Would you use a WAGO 221 CEILING ROSE?

2024 ж. 1 Мам.
67 301 Рет қаралды

Screwless terminals such as the Wago 221 are popular with UK electricians. We also see screwless terminals in LED downlights. So why has no one launched a WAGO connector based ceiling rose?
As ever eFIXX love to help bring new products to market which make electricians lives easier. This prototype ceiling rose using Wago connectors turned up at the studio so we decided to test it out.
== 🕐 Time Stamps - Cut to the action 🕕 ==
00:00 Electricians’ - would you buy a screwless ceiling rose?
01:18 WAGO ceiling rose prototype.
02:20 Screw-less terminals are popular on downlights
03:15 Gary tests out the WAGO ceiling rose prototype
07:24 Challenges with this prototype design
07:59 Could this be supplied as a chassis only?
08:40 The BIG question - would you buy one and what price?
== AD ===========================
🧰 More WAGO videos by eFIXX
efixx.co.uk/wago​
🧰 Stock up on your Wago connectors
👉 Wago L-BOXX KIT
hub.efixx.co.uk/wago-lboxx
Wago 221 - 2 way hub.efixx.co.uk/wago221-2
Wago 221 - 3 way hub.efixx.co.uk/Wago-221-3
Wago 221 - 5 way hub.efixx.co.uk/Wago221-5
================================
📍SUBSCRIBE TO THE CHANNEL
eFIXX is here to help electrician's, electrical contractors, building services engineers and electrical apprentices. Watching our videos, you'll discover new products, explore new applications and find answers to your technical questions. So if you've been on the tools for years or just starting your electrical journey, we'll help you stay up to date with the latest regulations and developments in the electrical industry.
hub.efixx.co.uk/youtube-subscr...
================================
📺 NEW TO THE EFIXX CHANNEL Watch our essential videos playlist
hub.efixx.co.uk/essentials​
📺 CATCH UP ON THE LATEST VIDEOS
hub.efixx.co.uk/latest​
📺 ELECTRICIANS' TOOL REVIEWS
hub.efixx.co.uk/tools​
================================
🔴 eFIXX LIVE
Join us for our youtube livestream twice a month - features product sneak peeks, challenges, giveaways and live electrical banter.
NEXT STREAM HERE
👉hub.efixx.co.uk/next-live-stream​
Catch up on previous episodes
👉hub.efixx.co.uk/livestream​
================================
🆕 FREE CPD
Learn about new applications, regulations and best practice with our FREE CPD modules. - New modules released every month covering everything from surge protection to lighting
hub.efixx.co.uk/CPD​
================================
📝 APPRENTICE HUB If you're an electrical apprentice, retraining as an electrician or looking to refresh your knowledge, then please check out our apprentice hub. It contains thousands of multiple-choice questions to help prepare for electrical installation exams.
hub.efixx.co.uk/apprentice​
================================
📩 eFIXX NEWSLETTER Sign up to find out about our live events, competitions and product giveaways.
www.efixx.co.uk/sign-up​
================================
FOLLOW US on your favourite social networks for behind the scenes action, breaking news and competitions.
🟠 INSTAGRAM hub.efixx.co.uk/Instagram​
🔵 LINKEDIN hub.efixx.co.uk/linkedin​
🟣 FACEBOOK hub.efixx.co.uk/facebook​
🟡TWITTER hub.efixx.co.uk/twitter​
==================================
❌ This content on this channel is for electrical professionals.❌ ==================================
📹 Presented by
Gary Hayers - Editor eFIXX
Gordon Routledge CEng MIET - Technology Editor eFIXX
===================================
#efixx​ #wago​ #connectors

Пікірлер
  • Anything Wago I’d use without hesitation. I’m glad they’re getting their feet more firmly in the market.

    @cypeman8037@cypeman80373 жыл бұрын
    • +1

      @stuartandrews4344@stuartandrews43443 жыл бұрын
    • Agreed!

      @tuboid001@tuboid0013 жыл бұрын
    • Amen 😎👍

      @nomorefaith4988@nomorefaith49883 жыл бұрын
    • @balls up You're silly.

      @cypeman8037@cypeman80373 жыл бұрын
  • I think the majority of electricians would to be honest . Convenience , consistency of terminations and of course time . Time is everything, it’s a winner for me .

    @MizunoIronMan@MizunoIronMan3 жыл бұрын
    • Thanks for a great comment

      @efixx@efixx3 жыл бұрын
    • Cost is the drawback, electricians use whats included in a light kit.

      @shadowopsairman1583@shadowopsairman15833 жыл бұрын
  • Great no more swearing at those terminal screws that like to round off or crack the casing with the screwdriver I'm sold on the idea

    @andrewyeo2818@andrewyeo28183 жыл бұрын
    • Thanks for your feedback

      @efixx@efixx3 жыл бұрын
  • Would love to see more electricians using more suitably size earth sleeving as opposed the generic 3mm stuff. On ceiling roses or down lights using 2mm sleeving just gives for a neater job

    @bourneelectricalable@bourneelectricalable3 жыл бұрын
    • Amen to that. Barely use the horrible stuff.

      @jameshansing5396@jameshansing53962 жыл бұрын
    • Be even nicer if the CPC was already insulated!

      @iantaylor6538@iantaylor6538 Жыл бұрын
    • @@iantaylor6538 I seem to remember it’s by design, not cost, that it isn’t.

      @GrahamDIY@GrahamDIY Жыл бұрын
  • Screw-less terminations have to be a good thing. For connection quality consistency.

    @michaelgorman1359@michaelgorman13592 жыл бұрын
  • I don't loop in at roses anymore, I do all my connections in wago box with a fly lead out to the rose with a single cable, makes it future proof and a lot easier to fit modern flush mount light fixtures

    @lunavx@lunavx3 жыл бұрын
  • I generally use MK pendant sets these days, the helpful features for me are 1) clear base 2) inclusion of a little bit of sleeving in the pack 3) metal surround for bayonet lamp to hook onto. MK sell them in sealed plastic bags which is a good job as at least one of the terminal screws has usually shaken out in transit. Used to paying £2-£2.50, if it comes with the above features and 221's fitted (1x 2way 2x 3way, 1x 5way) I'd be happy to pay £35 for 10

    @dg2908@dg29083 жыл бұрын
  • I'm hoping Wago takes over the world . best thing invented ,since a slice of bread 🍞

    @FNUKSTER1366@FNUKSTER13663 жыл бұрын
    • Best thing since copper wire

      @misstakenot9582@misstakenot95823 жыл бұрын
    • I used to work at the bakery where they invented sliced bread. When the showed the MD he said " Wow this is the best thing since, erh, erh erh"

      @billdoodson4232@billdoodson42323 жыл бұрын
    • Until we find out that the plastic hardens through constant heating and cooling leaving dangerous “maintenance free” connections.

      @toddbod94@toddbod942 жыл бұрын
  • This is way of the future, and to be encouraged. Well done guys.

    @davidpatterson1574@davidpatterson15743 жыл бұрын
  • Cool, I’d use one in the right situation. I use the quickwire method a lot, good if they could do one with a three core fan option too for above a bathroom.

    @dadskillz@dadskillz3 жыл бұрын
  • My first thought from the thumb nail was "how do you get a 4th cable in there" Nice to know you addressed it as "Not possible yet"

    @ColinRichardson@ColinRichardson3 жыл бұрын
  • As someone who hates the awkwardly angled terminals with no decent plastic molding to guide the screwdriver on a lot of ceiling roses, I like this idea very much. Generally on most new places I wire I take feeds to the switches and have 47mm boxes, as often end up having to fit flat plates with dimmers, and most of the designer lighting that gets specified barely has the capacity to house 1 cable. I would imagine anyone coming along to replace one of these with a decorative fitting would probably just pull the wagos out of the molding and house them in the base of the new fitting, which is far better than the old DIY trick of busing up the plastic on a ceiling rose and taping up the exposed brass terminals.

    @_______DR_______@_______DR_______3 жыл бұрын
    • I have seen that way to many times , bits of sellotape around the bare brass terminals and jammed into an ikea light fitting.

      @dennisphoenix1@dennisphoenix13 жыл бұрын
  • Crabtree used to have switches with pushin terminals, we fitted thousands for Norwich City Council. Would be great to see more accessories with push fit.

    @100tinsoldiers@100tinsoldiers3 жыл бұрын
  • totally depends on the situation, design, customers need/wants and costs. but id use these in a heartbeat.

    @denbo786@denbo7863 жыл бұрын
  • Would love to see something like this on a shower isolater.

    @erenhoussein2077@erenhoussein20773 жыл бұрын
    • 👊

      @efixx@efixx3 жыл бұрын
    • 🤣

      @vitorplo2109@vitorplo21093 жыл бұрын
    • 😳

      @nickmurphy6515@nickmurphy65153 жыл бұрын
    • That would be a fire safety precaution upgrade.

      @jontownsend8090@jontownsend80903 жыл бұрын
    • Clock Scolmore are my no. 1 shower pull cord. Take a look. Revolutionised it for me

      @oscard-1863@oscard-18633 жыл бұрын
  • Would definitely use them. To many years mucking about. Loved it when pre wires lamp holders came in. Although I am able to strip flex quicker than my younger colleagues 😄

    @Charleighcharger@Charleighcharger3 жыл бұрын
    • Thanks for commenting 👍

      @efixx@efixx3 жыл бұрын
  • Love it, I'd hope it was circa £3 plus connectors. If you made enough they could be that price and they would take over. I'll buy x 20 right now. 👌

    @ratsalive@ratsalive3 жыл бұрын
  • I would think by using the wago connectors you could only improve the circuit connection. Potentially resulting to a reduction in termination faults

    @craigbuist4636@craigbuist46363 жыл бұрын
    • Let’s hope so

      @efixx@efixx3 жыл бұрын
  • Push in connectors would be amazing to use as standard. I’ve often had to install 20 Down lighters in a room, fingers ache after a day of wrestling cables

    @JDAfrica@JDAfrica2 жыл бұрын
  • About time we got rid of those daft little screws where the end gets gnarled, thread strips and you always end up dropping one, NEVER to be seen again. Wago, quick, convenient, flexible and so much more adaptble for future configurations

    @sygad1@sygad13 жыл бұрын
  • Would like to of seen you put the whole pendant up to see if the cpc terminal fitted under the screw on cover because it looks like it protrudes down a bit to far but still a great idea👍

    @nickmurphy6515@nickmurphy65153 жыл бұрын
  • The industry needs this but I also need this it's magic

    @CJD1579@CJD15793 жыл бұрын
  • Brilliant idea, makes fault finding soo much easier.

    @Nisar1193@Nisar11933 жыл бұрын
    • 👍

      @efixx@efixx3 жыл бұрын
  • Yes and Yes. While you are in a roll with Wago - can you do a session on mounting frames for Wagos, boxes for mounting them in and the Wago din rail mounted stuff - with part numbers of course.😉

    @normanboyes4983@normanboyes49833 жыл бұрын
    • I can help you with this if you want.

      @daviddraper9256@daviddraper92563 жыл бұрын
  • For older installations in changing just a couple of pendants possibly where there are doubled up terminations I cant see the wago pendant being any benefit but for new installs and multiple pendants fitted it could well save time and possible money over the time saved.

    @paultipton743@paultipton7433 жыл бұрын
  • Great Video lads, with more and more smart switches,kinetic etc,becoming more popular,I think two plate is going to be the norm for lighting.It would be a quick second fix on a new build,but they would probably be replaced.

    @peterjones9784@peterjones97843 жыл бұрын
  • I was looking for something like this the other day. I'm dying for this product.

    @josephkaz9093@josephkaz90933 жыл бұрын
  • This is genius. Love it.

    @darraghfinnan3740@darraghfinnan37403 жыл бұрын
  • I would argue that anything that increases 'first time right' is a good thing. The current issue in big builds is that the installer at 2nd fix doesn't often test it, and so has no incentive to get it 100% right. One single fault is a real pain to find and fix. How many housebuilders DON'T have a wiring issue reported as a snag by either the person testing/inspecting, or (and we hope not this late) by a new house owner? Wago 221s are a godsend. Period. In a socket? Yes please, yesterday. The same goes for light switches. My view is that the 221s should be in the pattress though, NOT the face plate (as you glued them). So, the socket would need to have fly leads to link to the 221s, which means a 4 way 221 would be needed (ring final [2] PLUS spur plus fly lead). In effect, if you look at how a commercially installed socket is done in the USA, they now tend to have a fly lead on the socket to link to a 221 (or equivalent) where all the wiring comes in/out. Take a look at this Spelsberg junction box from CPC: cpc.farnell.com/spelsberg/80680701/ip65-grey-junction-box-screwless/dp/EN85174. That is in production already. The connection block at the top unscrews and comes out. Genius. In a pattress, you could fit the wires to the 221s, slot them in to the carrier, screw that in, introduce the socket fly leads, fit the socket to the pattress.

    @trevornelmes9331@trevornelmes93313 жыл бұрын
  • Love this. I would use them every where. Save labour time.

    @electrician247@electrician2473 жыл бұрын
  • Speaking from a Customer/Consumer Point of View I think these would actually increase safety as this would mean that customers who self install these pendant roses would not need to spend more time on step ladders than what they would need to do if they were to screw them in. Secondly I think having this for the trade would mean that as customer I would know that in less than 10 mins my electrician I contract to carry out the works would charge me less or be able to carry out more install's in my property within the 1 hour hourly rate! Saving me time, money and the contractor their time too! I think screwless sockets and light fittings are the way to go as I would feel safer knowing the terminations have been made correctly to the right tightness and it would avoid arcing and sparking!

    @bryceonyoutube@bryceonyoutube3 жыл бұрын
  • This is a great initiative guy wow, no one saw this coming but Efixx saw it from far and today here we go, I love it. Where can we find it?

    @triplerjm2353@triplerjm23533 жыл бұрын
  • Wow - I love Gaz great work 🦾

    @vievlogs589@vievlogs5893 жыл бұрын
  • My wife is getting very worried about my increasing over-excitement about the ever increasing choices in WAGO products. I need to get out a bit more. 😆 A very good video to watch.. You boys always produce top stuff... Thanks. 👍

    @christopliss9947@christopliss99472 жыл бұрын
  • Yes please. Get them on the market ASAP.

    @lidayjuraj@lidayjuraj3 жыл бұрын
  • I've always thought why has nobody thought about this before. Obviously would depend on the cost.I would happily pay an extra quid for the ceiling roses with screwless terminals. Anything that would save time. I think the CPC can stay as screw with one terminal. So a hybrid version.

    @AhmedMohammed-jv6sr@AhmedMohammed-jv6sr3 жыл бұрын
    • Great comment 👍

      @efixx@efixx3 жыл бұрын
  • Like a work of art 👍🏻👍🏻👍🏻👍🏻

    @smcomputersolutions@smcomputersolutions3 жыл бұрын
  • I like a good wago. I would probably use these to be honest. The screw terminals in the current versions, from many different brands are just not up to scratch.

    @petertallowin6406@petertallowin64063 жыл бұрын
  • That would be an improvement even for Germany. Now there are always three cables hanging from the ceiling, black, blue, yellow-green and a hook. A plastic cap is pushed over. With every new lamp these cables get worse. And if these cables are then cast into a concrete ceiling, then you cannot change them. (Saved on the flexible hose during construction, cost cents). 221 are also easy to clamp on a ladder. Notice: The cables are clamped in boxes in the wall if old or new behind the switch.

    @jensschroder8214@jensschroder82143 жыл бұрын
  • These are brilliant! Would definitely use them!

    @TheAdamEdward@TheAdamEdward3 жыл бұрын
    • 👊

      @efixx@efixx3 жыл бұрын
  • Wago and Quinetic = DIY bliss.

    @garyredmond1890@garyredmond18903 жыл бұрын
  • Whilst the ease of fitting is good, for me the big draw the confidence in the clamping of the wire. Most basic roses use the end of the screw to clamp rather having a pressure leaf to spread the clamping force.... time and time again I come across either loose or over-tightened resulting in broken conductors. The other big bonus is 1 wire 1 terminal, no twisting together etc.

    @farmersteve129@farmersteve1293 жыл бұрын
  • Yes would use them, even with being a bit more expensive say around £3.50(bulk)-£5 as standard rose start £1 the wagos 30p each. Like the guys said it would be good to have a rose without connectors which would be cheaper as I carry a selection of wago's in the van anyway.

    @Electronics-Rocks@Electronics-Rocks3 жыл бұрын
  • I hate working above my head so this seem like it would help.

    @jondonnelly4831@jondonnelly48313 жыл бұрын
  • In new builds these would be used, then within a year or two many of them ripped out for aesthetically pleasing light fittings. So, those push fit lighting j-boxes would be used shoved into the ceiling space. I only have one ceiling light fitting in my place - a very expensive pendant light over a dining table, which does not use a standard ceiling rose.

    @johnburns4017@johnburns40173 жыл бұрын
  • Hi, Just a thought. As modern smoke alarms are fed from the light fittings. Has this rose got a seperate set of wagoe's for this or do you just double the smoke alarm feed wires into the same terminals?

    @billsbasementworkshop1902@billsbasementworkshop19022 жыл бұрын
  • Instead of fiddling with both the diagonal cutters and the big wirestripper tool during the install, you could have used a cable cutter. The CC22 is the go to here in the nordic countries. It has a cutting area made specifically for stripping wires.

    @aDanishDude@aDanishDude2 жыл бұрын
  • Ktech makes the “mbox l32” which is sold in various locations. Sold as a wiring centre but can be good for other complicated set ups with multiple switches for bathrooms etc. Ktech has, for years, had “kRose” as an upcoming product but it isn’t yet in the market. I don’t know but I always assumed it was a wago based ceiling rose. They’re very local to where I work so hopefully the prototype you have is from them. Wagos beat screw terminals for me every time!

    @paulharrison2325@paulharrison23253 жыл бұрын
  • Again, something like this is a #gamechanger. It would certainly stop people balancing on a ladder tightening little screws with various different tightening tools. They'll have to be cheap for people to start using them. Great video guys.

    @JBE@JBE3 жыл бұрын
    • Thanks 👍

      @efixx@efixx3 жыл бұрын
  • I would use them all day long compared to the screw version,and fault finding would be made easier too,do love an mk ceiling rose too❤️

    @johncoombs3128@johncoombs31282 жыл бұрын
  • Hell yes. Tiny Screw terminals are so sharp they make it really easy to cut through a 1.5mm cable. How many times have I have to re-terminate the cable cos I’ve chopped through it cos I do the screw up too hard..... Your prototype is thicker ‘cos the wagos are at an angle. Could be thinner by laying them flat, at the risk of having to be a larger diameter. But that layout isn’t required... would a north south east west layout allow you to keep the same diameter?

    @jeffmoye@jeffmoye3 жыл бұрын
  • Hi chaps, love the idea and wago. Do you rawl plug your ceiling roses. So many are fitted badly without them and just in to the plasterboard. I always use rawl plugs and I’m forever fixing loose ceiling roses because sparkies don’t fit them well.

    @jamesnorris9816@jamesnorris98163 жыл бұрын
  • Great idea, it all comes down to cost though. Maybe the connections used in the F type downlight could be the way forward to bring the price down?

    @stokiesparky2790@stokiesparky27903 жыл бұрын
  • Yep. Great idea, just needs making as a non-prototype version now.

    @daveys@daveys3 жыл бұрын
    • True

      @efixx@efixx3 жыл бұрын
    • Be a great one for Deborah Meaden on Dragons Den ..

      @LDaQuirm@LDaQuirm3 жыл бұрын
  • Is there anything to stop roses being bigger, with more space for more connections or even a junction/adaptable box with a flex outlet? How about using the push button (Ashley box style) like on your downlighter review? I'm a huge fan of Wago but we're yet to get the full potential. New light fittings with them in place? No more balancing a light on your head while you hold multiple cables into a connector block & twist the screwdriver with you teeth!

    @brianmac001@brianmac0013 жыл бұрын
  • One recommendation I would make is that Waco could colour code the orange keys in brown, blue and brown/white stripe (switch live)

    @vw663@vw6633 жыл бұрын
    • That would be good however then you need to buy 3 times the amount of wagos and not being that cheap just adds to the cost which in turn reduces profit.

      @theoriginaldjprism@theoriginaldjprism3 жыл бұрын
    • Just add little stickers as standard with each one.

      @roberthardy2013@roberthardy20132 жыл бұрын
  • Having these would've been awesome last week. where are these from?

    @adamhill1627@adamhill16273 жыл бұрын
  • Excellent. Thanks.

    @fje1948@fje19483 жыл бұрын
    • 👍

      @efixx@efixx3 жыл бұрын
  • Wagos all the way personally Id expect these to be on all accessories where practical within the next 2 years

    @iknowmyfootball3901@iknowmyfootball39013 жыл бұрын
    • Let’s hope so 👍

      @efixx@efixx3 жыл бұрын
    • The thing that stands to me regardless of experience and believing that we can make a sound connection everytime at the optimum torque realistically we can't , I am really pushing for our contractors to use products like these on new builds

      @iknowmyfootball3901@iknowmyfootball39013 жыл бұрын
  • Time saved installing but time lost testing/FF. Not sure if 221 comply with GS38 because I have found my megger probes are far to small to perform tests.

    @silversurfer50001@silversurfer500013 жыл бұрын
  • HI, what is the wire stripping tool you use, thanks for a great channel

    @andystanton2577@andystanton2577 Жыл бұрын
  • 1st question - yes, 100% I would use one, I hate ceiling roses 2nd question - if I was doing a rewire I will never take the feed to the ceiling rose so wouldn't need as many connectors, I would pay around £2.50 for it. I can't quite think why but I think this video is once of the best you've done, nudge nudge, wink wink!!

    @DoctorElectricYouTube@DoctorElectricYouTube3 жыл бұрын
    • how would you do it then? Would you feed the mains through the switch then the switch on to the pendant? I tried that and it keeps tripping...I tried it the normal way too and the same again. Only one of the ones I'm doing that's doing this at present...really frustrating!

      @weedfreer@weedfreer Жыл бұрын
    • @@weedfreer Take the permanent line to the switch, then the switch line up to the pendant, the return from the switch line is connected to the Neutrals in the back of the backbox, pretty common setup to be honest, can't believe you've not seen a feed to switch before

      @DoctorElectricYouTube@DoctorElectricYouTube Жыл бұрын
    • @@DoctorElectricKZhead I have...that's the point. I've wired the rest of this section up like this going via LED downlighters just fine. I think either I have a cable issue here or the fitting needs replacing personally. I've even attempted to set it up as per usual standard by putting a permanent feed into the rose and then running through the loop block to the switch and then into the bulb's live terminal and it's still failing 🤔 I've replaced the cable from the switch up inside the wall also already for new (although, I may do it again using 3 and earth so I can leave a neutral there in case I may want to get some fancy smart switch later on)

      @weedfreer@weedfreer Жыл бұрын
  • May be a silly question, Can we use 3 way connector where there are only 2 connections and the 3rd slot keeps empty in the wago? Does that makes any safety issue? Thank You

    @shinekthomas1979@shinekthomas1979 Жыл бұрын
  • This would be something I use when replacing exsisting lights, but considering as an industry we are moving towards wiring our loop in and out at the switch instead of the light I don't see wago bothering to manufacture these. Then again I could be wrong, it's been known to happen 🤷🏽‍♂️

    @tarodchaoslord@tarodchaoslord3 жыл бұрын
  • 2 things missing!!! 1. Exposed recessed conductive parts to allow testing without removing the conductors. 2. Intumescent pad

    @MrSJT@MrSJT3 жыл бұрын
  • as a yank, we'd dustbin the ceiling rose. we prefer to have a 3 and 5.8" round box recessed into the ceiling, and then any surface mounted light will screw to that box. also, we've been feeding the power through the switch box for many years now, and most of us prefer it that way, because it eliminates using a color of conductor for a different purpose than the color code implies. as for the Wagos, I don't trust screwless connections for power going through, because we have had screwless receptacles for years, and they're a bit rubbish. I'd estimate I see between 10 and 20 screwless connections fail for every mechanically fastened connection that fails. fixture connections, I don't mind so much, because they don't carry as much amperage and they don't black out half a circuit if they go bad.

    @kenbrown2808@kenbrown28083 жыл бұрын
  • i would pay more for screw terminals, push fit is a pain in the arse for testing, yes they put a tiny hole for testing but i have yet to see a test lead that fits in the hole.

    @ShadowzGSD@ShadowzGSD3 жыл бұрын
  • Hi fellas, love your stuff, very educational, thanks, but I do have a question regarding BS1363 design, I recently had some 2 gang TCP Smart sockets with wifi app controllable switching, all good except the two earth connection points on the outlet were not inter-connected, and I was concerned that the average DIYer swapping these out may not realise that they could break the continuity of the earth ring if they added more than one of these, do you know if the standard specifies that sockets should have internal connection between earth terminals? as I believe this could be putting people in danger of not having earth fault protection. Thanks.

    @AdeSwash@AdeSwash3 жыл бұрын
    • Send us a link to the product or a photo and we’ll take a look. TCP have a track record in electrocution- www.luxreview.com/2015/03/12/led-lamp-shocks-bulb-tester-at-uk-consumer-publication/

      @efixx@efixx3 жыл бұрын
    • @@efixx for some reason my link gets deleted by youtube, so go search for 'TCP Smart Wall Socket with USB' sold on ebay by a big high street catalog shop ;)

      @AdeSwash@AdeSwash3 жыл бұрын
  • Would love to see it become standard to loop at the switchesand no longer use ceiling rozes point blank as it is a nightmare with most light fixtures 😃

    @erlwindegans3954@erlwindegans39543 жыл бұрын
  • The option to buy just the basic model and upgrade it yourself with additional wago's would be IMHO the way to go, this will keep the initial cost down, allow 1 model to be bought in bulk yet can fit multiple situations. As long as the std wago can be fitted. Not to forget wago clones, the other brands that make the same thing - can some of those fit too?

    @mattylad8035@mattylad80353 жыл бұрын
  • If the choice was between a ceiling rose with screw terminals and one with WAGO terminals I would opt for the WAGO. But there are a few issues we should think about when we talk about WAGO type ceiling roses. The first is cost, a screw terminal ceiling rose is fairly cheap to buy so must be cheap to manufacture and a WAGO one may not be able to compete on price particularly in a market which is shrinking. As a personal example of this I had a look around my own house, when we moved in a long time ago we had 13 ceiling roses in total. Now we have only 7 ceiling roses and 11 other light fittings which I cant call a ceiling rose as they fit directly to the ceiling and over half of them have multiple GU10 LED bulbs on a bar. These light fittings have push in type terminals in the base of them, some even have multiple common terminals to allow loop in etc. So I think the days of the traditional ceiling rose are numbered, a lot of new houses have LED downlighters everywhere.

    @davidcooke3081@davidcooke30812 жыл бұрын
  • Good idea but no can’t help thinking that in a couple of years we will have to resign our screwdrivers to a box in the under the stairs or the bin, and any jo blogs can do there own electrical work and won’t need us , other then to put there cockups right and make safe. So no I won’t be using them. Great video guy’s as always 👍👍❤️⚡️

    @Dog-whisperer7494@Dog-whisperer74942 жыл бұрын
  • I think WAGO connectors are great for lighting circuits. Not totally sold on the idea for use on higher currents. When will we be able to buy the WAGO ceiling rose?

    @mrelectronicsdude@mrelectronicsdude3 жыл бұрын
  • Wago's are the way to go, brilliant idea. ⚡

    @Steve-ho4pq@Steve-ho4pq3 жыл бұрын
    • 🦾👍

      @efixx@efixx3 жыл бұрын
  • Nice video, Don't think that they have any place in the modern home. Would be a thing for a new build, but many of my cliens contact me to change the pendant for a more decorative fitting. Maybe the construction company should put roses in and not the pendant, that way the person buying the house can have a choice of light fixtures. I have quite a lot of pendant light fittinge which I have kept ( Just in case anyone needs one replacing ) But to my knowledge no one does.

    @billsbasementworkshop1902@billsbasementworkshop19022 жыл бұрын
  • To overcome additional feeds why can’t we have two conductors into one terminal. If a 221 is rated up to 4mm. 1+1 is 2 and 1.5 + 1.5 is 3 for lighting wires. I have seen many others do this. Is this a problem?

    @KevinGarcia-yp5rk@KevinGarcia-yp5rk3 жыл бұрын
    • They can only properly grip one wire, particularly if it's solid core you can get away with multiple stranded wires in one terminal but I only do that on SELV temporary stuff, not a good idea in a permanent mains install.

      @mfx1@mfx13 жыл бұрын
    • @@mfx1 for multistrands use proper ferrules /reducers for the required size with a crimp.

      @sriyantra1939@sriyantra19393 жыл бұрын
    • @@sriyantra1939 Maybe for a single stranded wire, but that wouldn't work well for trying to more than one wire ion one terminal as there's a good chance one won't end up being gripped properly, also ferrules are not strictly needed or even always desirable for spring clamp terminals like Wagos, only for screw/cage clamp ones although many people prefer it, that's up to them.

      @mfx1@mfx13 жыл бұрын
  • Where can i buy them!

    @Harrycowlton@Harrycowlton7 ай бұрын
  • What about having the ceiling rose fix to a plasterboard ceiling similar to a plasterboard back box.

    @londontrada@londontrada3 жыл бұрын
  • Tbh wiring up a standard pendant batten isn't that hard only that as you pointed out the terminals are smaller than standard terminal driver and makes difficult to tighten. They could just make pendants etc slightly bigger and accommodate extra terminals . But I guess as more people use the feed to switch method you dont need that many terminals

    @theoriginaldjprism@theoriginaldjprism3 жыл бұрын
  • Yes I would. Good video as always. I’d pay about £10 for one . Especially if you have to go back and replace the light for different one in the Future

    @thomfoun@thomfoun3 жыл бұрын
    • 👍

      @efixx@efixx3 жыл бұрын
  • Yes they would be a great asset

    @malcolmbarker4862@malcolmbarker48623 жыл бұрын
  • You had me at Wago. Great gear and a doddle to install. Stops your average punter from killing the terminal screws as well

    @gordon_jilks@gordon_jilks3 жыл бұрын
  • Oi… Any update on when/if/why not, these will be available?

    @robwilton8001@robwilton8001 Жыл бұрын
  • have a look at LK's roses, they are made for 5 lead wires instead, seem more roomy with better cable retention

    @Skjaeg69@Skjaeg693 жыл бұрын
    • ? LK, is that the name of the manufacturer or the seller ?

      @oldbutstillcurious3615@oldbutstillcurious36153 жыл бұрын
  • I asked MK for a WAGO Mains Socket 10 years ago… Definitely time now for Mains Supply and Ceiling Roses using WAGO. Any suggestions for an existing WAGO product to supply an island induction Hob (possibly pop up sockets too) using fixed wiring in wall of 4mm2 to the flexi pre-wired to Neff Hob? Typically it’s not long enough to reach the wall… Oh I’d pay £1 for a WAGO ceiling rose, after all if I’m populating it myself with 221’s there would be no metal in it.

    @robwilton8001@robwilton80012 жыл бұрын
  • What call the wires stripper? Thank you

    @ramin2011m@ramin2011m3 жыл бұрын
  • Can you give me a link to downloads WAGO products catalogue in CDS Having one 15 years old so...

    @sriyantra1939@sriyantra19393 жыл бұрын
  • Great idea, i would use, if price was similar to a standard rose and not the usual over pricing by wago.

    @01bystander@01bystander3 жыл бұрын
    • So you want better technology/better safety and reliability/ease of fitting but you dont want to pay for the r&d? Well done

      @andytap560@andytap5603 жыл бұрын
  • Just fitted those f types just looked at them and they were in! Lovely jubly

    @Bambagustrust@Bambagustrust3 жыл бұрын
    • Toolstation!! £12

      @Bambagustrust@Bambagustrust3 жыл бұрын
  • Absolutely.

    @markdaly818@markdaly8183 жыл бұрын
  • The 221s are just awesome. So much easier and quicker.

    @reubenklang3968@reubenklang39683 жыл бұрын
  • Feed through the switch method?

    @johnburns4017@johnburns40173 жыл бұрын
  • So where do I buy these from?

    @Monahmed2086@Monahmed2086 Жыл бұрын
  • Where can I buy I had that idea

    @leighmontero3607@leighmontero3607 Жыл бұрын
  • ABB have a Schuko Outlet that are delivered with screwless connections

    @allaabraham1746@allaabraham17463 жыл бұрын
  • I like the wago cieling Rose, however the only niggle that I have is when performing safe isolation, because with a standard cieling rose you can put your voltage indicator onto the screws to test the supplys dead. With the wago cieling rose you would have to disconnect all the conductors in order to test them, and should the supply be live then you risk getting a shock when disconnecting the conductors. Thats the only niggle I have. Maybe they could make a test area on the wagos for testing the supplys dead with the voltage indicator?

    @planetconker1104@planetconker11043 жыл бұрын
    • Wago 221 and 222 connectors do have a test slot, but sadly at least on the 222s (I haven't tried the 221s yet) it seems to be too tight/deep for the modern high safety rating probes to get into :( I'm also not sure how reachable it would be in that rose design.

      @petermichaelgreen@petermichaelgreen3 жыл бұрын
    • @@petermichaelgreen I've checked the 221s and there's no way of testing them as far as I can see without taking the conductors out.

      @planetconker1104@planetconker11043 жыл бұрын
    • @@planetconker1104 www.wago.com/gb/electrical-interconnections/discover-installation-terminal-blocks-and-connectors/221 claims there are test slots, but it looks like you need a pretty long thin probe to get into them.

      @petermichaelgreen@petermichaelgreen3 жыл бұрын
    • @@petermichaelgreen Well I've got a bag of 100 2.5mm² 221s and a mixed box of different sized 221s and I cant see any where for probes to go.

      @planetconker1104@planetconker11043 жыл бұрын
  • Sooner everything has Wago connectors or similar the better. Sockets, switches and lights. Everything looks neater and better with the smaller 2mm sleeving as well. Sooner we use the same sort of T&E that they use in Ireland the better, no sleeving at all then. Just as a matter of interest do you know if it is possible to use it in the UK or does it not meet our specs? www.screwfix.ie/p/prysmian-n05vvh4-u-grey-2-5mm-twin-earth-cable-100m-drum/226hk

    @billdoodson4232@billdoodson42323 жыл бұрын
    • Came across a house wired in this a while back, guy was from ireland and had his sparks come over n wire the house. Perfectly fine as it meets the minimum requirements, as long as it's the correct cores csa/colour and material used it's not an issue.

      @effervescence5664@effervescence56643 жыл бұрын
    • Agree with you on this. The amount of time I spend faffing around sleeving things.

      @josephkaz9093@josephkaz90933 жыл бұрын
    • you can use it in the UK as long as it's sized for the amperage correctly iirc

      @BenCos2018@BenCos20183 жыл бұрын
  • I would say that this would be a staple for me, not because of anything else other than the fact the quality of the screw terminals nowadays are terrible, I’d rather pay the extra quid more to use these 100%

    @user-wc1nd9ie6x@user-wc1nd9ie6x3 жыл бұрын
  • Funny I did this just the other day!

    @stefanjoyce2776@stefanjoyce27763 жыл бұрын
  • I’d expect these to be a similar price. I’d just have them without the connectors so all plastic. That should reduce the price of manufacture. Then supply your own wagos. We’re doing lots of properties and getting 7 pendants up over 30 flats soon adds up time and money wise

    @lefty8493@lefty84933 жыл бұрын
KZhead