай бұрын
  • Nice. You may want to have a look a Klein Tools or Knipex pliers for electrical work. Also Wago lever nuts are preferred by most DIYers. One suggestion... Regarding the box (or boxes) you mounted below the deck, I suggest you leave drip loops where your wires enter the box that will mean much less dependence on those rubber bushings. And, you may want to mount these boxes slightly off horizontal and drill your drain hole in the lower corner. This reduces the chance for standing water inside the box.

    @deanrhodenizer938@deanrhodenizer93810 ай бұрын
  • I used romex in PVC conduit on my deck and the one issue I never counted on , was how much expansion / contraction I had with the seasons ... It's a fairly long run and an expansion joint needs to be put in the run. Nice video...

    @ral819@ral81910 ай бұрын
  • If I'm doing old work, I've switched to using Southwire Smart Boxes if I'm near a stud instead of the butteryfly types.

    @SeanReifschneider@SeanReifschneider10 ай бұрын
  • Please note that what meets electrical code in your area does not necessarily mean it applies elsewhere, even within the same country. Much of what was shown here would not meet code in my county.

    @alexrosenberg_tube@alexrosenberg_tube10 ай бұрын
    • Your county seems very strict. I didn’t see any NEC violations in this installation. But I have been out of the game for a while so I’m not up on the latest NEC.

      @markgallagher1376@markgallagher137610 ай бұрын
    • Hence her statement of "in your area"!?

      @chrissewell1608@chrissewell160810 ай бұрын
    • I’d be curious to know what specific code violations you see

      @toddcoble1485@toddcoble148510 ай бұрын
    • @@markgallagher1376technically the weep hole in the outdoor box (I wouldn’t fail it), and the receptacle doesn’t look like a WR receptacle.

      @toddcoble1485@toddcoble148510 ай бұрын
  • Great video you are certainly well versed on the subject. I would tend to stick with a conduit unless I was convinced the cable run couldn’t be physically damaged or eaten by critters. I live on the Texas coast and salt fog corrosion is a nightmare especially for GFI circuits. So the value of this video to me was seeing what material options may work best.

    @yellowboxster06@yellowboxster0610 ай бұрын
    • I think the greater hazard would be someone thinking it's OK to HANG SOMETHING off the exposed cable, which is why code gets finicky in locations like outdoors (esp. between structures) or laundry rooms.

      @VideoNOLA@VideoNOLA6 ай бұрын
  • Great video on some how to wiring. I like the idea of installing outlets with the USB ports as well, very handy

    @guybowers9094@guybowers909410 ай бұрын
    • personally, I feel USB ports belong at a table or countertop height. Why put expensive electronics near the floor to charge? Even if the cord will reach, why bend over that far to plug stuff in? You wind up stepping on the cord or kicking things too close to the floor.

      @rupe53@rupe5310 ай бұрын
    • Glad it was helpful!

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Another great video thanks

    @jonasgrumby9065@jonasgrumby906510 ай бұрын
    • Glad you enjoyed it. Thanks for watching.

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Great wiring video👍

    @BartlettTFD@BartlettTFD10 ай бұрын
    • Thanks!

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Bonjour . Depuis le temps que je regarde vos sublimes post , une chose est sur , vous êtes géniale est vous avez pris aucunes rides , Bravo chère April . Amitiés venant de la France ( Europe )

    @stephanedufour3150@stephanedufour315010 ай бұрын
  • nice job

    @howardemery1443@howardemery144310 ай бұрын
  • FYI, you are only allowed to use 40% of the internal volume of the conduit to run wires. NEC (National Electric Code for the US) states that in black and white inside of it.

    @kargandarr@kargandarr9 ай бұрын
  • Glad to see you healthy and doing well! Great content as always!

    @bradleyclark5936@bradleyclark59369 ай бұрын
    • Thanks! I'm glad you enjoy my channel. Thanks for watching.

      @AprilWilkerson@AprilWilkerson9 ай бұрын
  • Hi April always enjoy your videos and i always learn something new. What kind of "in use" outlet cover did you use on the deck? Thanks again

    @aquaman461@aquaman46110 ай бұрын
  • Used this process to wire our deck. I have had a couple issues in the last 25 yrs with that decision..both self inflicted. 1. I have everything wired through a gfi , so I had to have a line / load tutorial with an electrician friend. 2. I had a never used plug hidden from view, so I forgot it was there. Over the years, it eventually got about a 1/2” of water in it. Well, water & power.. you know the rest. Eventually found the issue, removed the plug & we’re good again.

    @harryvandenbrink1688@harryvandenbrink168810 ай бұрын
  • They make a self adjusting wire stripper that you can use to cut and strip romex. No need to know the wire Guage and is by far the best purchase I made in adding electric to my deck.

    @PtrOBrn@PtrOBrn10 ай бұрын
  • My new idea on the dock maybe and porch

    @chriswalls5831@chriswalls5831Ай бұрын
  • I always use PVC conduit for outdoor installations because type UF is for direct burial and not only does the installation have to be water tight , There's critters that will chew on UF cable if ran on the surface , Even though it's ran under the deck , It's still exposed which critters can get at it and depending on your area , may not meet code so check the codes in your area before you begin Also whenever I do an outdoor installation installation I use single conductor wire , Not run Romex or other cable in the conduit because if you plug in a high wattage appliance , Single conductor wire allows for heat dissipation and Romex or other cables ran in conduit is not allowed by code in many areas , So always use PVC conduit to protect the wiring not only from moisture but from critters as well One of my electrician friends was telling me about alot of calls he had to go on fixing shorted out electrical equipment caused by rodents and other critters and almost every time , Had to replace the wiring because of the damage the critters did along with the short circuits

    @ironmartysharpe8293@ironmartysharpe829310 ай бұрын
  • I admire that there is nothing that you won’t tackle, April, and enjoy all your videos. I also watched and enjoyed all the Assembly Required shows. I would like to have seen how you ran the Romex thru the existing conduit with the multiple 90 degree turns and the length. Did you use air pressure to feed a pull string? It had to be a pain.

    @JT_70@JT_7010 ай бұрын
  • I like how much she emphasized building code in this video. If you're going to take something like this on, make sure you do it RIGHT.

    @poshko41@poshko419 ай бұрын
  • I just want to say that I think your truly amazing, and the way you explain yourself and projects are top notch. Also I’m sure you’ve probably already heard this today but I just want to say that you are absolutely Gorgeous and I believe I have done fell in love with you Mam lol Keep up the amazing work. Thank you

    @trustindustin2@trustindustin210 ай бұрын
  • Nice Job :-)

    @daveallen2455@daveallen24558 ай бұрын
    • Thanks!

      @AprilWilkerson@AprilWilkerson8 ай бұрын
  • Hi, it might be interesting for your viewers how to make sure that power is off when performing work with electricity, since many people just turn off the breaker and don't test, or they use NCV-Testers or Multimeters instead of proper electrical testers and they don't know the process of testing and turning it off reliably (locking it, etc.). This is such an important task and I would love to see you make a video about it to raise awareness... Thank you!

    @Cymaphore@Cymaphore10 ай бұрын
    • A multimeter is a proper electrical tester...

      @ve4edj@ve4edj5 ай бұрын
  • what's the machine that looks like an air compressor with a digital read out? I got distracted by that!🙂

    @andrejrasevic6088@andrejrasevic60889 ай бұрын
  • Yeah being sealed from the elements is really only about 10% of my concern when burying electrical: 90% of the time myself, my family, or some critter accidentally severing the underground wire is much more likely, so I opt for conduit for the extra protection it provides from that.

    @j0elyman@j0elyman26 күн бұрын
  • more power :)

    @SdBoy@SdBoy9 ай бұрын
  • Are those outlets on a GFCI breaker? Pretty sure receptacles outside needs to have GFCI protection

    @osamaslama7218@osamaslama72189 ай бұрын
  • Which kind of conduit up the post?

    @counseloridealist@counseloridealist7 ай бұрын
  • Liquidtight would be an excellent choice hear. I think in some regions, Romex installed like was done in the vid will not pass code. Animals can chew the sheath of the wiring. Do it right and do it once.

    @Yorkiepoocharlie@Yorkiepoocharlie10 ай бұрын
  • Good Job! I am guessing that one reason conduit is used, is to add an extra layer of protection from SQUIRRELS! Squirrels and/or rodents love to chew wires, especially if the wire is coated with a soy-based covering. Newer Cars that have soy-based wire, are being destroyed by the varmints! You should build a Bat House, since bats love to eat insects, and the Texas Hill Country has many bats. Bats are your silent friend!

    @alansmith4734@alansmith473410 ай бұрын
  • Please share your golf simulator set up! I want to compare it to mine. ⛳️

    @hammockmonk@hammockmonk10 ай бұрын
  • As a 40+yr commercial/industrial electrician, I am impressed with the skill level of your installation. The only things I would add are: Install a bushing on the threads of you male adaptor and pull loose conductors in the conduit (if you didn't do this already) NM cable is not rated to be pulled into conduit with rated conductors. As far as a DYI- excellent video!

    @N719SM@N719SM10 ай бұрын
    • Thanks! I'm glad you enjoyed it. Thanks for watching.

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Another great video Ms April 👍

    @_Merica_USA@_Merica_USA10 ай бұрын
    • Thank you so much!

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • I mean, for a home-gaming KZheadr carpenter, this is fine. I've seen so many rat nests by proper electricians that I appreciate someone who can staple a run within 15 degrees of its home run.

    @KittySN@KittySN10 ай бұрын
  • God! You sure are doing a great job dragging this series out.

    @MrOmin13@MrOmin1310 ай бұрын
    • I try to keep my videos sticking to one subject at a time and 8 mins or less. People get anxious and click away to check out other channels, etc so too long and people never see the end.

      @AprilWilkerson@AprilWilkerson10 ай бұрын
  • Omg. You built that deck and know all this electrical jazz. #superwoman whoa. Glad I found your channel. Are you in the south Florida area?

    @delraydogwalks@delraydogwalks28 күн бұрын
  • Q: on outlets I have a GFCI I want to mount a 75” 4K tv on my wall eventually when I have time but can I daisy chain power cable from bottom outlets to a gfci outlet that is going behind my 75” tv when mounted

    @williamwilkinson8289@williamwilkinson828910 ай бұрын
  • In use outdoor cover not required if under a roof, like a porch roof.

    @bobbray9666@bobbray966610 ай бұрын
  • Nice project! Is there a combination junction box / outlet cover thats more sleek?

    @michaelsmithers4900@michaelsmithers490010 ай бұрын
    • you can get a shallow box but all of the weatherproof when in use covers stick out more than most people like.

      @rupe53@rupe5310 ай бұрын
    • Yes, get a Hubbell pop out cover. That's what I used to replace my broken cover in back. You have to pull it out if you want to use the in use corner for the extension cord, but it's very sleek. Much less of a tripping hazard compared to what April installed here.

      @whattheschmidt@whattheschmidt10 ай бұрын
    • I was looking at that too. One is required to do all the work for electrical safety, but end up with a giant tripping hazard. I think a flush mount located at the point of use could be better in this instance.

      @zugzug2849@zugzug284910 ай бұрын
    • @@zugzug2849 ... yes, a trip hazard is a real concern, but so is a broken cover, that most people will never replace. Besides, that same broken cover can cut the crap out of your leg as you walk by. Mounting on a different side of that post (out of traffic) is probably the best solution.

      @rupe53@rupe5310 ай бұрын
  • case for natural selection

    @SuperMatt1969@SuperMatt19699 ай бұрын
  • Your local area may allow romax outside, but the NEC code book doesn't allow it. The drilled hole may also be not allowed,

    @anonymousperson4363@anonymousperson436310 ай бұрын
  • Rodents, Squirrels can chew the electrical wire if exposed... If you don't run conduit, then use BX wire.

    @canconservative8976@canconservative897610 ай бұрын
  • I have some lever lock connectors for using with 12vdc, but I don't think they are 110 vac approaved! So, use the right equipment, when running house power!

    @chrissewell1608@chrissewell160810 ай бұрын
    • Those types from ideal and wago are approved for residential use

      @jake-mv5oi@jake-mv5oi10 ай бұрын
  • FYI see National Code NEC 300.5(D)(1) . Above 8 feet you will be ok but if the UF riser comes from grade level conduit is required to 8 foot point. And, if you have gone that far might as well hang conduit for the rest. Of course your local building inspector may have something to say about exposed UF on the order of " rip it out and do over I am not approving that". I find running conduit easier than than arguing and much safer. We have voracious squirrels and clumsy contractors here.

    @johndawson6084@johndawson608410 ай бұрын
  • Intresting, cool looking deck. Although the plug for the electrical outlet should be put in flush with outside of the box. This doesnt allow water too pool in the threaded cavity

    @acupoflego@acupoflego10 ай бұрын
    • In areas that freeze, having the cavity filled with water and then freezing could lead to a crack in the box allowing water to enter the box. In theory, the GFCI would shut down the circut, but it could be a tough job to figure out why the GFCI keeps tripping.

      @mikewatson4644@mikewatson464410 ай бұрын
  • I use GFCI outlets for my outside boxes. They aren't all THAT expensive and they keep me from having to go inside to find the popped GFCI button. In fact, I very seldom use the LOAD terminals on a GFCI outlet...

    @richmorin424@richmorin42410 ай бұрын
  • Nice video but technically that small piece of conduit from the receptacle should have a female adapter with romex connector screwed into it. That UF cable should be support ed at the end of the conduit.

    @lucagreco7455@lucagreco74559 ай бұрын
  • Question: if you came from the garage circuit to th wide to an outlet outside, the garage circuit is supposed to be gfci protected anyway. How did you add another gfci outlet to a gfci protected circuit?

    @BG-gi4tp@BG-gi4tp9 ай бұрын
    • should read: If you came off the garage circuit to add a gfci outlet...

      @BG-gi4tp@BG-gi4tp9 ай бұрын
    • Did you tap the breaker that feeds the garage circuit?

      @BG-gi4tp@BG-gi4tp9 ай бұрын
  • Running additional wire in an existing conduit may exceed the maximum number of wires that can be in the conduit.

    @allen4353@allen43539 ай бұрын
  • A weep hole in a watertight box sounds like it could be an issue depending on the climate, Water vapor in high humidity environments would just collect water in the box and sit on your connections. Not a point out of experience, just thinking out loud. If someone has experience I'd like to hear about it.

    @FailedFace@FailedFace10 ай бұрын
  • I like how that outdoor box has 2 tabs on both sides, I can’t stand when they only have 2 tabs on the diagonal.

    @jeremyspecce@jeremyspecce10 ай бұрын
  • You do not need tha male coupler , you must ream the pvc . Or if you are going to use the male coupler you need a plastic bushing on it if . The fitting itself is not necessarily considered to be “bushed”

    @gerdberg4188@gerdberg418810 ай бұрын
  • I've hard romex in conduit is not water tight or good practice. But perhaps that's because I've been dealing with burying. Is it allowable if you're above ground?

    @TrotterG@TrotterG10 ай бұрын
    • Romex should never be used outdoors, even above ground in conduit.

      @jasonkloos6348@jasonkloos634810 ай бұрын
    • It's not technically illegal to have romex in conduit, but it's generally frowned upon due to the potential for heat buildup. Usually you'll want to either run individual THHN wires, or strip the outer sheathing off the romex before running it through conduit.

      @mattdever6835@mattdever683510 ай бұрын
    • @@mattdever6835 Good point about not running Romex in conduit, but the individual strands of Romex have no temperature rating stamped on them and would also be a no-no. THHN is the way to go in conduit. The local inspector would probably reject this DIY job, unfortunately.

      @JaegerDives@JaegerDives10 ай бұрын
    • Romex isn't allowed in wet/damp locations, and outdoor conduit is considered one of those. The issue is the insulation. Romex can be run in conduit indoors, it's just difficult to do. UF is of course allowed outside, since it's designed to be buried (hence the Underground Feeder designation). I'm unclear on whether it can be run the way April did it. Probably, but Romex must inaccessible in normal use, and protected from damage.

      @bmay8818@bmay881810 ай бұрын
  • Curious, April, what was your wire gauge on the UF wire run below the deck? I am doing the same thing, but my wiring is running under a roof overhanging on the deck I am building. Thxs

    @bigguydiy2184@bigguydiy218410 ай бұрын
    • wire gage is relative to the breaker size, same as indoor wire. #12 for 20 amp circuits.

      @rupe53@rupe5310 ай бұрын
    • @@rupe53 Thank you. I was planning on #12 and already bought the 20 amp sockets, just not the wire yet.

      @bigguydiy2184@bigguydiy218410 ай бұрын
    • @@bigguydiy2184 ... did you know you can use 15 amp sockets as long as there are several on the circuit? You really only need 20 amp units if it's industrial or a single dedicated receptacle on the wire run. All 15 amp units allow 20 amps on the pass-through to the next unit.

      @rupe53@rupe5310 ай бұрын
    • @@rupe53 a 15 amp duplex is considered 2 receptacles.

      @tchevrier@tchevrier10 ай бұрын
    • @@tchevrier ... true, but the reason it's code is because it's 15 amps on the pass through to the next receptacle

      @rupe53@rupe5310 ай бұрын
  • Does your local code not require mechanical protection of the cable at 4:58 or other parts? I would be worried if the underside of the deck is going to be used for storage of any kind, the cable could become damaged while moving stuff in and out. In that case the conduit would not be for protection from water/UV but rather from mechanical damage.

    @jd9875a@jd9875a10 ай бұрын
  • April, I've been watching your channel for a very long time. Too bad you hid your earliest videos. It is impossible to appreciate the greatness of a mountain if we do not see its foot, but only the top.

    @Ambulare-Cum-Canem@Ambulare-Cum-Canem9 ай бұрын
  • Romex inside conduit? I heard somewhere this is a no-no. Not allowed by code. Maybe an electrician can verify or not.

    @denjhill@denjhill10 ай бұрын
    • not allowed in an industrial setting. ok for residential work.

      @marzsit9833@marzsit98339 ай бұрын
  • Tip or suggestion, not criticism. But you can take the ears off the outlet so the cover plate sits flat against the wall when using an old work box.

    @jeremystone1931@jeremystone193110 ай бұрын
  • Not all areas allow wires to be stapled to underside of joist. Only THHN stranded wires are to be used in conduit. Drilling a drain hole in an outdoor outlet introduces moisture in the form of condensation from the heating and cooling of the outlet and wires thus shortening the life of the outlets.

    @smarthome2660@smarthome266010 ай бұрын
    • The actual outlet on the front isn't airtight... Any condensation would exist regardless of a hole. I do think it's unnecessary, but I don't think it'll harm anything.

      @PSNDonutDude@PSNDonutDude10 ай бұрын
    • @@PSNDonutDude I am referring to the gaskets that keep out air thus moisture. A hole defeats this purpose.

      @smarthome2660@smarthome266010 ай бұрын
    • And insects too ever heard of fire ants the love to get into electrical equipment 😮

      @BrianHurtt-uu1sk@BrianHurtt-uu1sk9 ай бұрын
  • Would not the metal fittings on the plastic FS box need to be grounded as they are metal? A metal FS box would allow you to put your ground wire to the box thereby grounding the box and the fittings.

    @Privat2840@Privat284010 ай бұрын
  • Electrical installation in the US always looks medieval and rough to me as a german. At least you found out about wago clamps recently.

    @marcus_w0@marcus_w010 ай бұрын
    • I agree it's so much simpler here in Australia

      @699hazard@699hazard10 ай бұрын
    • @@699hazard AFAIK, Australia has most of the same standards as in germany or europe in general.

      @marcus_w0@marcus_w010 ай бұрын
    • I think some of our wiring components/methods are worse than yours, and some are better. We definitely cheap out in some areas. But I'll take a big metal American breaker box over one of those small plastic DIN rail boxes any day.

      @bmay8818@bmay881810 ай бұрын
    • @@bmay8818 Because plastic boxes are less prone to shocks and short circuits? A metal enclosure for a live installation just sounds like a really bad idea... I agree, a insulated plastic box is way less impressive and adds almost no spectacle compared to a metal enclosure spitting sparks and fire everywhere in a very fire safe wooden home.

      @marcus_w0@marcus_w010 ай бұрын
    • As a german you should stfu and mind your own business looking for the uncle in Argentina

      @TheLukaszpg@TheLukaszpg10 ай бұрын
  • yeah the real benefit of over sized conduit you only have to dig once , you only buy it once and , its not much more expensive unless your going ginormous. yeah especially when your running thhn wires. its a few bucks more but if you run power tools you'll be quite happy

    @luvdady@luvdady9 ай бұрын
  • Hi April, long time no post, huh!? Don't mistake me for not posting that often anymore, has nothing to do with your videos or the content! No, quite the opposite, I watch all your videos! I liked especially the one when you collaborated with Tim Allen and Richard Karn on "Assembly Required"! Keep up the great work! Oh, and I definitely like the "Good Bye" wave with your hand/arm at the end of every video!

    @Marcus_Aurelius_1978@Marcus_Aurelius_197810 ай бұрын
  • Hi

    @nbkifph@nbkifph10 ай бұрын
  • Most conduit is NOT watertight!

    @mobeydick37@mobeydick3710 ай бұрын
  • Meh, much prefer to use PVC jacketed MC for the task as it provides for a much more robust cabling solution and it cleaner looking. Not a fan of UF after all the repairs I ave had to do over the years.

    @mikeiver@mikeiver10 ай бұрын
  • Exterior receptacle "water resistant?" Weather proof junction box with conduit to nowhere!

    @uhjyuff2095@uhjyuff209510 ай бұрын
  • THANKS APRIL , boring yes … still better and faster then a hammer and the star drill😅😂

    @budgetaudiophilelife-long5461@budgetaudiophilelife-long546110 ай бұрын
  • nice installation, I noticed your garage's conduit is pvc, by code you're not supposed to use pvc indoors, the conduit is toxic in case of a fire can harm people with the fumes.

    @josemarin7913@josemarin79139 ай бұрын
    • Jose, can you provide the NEC# regarding this? Thanks.

      @rosewoodsteel6656@rosewoodsteel66565 ай бұрын
  • What’s for dinner

    @homayounsolaimani8856@homayounsolaimani885610 ай бұрын
  • Actually, water and electricity mix just fine with one another. It's just when you start diluting that mixture with other organic materials (namely ones that require a heartbeat and oxygen for optimal continued performance) that the problems begin.

    @bunnyultima1875@bunnyultima187510 ай бұрын
    • The trouble begins when there are dissolved minerals in the water. There are always dissolved minerals in natural water sources. Please take your foolishenss somewher else.

      @kmoecub@kmoecub10 ай бұрын
    • @@kmoecub no.

      @bunnyultima1875@bunnyultima187510 ай бұрын
    • ​@@kmoecubWhoosh

      @cuebj@cuebj10 ай бұрын
  • Actually, water and electricity mix really well. That's the problem.

    @robtk3@robtk310 ай бұрын
KZhead