CHEAP Electrician cost this customer £1000s💷

2024 ж. 1 Мам.
105 271 Рет қаралды

This is why you should never go for a budget install! Join Lee and Luke as they conduct an EICR and fault-find on a board that's causing some leakage 😨. Dive deep into the process of an EICR and watch the experts in action. I think we can all agree with what Lee said in his rant 🫣.
🧰🛠️ Tool Of The Day 👇
TIS 570 Earth Leakage Clamp Meter: bit.ly/TIS570
💪🏼 Powered by Hilti Nuron - hilti.to/nuron_range
🚨Subscribe to our KZhead Channel for more great electrical content: kzhead.info...
➕Get more from Artisan Electrics here!👇
linktr.ee/artisanelectrics
🔋Use my referral link to purchase a Tesla product and get free credits you can redeem for awards like Supercharging miles, merchandise and accessories.
ts.la/andrew24855
💬Artisan Electric Discord - Join our Electrical Community! 👇
/ discord
🔔 Become a Channel Member To Get Access To Exclusive Perks 👇
➤ / @artisanelectrics
Electricians Business Course
📩 Sign Up To The Electricians Business Course Here And Get The First 4 Lessons Free 👉 ➤ bit.ly/2Z582zI
🔔 Subscribe to TOOLS4SPARKS KZhead Channel 👇
We Also Have A Dedicated KZhead Channel About Tools:
➤ / tools4sparks
⏱️Timestamps
00:00 - Intro
00:33 - A board with many problems
03:50 - Testing time
06:09 - Identifying the issue
07:39 - Lee’s Rant
10:36 - This amazing tool
13:30 - Insulation resistance testing
15:40 - Experts at work
PARTNERS/ARTISAN CODES
🔦Unilite Work Lights: Get 25% off all Unilite Products using our code "ARTISAN25"
UK Store - bit.ly/UNILITE
Europe Store - bit.ly/UNILITE-EU
USA Store - bit.ly/UNILITE-NA
Australia Store - bit.ly/UNILITE-AUS
💪🏼 Powered by Hilti Nuron - hilti.to/nuron_range
🕶 SafeStyle Protective Eyewear - bit.ly/3Svl4xG-SafeStyle Use code 'AELECTRICS10' for 10% off
💳American Express Business Gold Card
Sign up for an AE Business Gold Card using the following link to get a bulk of FREE membership rewards points - bit.ly/3JDmXVG
🥾 Big Boots - Save 5% on our amazing work boots when you use our discount code "ARTISAN" at checkout here bit.ly/BIGBOOTS
📚 Get 10% off when you use our discount code "Artisan" at checkout Here - bit.ly/3uY94dW-StudyStickers
🔋 Save 5% on EcoFlow Products using code 'AE5' - dada.link/58lAne
🎵 Use music the Artisan Way - Sign up to Epicmedic Sound here 👇🏼
www.epidemicsound.com/referra...
TRADES INSURANCE DISCOUNT
🦏 Use Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote 📞 or call 01162437904.
ENERGY PROVIDER
🐙 Get £50 credit when you switch to Octopus Energy 👇
➤ share.octopus.energy/zappy-sh...
📈Make the most of your KZhead analytics with TubeBuddy - Sign up here👇
➤www.tubebuddy.com/ARTISAN
AMAZON LINKS
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB?tag=ar...
📱 ARTISAN SOCIALS 📱
💬 Artisan Electrics Discord
➤ / discord
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
⏰ Artisan Electrics TikTok Account
➤ / artisanelectrics
💼 Artisan Electrics Linkedin
➤ / artisan-electrics
🎥 Get in touch with the Media Team
➤media@artisanelectrics.co.uk
This video is for entertainment purposes only please do not attempt to copy or recreate it. Do so at your own risk.
#sparkylife #electricianlife #artisanelectrics

Пікірлер
  • If you want to get our amazing tool of the day 😎(The TIS 570) then click the link to find a potential dealer for the product - 🧰🛠bit.ly/TIS570

    @artisanelectrics@artisanelectrics8 ай бұрын
    • lol "Potential dealer" you couldn't resist that one.

      @michaeljarcher@michaeljarcher8 ай бұрын
    • Just realised ...@@michaeljarcher

      @artisanelectrics@artisanelectrics8 ай бұрын
    • Nice bit of kit! But do not test PV Voltage with it as it only goes up to 300V DC AND the CAT IV Rating is only 300V For PV you need at least 1000V DC Range Probes also need to be rated for 1000V

      @animarkzero@animarkzero7 ай бұрын
    • That product looks like something for educational/home use but with a pro price tag. It only goes to 10A dc but looks like it should handle 200. Try the N2780 probe from Keysight - 500A AC/DC (but does need a scope..).

      @robertbox5399@robertbox53996 күн бұрын
  • You really think the customer deliberately went for a “budget” board? The house doesn’t suggest that. How about, he got fleeced by a contractor who charged him the Earth and went cheap with the electrics to maximise his profit.

    @BerkeleyTowers@BerkeleyTowers8 ай бұрын
    • Exactly

      @marcinkolanowski5167@marcinkolanowski51678 ай бұрын
    • This. Cowboy sparky based his price as he pulled up on the driveway for the first time.

      @Hustwick@Hustwick8 ай бұрын
    • He’s just getting click bate now ! Interesting title boring content !

      @garybillins4760@garybillins47608 ай бұрын
    • At the end of the day the house owner should have employed a qualified electrician to do the board change and electrics, not a builder or a kitchen fitter, which is obviously who has done this budget installation.

      @gadgetman36@gadgetman368 ай бұрын
    • @@HustwickHe wasn't a sparky, he was a builder or a kitchen fitter. That's why he's put so many circuits on a Type AC RCD in a split load board, he doesn't understand the finer points of electrics, or even the basics like earthing metal faceplates and light fittings. I'll wager that no testing was done beyond "the lighting and sockets are working" and the EIC is a complete fabrication.

      @gadgetman36@gadgetman368 ай бұрын
  • In the The Netherlands your only allowed 4 breakers per RCD, so in this case the customer should have had at lease 6 RCD’s.

    @peterhuismusic@peterhuismusic8 ай бұрын
    • We need that in our regs!

      @skreechy@skreechy8 ай бұрын
    • would that just encourage people to put too much on each breaker?

      @KX36@KX368 ай бұрын
    • @@skreechyIt's already in the regs that in most cases an RCBO board should be fitted, unless you have a good reason for installing a split load RCD board, which is very unlikely in a residential property.

      @gadgetman36@gadgetman368 ай бұрын
    • It’s 3 here in New Zealand. Often you’ll find a 45 way board in a 3 bedroom house 🤣

      @jackroberts691@jackroberts6918 ай бұрын
    • It’s 2 for Germany.

      @evenlouderthanthat@evenlouderthanthat8 ай бұрын
  • From the USA, I am amazed a the degree of thoroughness with which professionals perform an EICR in the UK. Nice catch that the RCD was occasionally tripping from the sum of the ten attached circuit leakage currents, none of which was, by itself, dangerous.

    @jeromewhelan6723@jeromewhelan67238 ай бұрын
    • Yea europeqns have standards😂❤

      @blacktee9292@blacktee92928 ай бұрын
    • Glad you see how professional we are haha

      @artisanelectrics@artisanelectrics8 ай бұрын
    • You should see the UK electrical regulations documentation. That said, I've seen a German electrical installation and it made even Artisan's pretty CU wiring look messy.

      @xmfclick@xmfclick8 ай бұрын
    • @@xmfclick thats what i honestly thought too 😉

      @blacktee9292@blacktee92927 ай бұрын
    • @@xmfclick UK regulations are crazy. They are ludicrously complicated yet they do not cover important points like the number of circuits per RCD. Enforcement is poor. My neighbours rented their flat to the local council who decided a new CU was needed. When it was sold the new tenant brought in an electrician who found brass switch plates on unearthed wooden boxes, and wall lights wired from the nearest wall sockets.

      @michaeltb1358@michaeltb13587 ай бұрын
  • I can see on your Megger that you have it set to Type A mode for RCD Testing - however the board contains a CPN RC263/030 - which is a Type AC RCD. Also amendment 2 of 18th edition states AC only testing should be used to test an RCD of any type, to determine if it is functioning and tripping within the required times. What I find quite funny is you even state later in the video how DC can blind an RCD and prevent it tripping - which is exactly what you did when testing a Type AC RCD with the tester set to Type A mode. Yes the board was cheap and a bit nasty, and a ridiculous number of circuits were run off each RCD....however the RCD itself probably does work for AC fault currents, just you were testing in the wrong mode.

    @blower1@blower18 ай бұрын
  • Really interesting to see how you test for this and then diagnose/fix the issues. Good video.

    @markharby180@markharby1807 ай бұрын
  • Absolutely loved this video, brilliant to see how methodical and precise you carry out your work. Brilliant the talk through measurements and procedures for a novice like me. Thank you

    @fattoamanowoodwork3638@fattoamanowoodwork36387 ай бұрын
  • why not just get some CPN RCBOs and move some circuits onto them. no need to replace the whole board

    @buggermecharlie@buggermecharlie8 ай бұрын
    • Discrimination & you can’t have two RCDs next to each other they don’t function properly.

      @lewischeal6646@lewischeal66468 ай бұрын
    • He said RCBOs!

      @krissybufton@krissybufton8 ай бұрын
  • Should have got one of your £30k rewires🤑

    @kevocos@kevocos8 ай бұрын
  • Had the same issue last year and trying to explain earth leakage to a client was hard work. But glad I changed the board for a RCBO and no issues 😊👍 Most appliances leak but it all adds up

    @bertiebassett1972@bertiebassett19728 ай бұрын
    • Trying to explain earth leakage to other sparks is hard enough 😂

      @MCKINJO@MCKINJO8 ай бұрын
    • It is never the easiest to explain to them but they do eventually understand

      @artisanelectrics@artisanelectrics8 ай бұрын
  • Great video guys, start to finish really well explained process 👍🏼

    @user-me9tx5hj7h@user-me9tx5hj7h6 ай бұрын
  • I hope customer was not paying for two guys spending all that time on an obvious problem. Just to recommend RCBOs. 30 mA RCD regs say max 30% leakage.

    @brianoneill350@brianoneill3507 ай бұрын
  • 3:58 looks like your testing a type AC RCD with the tester in type A mode - this is likely to be saturating the core of the RCD.

    @stunimbus1543@stunimbus15437 ай бұрын
    • Bro nice spotit 😂😂

      @user-yd2eb5ij7f@user-yd2eb5ij7f7 ай бұрын
  • To be honest, start of the video I was thinking they don't understand RCD trips but Luke's rant proved that he does understand it. Trying to find which circuit is at fault if there is a N-E low resistance can be hard work, usually drop the neutrals out and IR each circuit but using a clamp meter such as shown can really help. Using it around L+N at the incomer will only show up a reading proportional to any other circuit is actually drawing power though. You could just use the clamp meter around the individual CPC/earths at the board which is the same as clamping around L+N, then again that doesn't help if the earth leak is to a water pipe. Well done guys.

    @123mikeyd321@123mikeyd3218 ай бұрын
    • Both of these guys have gained so much knowledge about these things

      @artisanelectrics@artisanelectrics8 ай бұрын
    • Thought the same thing when they were switching off the breaker and measuring leakage getting half the story, I am pretty sure they were only single pole breakers.

      @grahamnicholson1553@grahamnicholson15538 ай бұрын
    • Clamping on the CPC doesn't show leakage to earth via other routes such as pipework etc.

      @farmersteve129@farmersteve1298 ай бұрын
    • ​@@farmersteve129And clamping all L+N together measures exactly what the RCD measures, just don't include E in the bundle .

      @johndododoe1411@johndododoe14117 ай бұрын
  • Should you do a ramp test on the suspect RCD?

    @frankgault7845@frankgault78458 ай бұрын
  • On Hagar boards you can replace an RCD with a special connector to allow you to replace the MCB's with RCBO's. Way cheaper than changing the entire board

    @curtisj2165@curtisj21657 ай бұрын
    • European boards (including UK) all use standard DIN rails, so any brand modules fit any board . Problem is that single pole breakers are usually 18mm wide each, RCBOs and other dual pole gear is usually 36mm wide each, and that board was packed almost completely, so they needed a larger board .

      @johndododoe1411@johndododoe14117 ай бұрын
    • @@johndododoe1411 RCBOs in the UK are almost always18mm, not 36mm wide. It's RCDs that are 36mm. Also, most UK RCBOs are single pole, although some makes have dual pole 18mm RCBOs.

      @TheEulerID@TheEulerID7 ай бұрын
  • We can see two RCDs, exactly as required by UK regulations, and yes, equipment used is Asian generic produce UKCA certified. Faulty RCD (and any other piece of equipment) needs replacement. In my opinion faulty RCD shall have beed replaced first and then observations made on leakage. Those observation could be improved, and Merel network analyzer unit used, or 24/7 monitoring installed (i.e. Supla), DC and AC leakage could be measured and then calculated per circuit separately. Worth to mention F type RCDs are not intended to protect from DC leakage over 6mA, and would help only when frequency is modified. That is a serious mistake. Only Type B RCDs would guarantee that DC leakage over 6mA would not block the RCD (and some RCDs type A+ used for EVSE that is still a rare product). Not sure if that job was worth 1000s...

    @klapouchy1000@klapouchy10003 ай бұрын
  • video was great helped out alot thanks as a newbie

    @oldirtyrod@oldirtyrod7 ай бұрын
  • If only all were as thorough as you guys. Excellent.

    @catabaticanabatic3800@catabaticanabatic38008 ай бұрын
  • Even if this is a fairly substantial installation I'm surprised there's so much combined earth leakage. Where I live (central Europe) it's still fairly common to have one whole-house RCD and I've never seen nuisance tripping like that. The one time I had utterly unpredictable RCD trips it was a faulty RCD. Old 100 mA RCD from the early 80s, tested the whole installation, IR wasn't great (some VIR circuits left in situ, came in at 8-9 MΩ) but nothing terrible. Replaced the RCD with a new 30 mA, hasn't tripped ever since.

    @Ragnar8504@Ragnar85047 ай бұрын
  • Absolutely agree get rid of split loads modern electronics have AC/DC leakage the cumulative effect has grown over time..Type B or F is the way to go but manufacturers as you say need to make them cheaper.

    @mathman0101@mathman01017 ай бұрын
    • Type B and F RCDs do not come as RCBOs, so would have to be installed as split loads.

      @spinlondon@spinlondon4 күн бұрын
  • Lee 14 mins in IR test you had CPC out of the board for testing as you mentioned, unless I am wrong should it be in place ref reg 643.3.1 (ii)

    @cranefamily@cranefamily8 ай бұрын
  • I learnt at college to test RCD's in isolation. IE, disconnect the outgoing neutral from the bus, and turn off all the MCBs. I've had issues testing an RCD from a circuit yet when testing it in isolation it passed.

    @simonabbott7323@simonabbott73236 ай бұрын
  • I’m impressed, very thorough fault find and test. There’s not too many sparks out there that are quite so conscientious. 👍🐙

    @wobby1516@wobby15167 ай бұрын
    • Cuz not too many sparks changing a £100 p/h lol

      @Tymoncik@Tymoncik4 ай бұрын
  • Great leakage test video. Ive only fitted 1 split load CU since 2022. Rcbo everything apart from garage 2 circuits. It is. Pointless to it RCD boards. Its a real hassle for the customer. Its hard to believe that was fitted as recently as 2020. Those kitchen sockets are pretty low on the counter. Just stick to 120cm height

    @aadd3538@aadd35387 ай бұрын
  • Well done great video when you are carrying out this type of work do you find it hard sometimes to explain the issue of earth leakage to your customers or builders , and do you sometimes feel they think you are looking for more work . Thank You.

    @garydrumm7263@garydrumm72638 ай бұрын
    • Tbf, we did get earth leakage clearly explained... by the oven repair guy. The oven NEFF oven was faulty. Still didn't solve the problem but, in checking the isolation switch to the oven, I found the spark had connected it up wrong

      @cuebj@cuebj5 ай бұрын
  • Toasters when not cleaned out can cause tripping.

    @Mr_Ashley@Mr_Ashley8 ай бұрын
  • This is why i only put rcbo's in nowadays. Problem now is that ive got loads & loads of mcb's lying around. Another note.... ive had a couple of issues where a neutral to earth fault would stop the rcd functioning correctly.

    @merlin5476@merlin54768 ай бұрын
    • Hopefully N-E faults should trip RCBs and RCBOs, because that's a massive leak right there !

      @johndododoe1411@johndododoe14117 ай бұрын
  • Well done. Loved this.

    @LoftechUK@LoftechUK7 ай бұрын
  • We have the rcbo version of that board and it is a delight. A led comes on when you open the cover too. It was being promoted by cef at the time. It certainly wasn't budget end. Very good video sharing the issues of earth leakage. Much appreciated

    @atkt62@atkt627 ай бұрын
    • I've fitted a few of the rcbo boards and never had issues.

      @marcusstonham@marcusstonham7 ай бұрын
    • It is a budget brand. Not great at all. Not as bad as Wylex or Fusebox but not great St all

      @peterigrenyi9176@peterigrenyi91767 ай бұрын
    • @@peterigrenyi9176 I'm surprised you say that. It has everything a homeowner looks for, and the automatic lights are really helpful. The rcbos and rccb have worked flawlessly since installation. And it was recommended by our electrician. If this is a budget brand then why do people need to pay more?

      @atkt62@atkt627 ай бұрын
    • @atkt62 just not built as well as more expensive brands. Also would expect a struggle with customer service if there is a problem. From my own experience with this board, terminals not great, screws on few mcbs/rcbos damaged when tightening withing torque limit, lid never sits quiet right, etc. I also expect more recalls on mcbs etc too. Just like wylex, craptree etc. Would much rather fit Hager. Cost probably not far apart.

      @peterigrenyi9176@peterigrenyi91767 ай бұрын
    • @@peterigrenyi9176 I understand your pov. However, we are 3 years into our cpn cudis rcbo board, not one issue. Our electrician says he fits these as standard. I guess everyone has their preferred brand. Look at the cars on the road as an analogy.

      @atkt62@atkt627 ай бұрын
  • Well thats a poorly designed system and sums up the lack of Knowledge of many sparks out there installing consumer units. Neither of them RCDs comply as the the leakage on both exceeds the max 9mA of leakage. As correctly diagnosed by Lee that board needs to come out. Good video and its good to see the Artisan guys doing it right. Shame our industry is in a state that work like that shown here has to be re-done. Well done Artisan 👌🏻

    @rattlehead85@rattlehead858 ай бұрын
    • Thank you for the kind words, we are glad you enjoyed the video

      @artisanelectrics@artisanelectrics8 ай бұрын
    • I thought it was 30% rating of the rcd, so 30ma would be 10mA?

      @MCKINJO@MCKINJO8 ай бұрын
    • @@MCKINJO Split hairs 9..10 fact is neither of them RCDs comply period. Whoever installed that board did not assess the installation neither did they show competence regarding compliance with regs.

      @rattlehead85@rattlehead858 ай бұрын
    • @@rattlehead85 always do an eicr before any work

      @MCKINJO@MCKINJO8 ай бұрын
    • It wasn't the sparky's lack of knowledge, it was the builder's or kitchen fitter's lack of knowledge in this case, because that's obviously who did all the shady electrical work and issued the dodgy EIC.

      @gadgetman36@gadgetman368 ай бұрын
  • Great content guys as always nice one 🇨🇮😎

    @marymadigan9707@marymadigan97078 ай бұрын
    • Thank you so much 😀

      @artisanelectrics@artisanelectrics8 ай бұрын
    • A viewer from the ivory coast?

      @roydowling2542@roydowling25428 ай бұрын
  • It just goes to show planning out things properly can avoid headaches in the future!

    @donaldduncan6017@donaldduncan60178 ай бұрын
    • Planning is essential

      @artisanelectrics@artisanelectrics8 ай бұрын
  • A failing or failed oven element doesn't always cause it to trip the electric I've had a few failed element that had not done that it usually happens when the l element is fractured and the 2 sides arc together nice video as always hope there is a part 2 were artisan waves the magic wand😅

    @ellisgarbutt1925@ellisgarbutt19258 ай бұрын
    • Just depends if the thermistor works properly

      @MCKINJO@MCKINJO8 ай бұрын
    • @@MCKINJO There isn't a thermistor.

      @mfx1@mfx18 ай бұрын
    • Some just fail open circuit, it is however more common that the fail with a pop and have a blowout which will trip the rcd and breaker. Then there are others that will trip the rcd as they warm up

      @johnwarwick4105@johnwarwick41058 ай бұрын
    • Our NEFF top oven had that - probably from manufacturing. Didn't solve the problem of the CU breaker tripping. Turned out the spark had connected the oven to an ordinary mains mcb, not the oven capacity one which was left unattached to anything

      @cuebj@cuebj5 ай бұрын
  • so many new builds are still having these double bank split load rcd boards installed in 5-6 bed houses, I've worked for companies putting them in. Never understand why they can't just add a bit more budget and get an rcbo board. Like Lee said they need to ditch split load boards all together but will they? There needs to be a dangerous situation occur for this to happen but most the time its just a nuisance

    @jonathanstephens7804@jonathanstephens78048 ай бұрын
  • What brand is that yellow spool? For continuity testing.

    @extraspace8475@extraspace84758 ай бұрын
  • We in the Netherlands mostly dont fabricate a board.We just buy it complete.And they do only 4 switches per RCD.

    @jooproos6559@jooproos65597 ай бұрын
  • Nothing wrong with the board as a piece of equipment, it meets all BS standards. It’s the design of the installation that is the problem. Swap out the RCD and MCBs for RCBOs for less than £150 and a couple of hours work.

    @steveb1856@steveb18567 ай бұрын
    • Ah yes but then you make no KZhead money, send two guys in to spend a day stating the obvious at 130 plus an hour and then recommend an entirely new board. God help the poor customer here. A couple of RCBOs as you say couple of hours work job done, but that does not pay for the overheads, the vans, the KZhead film guy etc. No wonder title says it costs you thousands

      @brianoneill350@brianoneill3507 ай бұрын
    • Very cheap RCBOs let us know where you get them

      @dritanboraku3259@dritanboraku32597 ай бұрын
    • @@dritanboraku3259 don't need to replace all. Just enough to bring leakage current down below 10 Mamps per RCD/RCBO

      @brianoneill350@brianoneill3507 ай бұрын
    • @@brianoneill350why so bitter Brian? 😅

      @KevinSmith-ph6jv@KevinSmith-ph6jv7 ай бұрын
    • @@KevinSmith-ph6jv I don’t like customers being treated like this.

      @brianoneill350@brianoneill3507 ай бұрын
  • aren't split load boards now non compliant 18th? unless you can prove the total ma is below a certain level

    @matthewmoody1978@matthewmoody19787 ай бұрын
  • Cudis CPN boards are completely fine. Prob more expensive than the Fusebox brand you guys fit. Retrofitting RCBOs into that DB would be totally fine

    @marcusstonham@marcusstonham7 ай бұрын
  • For my learning if you have downlighters in a room under a bathroom or wet room the downlighters should have an ip rating ? I think i understand downlighters in a bathroom should have an ip rating ?

    @yellownev@yellownev8 ай бұрын
  • Swap some circuits around between the two boards to spread the earth leakage between both RCD’s, job done.

    @TheRCBiker@TheRCBiker7 ай бұрын
  • Just put in an extra rcd on the string with the fault. Job done. I would imagine swapping the rcd for a new one would also fix it.

    @arquloc0893@arquloc08937 ай бұрын
  • I still have fuse wire in my CU like a cave man, ring mains and no earth lights, so this doesn't look too bad to me

    @georgehelyar@georgehelyar6 ай бұрын
  • There's no way that was a grand, look at the amount of circuits . Alarm bells start ringing here looking at the size and quality of the house . At first I thought the sparky may have recommended rcbo etc and the customer didn't want it but then looking at the quality of fittings and lights and then the consumer unit install shows different . I also suspect the RCD is rated at 63a not 80 so I bet at times that bottom one is overloaded also . As a temp fix, RCD change and move a circuit to the top bar such as the oven. However a new board or rcbo conversion is definitely what is needed .

    @danf6491@danf64917 ай бұрын
  • Changing all those MCB is to RCBO’s increases the limit of a collective fault current. Potentially you could have .33 of a Amp flooring to ground before the system would recognise it as a fault. Something worth bearing in mind.

    @demonkey123@demonkey1237 ай бұрын
    • What's wrong with that? A property with many devices can quite easily have 30-50mA of earth leakage on normal usage. Having it all funnelled through two RCDs means nuisance tripping. The 30mA trip is a safety limit to protect people. A human isn't going to have limbs long enough to touch all class I appliances in the house to sink that cumulative leakage current.

      @grahamek86@grahamek867 ай бұрын
    • I’ll tell you a story. I went to a house where the brother in law had done a board change. The property was TT with a single rod in the garden. The brother in law had got the tails crossed when he was doing it. The home owner hung a picture in the living room and hammered the nail through the neutral and earth. The system had approximately half an amp flowing to ground when I measured it. The tragedy was the owner had 2 beautiful Samoyed dogs. When I complimented her about the dogs she burst into tears. A third dog had died the previous week from a suspected hart attack. It’s kennel was less than a foot from the ground stake. I did not tell the owner what I suspected.

      @demonkey123@demonkey1237 ай бұрын
    • ​@@demonkey123unfortunately one can't completely legislate against fuckwittery. A ground stake, correctly inserted, will be at a depth where there shouldn't be step voltages between the stake and the transformer. That combined with the incompetent workmanship that caused crossed polarity. That said, the crossed "neutral" and earth by nail would have caused all class I appliances and any bonded plumbing to become live as a result. If RCBOs or RCDs were installed, they'd still trip.

      @grahamek86@grahamek867 ай бұрын
    • I agree, however my story was intended to highlight the dangers of an excessive unchecked current flowing to earth. An RCD protecting multiple circuits would only allow its maximum rated fault current to flow, while multiple RCBO’s allow a cumulative number of faults to add up to a significant amount of current flowing to earth unchecked. Using multiple RCBO’s doesn’t remove faults, it allows the system to operate under conditions that a conventional RCD protected system will not because it regards the situation as potentially dangerous.

      @demonkey123@demonkey1237 ай бұрын
    • ​@@demonkey123Assuming there are 10x RCBOs each allowing 29mA to leak to earth, that's 290mA leakage. What's fundamentally unsafe about that? It just means the house is full of leaky electronics. While it's undesirable, it's not inherently dangerous unless its traversing a human. Residual current devices are there to protect people. Circuit breakers are there to protect circuits. Providing the earth leakage doesn't exceed the circuit breaker and isn't flowing through a person, there's no real issue. A trip is only ever desirable if it is going to protect either a person, the circuit or both.

      @grahamek86@grahamek867 ай бұрын
  • Thats a lot of load on the bottom RCD. Over here in Malta, we used to have intermittent tripping due to inverters on A/C units and on the freezer. The solution was to use a type F RCD.

    @borgdylan@borgdylan3 ай бұрын
  • RCBO consumer units should by the norm once you go over 6 or 8 circuits

    @skreechy@skreechy8 ай бұрын
  • I'm a niceic dom inst and fit kitchens and bathrooms as a main business...found this video very helpful as keeps info fresh .. Good job Not sure about the hats though guys 🤔

    @seankybird7869@seankybird78697 ай бұрын
  • Ok, by the looks of the house the customer should be able to afford RCBOs, but if he couldn't, what would stop you from putting in another RCD or two?

    @xmfclick@xmfclick8 ай бұрын
    • An additional RCD needs two slots it seems and there are not enough slots available.

      @ChristianWagner888@ChristianWagner8887 ай бұрын
    • ​@@ChristianWagner888So just put some circuits on RCBOs and some on RCDs. Don't know what the regulations are regarding that over there but I have done some DIN rail control panels with RCDs and RCBOs in the US, and I will group together several circuits on an RCD if I want all of those circuits to trip if one of them has too much leakage (for example, for a PLC with inputs fed by different circuits or systems), but I will also install an RCBO if I want that circuit not to trip the common RCD (For example a large air compressor hooked to metal piping). Seems to me that this board could be fixed by reducing the number of circuits on each RCD, and putting in RCBOs for the circuits taken off. Done strategically this could be less of a hassle for circuits that commonly trip the RCD.

      @theodorgiosan2570@theodorgiosan25704 ай бұрын
  • Got the same tester from TIS. Soon unreliable I took it back today. U touch it reading changes, u look at it it changes.... Will certainly not use it again. Not found it accurate enough to help. Maybe faulty unit....

    @peterigrenyi9176@peterigrenyi91767 ай бұрын
  • Is it faulty RCD or Wrong RCd type chosen on tester🤔

    @edriselectrical@edriselectrical7 ай бұрын
  • As always, great work, guys, and brilliant content. I'd like to point out Luke has odd socks on 🤣

    @tonyBobb5209@tonyBobb52098 ай бұрын
    • Glad you enjoyed the video, we have said that to him before 😂

      @artisanelectrics@artisanelectrics8 ай бұрын
    • @artisanelectrics haha! I'd like to make contact with you or request a video on step by steps you need to take to become a qualified electrician. I am currently at this stage looking to take the step from being a complex telecommunications and fibre engineer working across the UK to become an electrician. Am I right in thinking I would need to complete a Level 3 NVQ Electrical Installation course, once completed (6 - 18 months depending how quickly you pass the models) to attend an 18th Addition course? Thanks in advance. Tony

      @tonyBobb5209@tonyBobb52098 ай бұрын
  • When you was doing the IR test and sensitive equipment was plugged in, what voltage was you throwing down? I always start at 250DC just in case

    @Kkelectrical541@Kkelectrical5417 ай бұрын
    • Edit. You prob test @ 250 now anyhow, forgot about reg 612.3.2 where value still remains at 1M ohm if doing so.

      @Kkelectrical541@Kkelectrical5417 ай бұрын
  • A simple switch to a type A RCD. No day long faffing around. IMO. Type AC is not suitable for residential, even less so for multiple circuits..

    @tamasstrezi3873@tamasstrezi38737 ай бұрын
  • These days, one should only accept a fully itemised quote with complete BOM that include copies of up to date trade certification, insurance etc and then further check them out as part of due diligence.

    @wajopek2679@wajopek26797 ай бұрын
  • Great video boys. Teaching and preaching the electrical safety message strongly, as usual......;)

    @LeighWinspear@LeighWinspear7 ай бұрын
  • So cool great video❤🎉😊

    @Maximess7@Maximess78 ай бұрын
    • Glad you enjoyed the video

      @artisanelectrics@artisanelectrics8 ай бұрын
  • Im a hobbiest electrician, i once helped somone fault find, only to find 22 plugs wired to a single 16amp rcd, with 4 spare. supposedly installed by a fully qualified electrician. Qualified or not does not mean the job will be done correct. Amazon was selling panels and all the the rcd were fake, just soldered connections inside. If its failed, break it open. Id love to become fully qualified but just dont have the money.

    @Twisted1409@Twisted14092 ай бұрын
  • At > 300ms can you tell me why this means the RCD has failed? I’m a spark in training!

    @liammoore5192@liammoore51927 ай бұрын
  • I'm glad I am still on ceramic wire fuses. Two blown fuses in 30 years and then that was because of old type light bulbs that are no longer in existence. This lot🙄one electrician to test and one to film.

    @shawng5799@shawng57998 ай бұрын
    • I'm suprised both of you don't use charriots to move around too! Ceramic rewirable fuses certainly works but they can't compete with how fast an RCD or RCBO trips in a fault condition and the safety such can provide. I saw cable insulation melt/get brittle because of continuous heat up circles without a fuse blowing up...

      @black.phoenix.@black.phoenix.8 ай бұрын
  • Hello lads i have never come across that make of board before you would have thought they would have installed an RCBO board in the first place rip it out and change it then all will be hunky dory it needed you lads on the job at the start love your high standards of work well done i say.

    @michaelscott3401@michaelscott34017 ай бұрын
  • do immersion heaters and ovens need to be on rcds over there?

    @Swe3ets@Swe3ets5 ай бұрын
  • Your quite rightly saying that CPN is a budget make and was adding to the issues and yet when you change boards you use Fuse Box which is also a budget range?

    @davidexley3110@davidexley31108 ай бұрын
    • But if its rcbos its budget and splitting the leakage to individual rcbos

      @MCKINJO@MCKINJO8 ай бұрын
    • Fuse Box may be a budget range, but I've found them to be fairly reliable in practise. More so than BG, for example, which is very common in the UK. I use either Hagar or Schneider for preference.

      @cobalt49@cobalt498 ай бұрын
    • The issue is that there are too many circuits on each RCD not that it was a budget make. The RCD's can easy be removed and RCBO's fitted rather than fit a new board@@MCKINJO

      @davidexley3110@davidexley31108 ай бұрын
    • I totally agree, buit this was a CPN board. 'I don't think the issue here is that make buit the method used.@@cobalt49

      @davidexley3110@davidexley31108 ай бұрын
    • @@davidexley3110 I know that. What I'm saying fusebox May be budget but it rectifies the problem

      @MCKINJO@MCKINJO8 ай бұрын
  • How I understand it you took the earth off the backbox and connected it to the switch. The regs state only a backbox with 1 fixed lug doesn’t need a earth to it, however here because of the isolator type lug you have now left this backbox without a earth, which reg does this comply with?

    @stephendawes8462@stephendawes84624 ай бұрын
  • So what was the item leaking ? The router?

    @max246@max2467 ай бұрын
  • Content of video very informative excellent explanations of faults found, BUT who was let loose in the editing stages and thought it good to drown out the dialogues with so called music? 😢

    @petesisson2987@petesisson29877 ай бұрын
  • I'd like to know how much that eicr cost?

    @simonr1392@simonr13927 ай бұрын
  • Is a split RCD board ever the answer these days compared to an RCBO board? Having worked on and installed both I find the RCBO board to be much easier all round, and I find it hard to believe that the overall cost will be much less with the split RCD board. With a decent quality but low cost RCBO board like the ones from Fusebox, what sort of difference in price are we looking at for say a 20 way board install compared to a similar quality split RCD board, both running type A RCD/RCBOs? It can't be more than 10 or maybe 20% surely?

    @craigchamberlain@craigchamberlain8 ай бұрын
    • It's cheaper, that's literally it

      @SBBUK@SBBUK8 ай бұрын
    • @@SBBUK Yeah I know... But in this case, surely if the spark had told the customer the reality of how many circuits will be lost just because one of them has a fault, then you'd think the (IMO) relatively small extra cost could be easily justified. Not to mention the cumulative leakage causing nuisance tripping. But that assumes the spark actually cared which seems unlikely, although it's unfair to speculate around the circumstances which led to this rather poor design choice. Obviously some people have no choice but to go for the absolute cheapest option, but that house didn't seem like somewhere you would install the cheapest option. Then again there are people who own fancy cars and install cheap tyres made of chinesium and wonder why they can't keep then on the road! I reckon kids should be taught about "value" as a core subject at school. Not just low vs high cost but actual value!

      @craigchamberlain@craigchamberlain8 ай бұрын
  • Heating elements in Ovens - cook-tops - Refrigerator defrost elements Electric Water Heaters - Oil-filled immersion heaters -- any appliance with a Heating Element is a primary suspect And having so many combined circuits that accumulate a high leakage current is walking a tight rope. The RCBO I use trip at 25Ma I would consider 30Ma too high and a safety hazard - Someone with a heart like a healthy bull may get away with it

    @andrew_koala2974@andrew_koala29747 ай бұрын
  • Great work guys 🙂☘️🇮🇪

    @davidryan6616@davidryan66168 ай бұрын
    • Thanks

      @artisanelectrics@artisanelectrics8 ай бұрын
  • I think a better understanding of intentional and unintentional earth leakage is required. Almost sounds like they are describing functional earthing.

    @spinlondon@spinlondon4 күн бұрын
  • What do we expect when testing a socket for polarity, when it proves to be correct on the left side socket but test the right side socket? Futile no? That board is an absolute mess.

    @CarlosArruda77@CarlosArruda778 ай бұрын
  • The Lumo led light function on that Cpn Cudis fuse box is not working because someone has removed the batteries lol.

    @danvictor3934@danvictor39347 ай бұрын
  • These RCDs are banned in Australia now. They were banned in 2018. They came back as "pulset" - which have a bad habit of failing internally. Also can't add more than 4 final sub-circuits to an old RCD here - because of this reason... Too much leakage.

    @tcpnetworks@tcpnetworks6 ай бұрын
  • type f rcd´s aren´t that expensive anymore well at least here in germany from siemens an type F is around 50€ and an type A at about 35€ and for just 15€ more i install an type f for the better safety, type b well thats another story they are still like 250€ and more

    @TheFlow2006@TheFlow20068 ай бұрын
    • Type A RCBO's here are around £20, type F is unavailable as an RCBO, only as an RCD and then is £100's. Type B are very hard to find as resellers here in the UK are complete morons and keep labelling Type A, B curve RCBO's as 'Type B' - so when you look for Type B rcbo's or RCD all you ever find is Type A, B curve.

      @blower1@blower17 ай бұрын
  • Should have gone for the £30,000 rewire! (around the median annual UK household income). I'm sure AE would have completed that in a week or less too. Material cost ~£800?

    @gareth4168@gareth41687 ай бұрын
  • I think you were trying to trip a type AC RCD but your tester was set to type A

    @starburst2203@starburst22037 ай бұрын
    • This is a big problem. Not enough education on the subject. A lot of devices with RCDs are returned to stockiest, just because of this problem.

      @alanwalton5735@alanwalton57357 ай бұрын
  • Swap the breakers for rcbos I think it's a nice looking board

    @NigelLewis-zs2lc@NigelLewis-zs2lc8 ай бұрын
  • I’m surprised you guys are so calm by the amount of circuits on one RCD. We can only have 3 circuits on a RCD in nz and Aus

    @robinengel4335@robinengel43357 ай бұрын
    • In many countries that initially went with separate RCBs, the original concept was one RCB for the whole house, then recently 2 to ensure some lights will still work in an emergency . Maximum breakers per RCB is a fairly new idea .

      @johndododoe1411@johndododoe14117 ай бұрын
  • Dodgy brothers board installs. As an aside I'm so glad the days of split boards and type AC RCBOs are over for new or upgraded installs in Australia.

    @ForTheBirbs@ForTheBirbs8 ай бұрын
    • Haha glad you are enjoying it in Australia!

      @artisanelectrics@artisanelectrics8 ай бұрын
    • @@artisanelectrics ask Jordan about Tim Tams

      @ForTheBirbs@ForTheBirbs8 ай бұрын
    • You want to see a rats nest you go to Australia and open fire resistant board that everything is just simply screwed onto front with all the wires sticking out the back

      @leexgx@leexgx6 ай бұрын
  • Why send 2 people to this job?

    @tombruton@tombruton7 ай бұрын
  • iinstead of upgrading the whole board is it possible to move some of the circuits to a sub board? #questionfromalayman

    @brettuk@brettuk8 ай бұрын
    • bump

      @brettuk@brettuk7 ай бұрын
  • Clutching at straws when you diagnose the issue on the half of the installation that has more earth leakage that has the majority of the load. Also when you’re only issue with the cert is the cut out that the clearly shouldn’t have looked at anyway

    @joemoore9991@joemoore99918 ай бұрын
    • I always put a limitation on the test sheets when it asks for the main fuse size as how do I know what size it is just because it says 100A or 80A means nothing as someone could have put a different size fuse in the carrier and we should not be able to remove that fuse as it should have a seal

      @markpotter8280@markpotter82808 ай бұрын
  • I’m an apprentice, could you not have put in another RCD on each row to half the loads on each rcd instead of suggesting full rcbos

    @harveynicholson4620@harveynicholson46204 ай бұрын
  • Spotted USB sockets in the kitchen. That will be accounting for some if not all of the leakage and if they've got a few more dotted around, easily make up the 20ma leakage on one side of that CU.

    @SolisNotSolis@SolisNotSolis7 ай бұрын
    • Well spotted!

      @artisanelectrics@artisanelectrics7 ай бұрын
  • In a new build house from FH 2020... MCB on 2 RCD devices. I would have PAID for the upgrade to AFDD + SPD. Also pulled 6mm to the detached garage. Again, would have paid for an upgrade to the cable to make adding a car charger easier.

    @webzterd@webzterd8 ай бұрын
    • Most new builds are designed by the client, and are designed 1-2 years prior the the current regulations. It’s not always the electrical contractor at fault, their job is to do as the spec says. As always we can advise they do things different but if you have 40+ houses like some sites I work on an extra few hundred quid per house stacks up quickly, so they tend to avoid. Speaking from experience on this, it’s an impossible task to speak sense into the senseless 😂

      @chrisdobbo8938@chrisdobbo89388 ай бұрын
  • Excellent video

    @g.williamswilliams8442@g.williamswilliams84425 ай бұрын
  • Can anyone help as I have had earth leakage over 30ma and the RCD don't trip 🤷‍♂️

    @thorntonselectrical968@thorntonselectrical9687 ай бұрын
  • In the netherlands it`s not allowed to have more then 4 end groups behind an rcbo.

    @irqanonimous3278@irqanonimous32784 күн бұрын
  • 60A seems too low for that house. Is that what is really in it?

    @wisteela@wisteela7 ай бұрын
  • noone can afford rcbos in my country so much that you can hardly buy them in shops. 1 RCD is standard, thats it. Envy you guys in the uk.

    @TPV07@TPV078 ай бұрын
  • Watching these professional electricians videos on KZhead makes me feel sick to my stomach because of what I did in my old parents house when I was little and when we moved out I did not tell anyone about the horrible botchery I hid in the walls secretly.. when I was 14 years old I had only one ceiling light in my room so I wanted to add at least one more so I used the earth wire going to the ceiling fixture as another phase wire and I did the same thing going to the single switch and I never told anyone about it, the same goes when I wanted to add another few sockets in my room with different breaker so I used the existing earth wire in my room as a second phase wire and nobody knows that. When we moved out I never told anyone about it. I was scared my mom would kill me for that lol.

    @mr.dahliaking.202@mr.dahliaking.20214 күн бұрын
  • “So basically you’d have an RCD on each one basically, which would allow you that allowance” hahahaha

    @jayc1140@jayc11407 ай бұрын
  • OK...yeah.. it should have been a RCBO board in the first place, but it isn't. Why is the go-to solution to replace the board, when the problem could be resolved by simply adding another RCD and splitting the bottom row?

    @usscork@usscork7 ай бұрын
    • Bus bar cut for the RCD's and you can't buy just the bus bar for an upgrade would be my guess.

      @jonathanbuzzard1376@jonathanbuzzard13767 ай бұрын
    • @@jonathanbuzzard1376 Hey 👋, I'm not sure if you are referring to the mounting rail, the MCBs etc clip onto, or the Bus (aka Buzz) Bar that connects the Line from the RCD to the MCBs? Presumably it's the latter, but correct me if wrong. The Bus bar is very cheap, readily available and easy to cut etc. There would be no problem cutting the existing bar to split it; put in a new RCD and a new Bus bar, splitting the MCBs between the two; and take a separate feed from the Main switch and Neutral bar to the new RCD. Oh.... perhaps you mean another Neutral bar??? Ahh yes, that might be a problem alright. 😅

      @usscork@usscork7 ай бұрын
  • 15mA on one and 20mA on the other. The maximum permitted leakage on a single RCD is 30% of the rated residual current which is 9mA. Further investigation is definitely required to establish where the high leakage is coming from on both RCD’s. The board looks cheap and poorly installed.

    @alvina69@alvina697 ай бұрын
  • What's the problem with cheaper brand? Not all electricians charge as much as you do.

    @przemyslawjuskowiak6750@przemyslawjuskowiak67507 ай бұрын
  • I'm so confused I'm not a spark but why do they want more earth leakage before it trips? Isn't that a bad thing? 2:40

    @johnnybartlett1431@johnnybartlett143117 күн бұрын
  • Why is there deliberate leakage in all appliances?

    @jameswyatt1304@jameswyatt13048 ай бұрын
    • Not all, but lots of modern electronics leak through filter caps on power supplies. Normal operation, and not a problem normally, but load lots on one rcb and this happens.

      @BerkeleyTowers@BerkeleyTowers8 ай бұрын
    • Switch mode power supplies that reference ground and EMC filters are the most common ones. It’s not strictly “intentional” but rather unavoidable would be a better term.

      @Pugjamin@Pugjamin8 ай бұрын
    • For EMC compliance class X and class Y capacitors are fitted between L, N & E. Each device (PC PSU, audio equipment etc) may add a few mA to earth leakage. I was involved in the design of a large non-domestic LED display where we fitted 32 off small DC power supplies. Each had it own EMC capacitors, and a soon we tried to power it up, the 30mA RCD on the supply tripped. We had to remove the internal EMC filters and fit 1 external EMC filter to each set of 4 PSUs. At home I had a cheap Tesco DVD player. It had a two wire mains connection (no earth), X capacitors to its metal case, and a switch in the neutral. When it was "turned off" one could get a slight shock due to the L-E capacitor. I notified the supplier of this design fault, but had no acknowledgement.

      @BrainW33a@BrainW33a8 ай бұрын
    • @@BrainW33a Many an old Sky box has zapped me over the years, thanks to it's EMC filter caps putting halfwave rectified mains AC out on various connections.

      @blower1@blower18 ай бұрын
  • Van battery's a bit low. Should be 12.8V once the surface charge is dissipated (doesn't take much load to do that - interior light or just the key on ACC will do it pretty quickly). You'll want to get that load tested before the first cold snap.

    @TonyRule@TonyRule8 ай бұрын