EARTH LEAKAGE - REAL LIFE EXAMPLE

2023 ж. 20 Қыр.
14 827 Рет қаралды

No need for fancy intros….
No need for fancy graphics….
No need for clickbait….
No sponsorship….
Everything you see i have purchased myself, this gives me complete control to voice my honest opinion about any product
Just day to day sparky videos
If you like it, that’s cool, if you don’t, that’s cool as well.
Remember, context is important, I can’t show/film every part of every test otherwise I’d still be there now😂just assume I’ve carried it out correctly

Пікірлер
  • I like the way that we are required to use metal CU's but its OK to stick them in a lovely flammable cabinet!

    @icarossavvides2641@icarossavvides26417 ай бұрын
  • Did you ramp test just the rcd with no load on it? If load still on then existing leakage could effect ramp test reading?

    @OptiJack@OptiJack7 ай бұрын
  • Even as a non electrician earth leakage faults have driven me insane more than once, when you have isolated every appliance in the kitchen, unplugged everything only to find a pet has pissed on an extension lead behind a settee.

    @g0fvt@g0fvt7 ай бұрын
    • 😩😩😩

      @bristolsparky@bristolsparky7 ай бұрын
    • could you not smell it 😂😂😂

      @Davidhughes9467@Davidhughes94674 ай бұрын
    • @@Davidhughes9467 sadly not, or more accurately they do it somewhere else as a distraction...

      @g0fvt@g0fvt4 ай бұрын
  • RFI filters in all the electronics take up to 1.6mA each, eg Computer + 2 display units, set top box + TV, that's 5 straight off.

    @philipoakley5498@philipoakley54987 ай бұрын
  • Good video to see mate. Informative for someone like myself still learning 👍🏻 always good to see somone break things down while having a little laugh 👍🏻😅

    @louissmith5203@louissmith52037 ай бұрын
    • Thanks 👍

      @bristolsparky@bristolsparky7 ай бұрын
  • Isolate the board and check again. Could be diverted neutral current from another property?

    @HenryOCarmichaelSmith@HenryOCarmichaelSmith7 ай бұрын
    • Already checked, It’s not diverted neutral current

      @bristolsparky@bristolsparky7 ай бұрын
  • Very informative video-thankyou

    @davidpatterson1574@davidpatterson15745 ай бұрын
    • Glad it was helpful!

      @bristolsparky@bristolsparky5 ай бұрын
  • Great.. so easy Ill happy help you

    @Rossisearle@Rossisearle7 ай бұрын
  • Went to a property were the down stairs lights worked with the neutral meter tail sisconected and all earth conductors disconected.

    @lansdorf@lansdorfАй бұрын
    • Ok

      @bristolsparky@bristolsparkyАй бұрын
  • Probably find the immersion heater will dump a few mA into earth when heating the water. Quite common for the elements to get a bit leaky.

    @grahamek86@grahamek867 ай бұрын
    • The immersion is currently a backup & not used so in this instance it was not part of the issue

      @bristolsparky@bristolsparky7 ай бұрын
  • best turn phone sideways

    @JohnnyMotel99@JohnnyMotel997 ай бұрын
    • Nah, it’ll be fine

      @bristolsparky@bristolsparky7 ай бұрын
  • Good video 👌

    @rjkelectrical6086@rjkelectrical60867 ай бұрын
    • Thank you 👍

      @bristolsparky@bristolsparky7 ай бұрын
  • New RCBO board on its way and definitely worth taking a bag of crisps for your trouble 😊.

    @JBE@JBE7 ай бұрын
    • Sounds good!🤌🏻🤌🏻

      @bristolsparky@bristolsparky7 ай бұрын
  • This could be down to defective contacts inside the solar inverter letting excessive current and leakage trickle which is tipping your tolerance over the limit and causing your RCD to trip when the solar kicks in and out primarily in the morning times. How is the inverter fed?…if its SWA cable why is it needing RCD protection on the supply circuit?? Not a solar specialist so i may not be strictly correct but the solar definitely needs checking over. You can swap the board out like you say for an RCBO populated board and eradicate the immediate issue but may still leave an existing problem sitting there undetected.

    @rattlehead85@rattlehead857 ай бұрын
  • Good video As your aware in the regs a 30mA RCD is only allowed 30% which is 9mA so wouldn’t comply. Bad practice putting Solar on a AC RCD shared with other circuits. Would be interested in what the DC leakage was? Obviously not above 6mA as it didn’t blind the AC RCD when testing. I’m looking at getting the TIS 570 AC/DC earth leakage tester to replace my Megger 305E.

    @dmlelectrics8990@dmlelectrics89907 ай бұрын
    • @@Mainly_Electrical Thanks corrected it. My bloody podgy fingers using my phone 😂

      @dmlelectrics8990@dmlelectrics89907 ай бұрын
    • I’m very aware of the current requirements mate👍🏻 it is not my installation, called out to intermittent tripping & have given my professional advice to the client

      @bristolsparky@bristolsparky7 ай бұрын
    • @@bristolsparky I realised it wasn’t your installation mate, I wasn’t being negative? I was just backing you up & adding some facts/figures for others who might be trainees etc.

      @dmlelectrics8990@dmlelectrics89907 ай бұрын
    • @@dmlelectrics8990 👍🏻👍🏻👍🏻

      @bristolsparky@bristolsparky7 ай бұрын
  • Good video

    @sergiofernandez3725@sergiofernandez37257 ай бұрын
    • Thanks

      @bristolsparky@bristolsparky7 ай бұрын
  • I went to a job today with 1.5amps between Line and neutral tails any ideas? split load board intermittently tripping a single RCD

    @joejames8146@joejames81462 ай бұрын
    • Issue somewhere!

      @bristolsparky@bristolsparkyАй бұрын
  • I have the same tester. Do you ever have any issues with it. Sometimes certain applications show massive currents reading which must be wrong be rcd not tripped 🤷‍♂️

    @stevebowley@stevebowley7 ай бұрын
    • Never had an issue with mine

      @bristolsparky@bristolsparky7 ай бұрын
    • I had a issue with mine so i ended up getting the megger one.

      @adoughertycontracting7243@adoughertycontracting72437 ай бұрын
  • Why did you ramp test the RCD with the circuits on ?

    @andrewwhite3793@andrewwhite37936 күн бұрын
    • To prove if it’s weakened under load

      @bristolsparky@bristolsparky6 күн бұрын
  • Did you change the c.u did it solve the issue

    @gd-bq7em@gd-bq7em4 ай бұрын
    • Yes, watch a later video where I change it.

      @bristolsparky@bristolsparky4 ай бұрын
  • Everyone's favourite game 😀

    @user-zl2ow6lo6d@user-zl2ow6lo6d7 ай бұрын
    • Not

      @JimWhitaker@JimWhitaker7 ай бұрын
  • 😅😅

    @Rossisearle@Rossisearle7 ай бұрын
  • next time ya ramp test, turn the circuits off so there is no load through the rcd giving you a more accurate result pal 👍

    @bongyb9407@bongyb94077 ай бұрын
    • Prefer real scenario results but I understand what you’re saying.

      @bristolsparky@bristolsparky7 ай бұрын
  • comprate una pinza de fugas con coneccion bluetooth te ayudaria mucho

    @leevium@leevium3 ай бұрын
    • Nah, that’s OTT, this’ll do just fine

      @bristolsparky@bristolsparky3 ай бұрын
  • Split boards 🤦🏼‍♂️

    @garrygriffithselectricalse843@garrygriffithselectricalse8437 ай бұрын
  • those tester are shit...not reliable....good vid thou

    @dennisfowler-dg5vf@dennisfowler-dg5vf7 ай бұрын
    • I’ve had this one for 4 years and it’s always been reliable

      @bristolsparky@bristolsparky7 ай бұрын
    • mines been giving me reading all along...until i compare it with a more expensive one ...then begin to wonder .... which one is right or wrong @@bristolsparky

      @dennisfowler-dg5vf@dennisfowler-dg5vf7 ай бұрын
  • For full information as well as your videos to give us more benefit Please make videos This video would be more beneficial if made properly

    @mossmm73@mossmm737 ай бұрын
    • Yaaaawwwwwnnnn

      @bristolsparky@bristolsparky7 ай бұрын