DO YOU NEED TO EARTH BOND PLASTIC WATER PIPES?

2024 ж. 1 Мам.
119 903 Рет қаралды

Wiring regulations change but some electricians' still struggle when it comes to connecting earth bonding to pipes, especially when the incoming water pipe is made from plastic.
Joe Robinson explores the topic of earth bonding and plastic pipes.
======================
🕐 TIME STAMPS 🕕
======================
00:00 Do I need to bond plastic pipes
00:15 The Knipex Bix pipe cutter
00:47 What does BS7671 say
01:30 From the supply transformer
01:57 TN-C-S supply
02:37 Metal pipework with earth potential
03:53 Adding a protective bonding conductor
04:20 Incoming plastic pipe
================================
🔦 More electrical Q&A videos from eFIXX
👉 www.efixx.co.uk/electricians-...
================================
🆕 FREE CPD Learn about new applications, regulations and best practices with our FREE CPD modules. - New modules are released every month, covering everything from surge protection to lighting.
👉hub.efixx.co.uk/CPD​
================================
📍SUBSCRIBE TO THE CHANNEL
eFIXX helps electricians, electrical contractors, building services engineers, and electrical apprentices. So if you've been on the tools for years or just starting your electrical journey, we'll help you stay up to date with the latest regulations and developments in the electrical industry.
👉hub.efixx.co.uk/youtube-subscribe
========================================
📺 NEW TO THE CHANNEL?
Watch our essential videos playlist
👉 hub.efixx.co.uk/essentials
=========================================
#efixx #electriciansQ&A #earthing

Пікірлер
  • More electricians Q&A here 📺👉kzhead.info/channel/PLmWOIPxaBWH7XMcW07S7CTQM9G-M1GHzc.html

    @efixx@efixx2 жыл бұрын
    • late to the party, but you can't bond plastic. it's simply common sense, so you might want to do a 2 hour video on what common sense is :-D (bad danish joke)

      @boherrmannsen8219@boherrmannsen82192 жыл бұрын
  • As an apprentice, this helped me alot. More on this topic please eFIXX!!!

    @bigshoe9130@bigshoe91302 жыл бұрын
  • "You can't apply bonding to protect from faulty installation elsewhere." I wholeheartedly disagree. Workmanship is always a variable when making standards, and overlapping protections save us every day.

    @tomcapon4447@tomcapon44472 жыл бұрын
    • Not in this case

      @lhffan@lhffan2 жыл бұрын
    • @@lhffan But, you asked what we would do. We know that there are idiots who do unsafe work. We also know that we are all human and minds do wander. On the other hand, if the fault was in the consumer unit, bonding it could make things much worse.

      @dalekify@dalekify2 жыл бұрын
  • 18th edition says no to bonding plastic incoming pipes. btw - It’s either earthing or bonding, not earth bonding. They’re two separate functions 👍🏻

    @CarlCosby@CarlCosby2 жыл бұрын
    • What it should say is that in that case then any metal sink or fitting should be earth bonded to a ground spike

      @gowdsake7103@gowdsake71032 жыл бұрын
    • It’s either earthing or bonding, they’re two separate functions. The sink isn’t an exposed conductive part, therefore not required to be earthed. The sink “could” be an extraneous conductive part, if so, it would therefore require protective bonding. If not, no protective bonding. There’s a test one can do to prove if something is or isn’t considered extraneous.

      @CarlCosby@CarlCosby2 жыл бұрын
    • @@CarlCosby What is that test?

      @tristandowning5609@tristandowning56092 ай бұрын
  • I live in Germany. We have TNC-S and a plastic water pipe. The pipes in the house are made of copper and are bonded to the foundation earth. The house is almost 50 years old. As far as I know, the heating engineer has requested that the earthing is available, so the earthing is not at the inlet of the pipe but on the heating system. But that doesn't matter with copper tubes.

    @jensschroder8214@jensschroder82142 жыл бұрын
  • Your tutorials are excellent.

    @christopliss9947@christopliss99472 жыл бұрын
  • We do the main bonding usually in the hot press in Ireland, under the sink would be supplementary bonding to the sink, but in the new regs due to lack of bonding points, ie no flange on sinks plastic pipes and flexible braided pipes. if we prove there's no earth path we don't have to bond, ie via insulation test .

    @patrickoregan2148@patrickoregan21482 жыл бұрын
  • There is the electrostatic potential, and the flow of water can still give a little charge. I have seen dust cling to plastic water pipes in use, although current is minimal the field is quite large.

    @davidhilton7780@davidhilton77802 жыл бұрын
  • The plastic pipe obviously doesn't make a direct connection to earth, but what about any metal pipe fittings further down the road? At mains voltage water can act as a conductor (or we wouldn't worry about IP rating for things exposed to damp environments) so while the path to earth via the pipe itself doesn't connect to earth directly under the house, surely there's a path to earth via the water in the pipe itself? I accept that the potential is probably a lot lower than the actual copper earth that comes into the building though, so likely wont be a problem, but I would still expect that there is the possibility of an issue there.

    @AdrianBawn@AdrianBawn2 жыл бұрын
    • Exactly except bonding to the pipe would be utterly pointless but anything metal should be bonded on the water system

      @gowdsake7103@gowdsake71032 жыл бұрын
    • Demo of how little current would actually flow through the water in the pipe: kzhead.info/sun/gKpydKeGopN7a4E/bejne.html

      @simongreenidge6454@simongreenidge64542 жыл бұрын
    • ​@@simongreenidge6454 Where I do think there could be a concern is when the insulating section is very short. If there are meters of insulating pipe then the current is going to be reduced to non-hazardous levels, but if there are only a few centimeters of insulating pipe between sections of conductive pipe that could be a different matter.

      @petermichaelgreen@petermichaelgreen2 жыл бұрын
    • If water pipe enters to the dwelling in plastic you don’t need the bonding . That is all

      @Electric-First@Electric-First2 жыл бұрын
    • @@petermichaelgreen Yes, an interesting situation. This video also makes me wonder whether, in a house with a plastic incoming water supply pipe; does any of the network of copper water pipe within the house be (supplementally) bonded e.g. the bathroom?

      @simongreenidge6454@simongreenidge64542 жыл бұрын
  • I had a thing about 15 years ago . Plastic incoming main . All the pipe work in the flat was plastic. Customer had a electric shower and complained he got a nasty shock . Shower was about 8 foot away from the incoming plastic main. Couldn’t find anything wrong on testing. It was also a intermittent thing..After a lot of head scratching it was Infact a fault on an adjacent flats water heater .The element was faulty, so was the voltage operated trip. The fault was Infact traveling through the water in the plastic pipe into my customers flat and earthing through him when he was stood in the bath using the shower.. most tradesmen round here still use copper but if it’s plastic I get them to put a small copper section in so I can earth this so this sort of thing never happens again . This was a potentially dangerous situation that no one seems to consider

    @andysims4906@andysims49062 жыл бұрын
    • In this case, was the shower unit itself, and therefore it's constituent metallic parts, not earthed?

      @jemmyh2511@jemmyh2511 Жыл бұрын
    • Similar thing happened to me .. but the author of this page stated in a comment above that tap water is not the conductive .... he’s lost me there .

      @leetaylor5988@leetaylor5988 Жыл бұрын
  • I've seen a voltage difference between cold and hot pipes within a house form when the hot water pipe heats up as a tap opens. I'm just wondering if in future a reg will come out with a bonding portion of pipe to bring the water to a zero potential.

    @marksmith6259@marksmith62592 жыл бұрын
  • Does this still apply when these water pipes are surface mounted on walls throughout an installation and include outside taps and electric water heaters? As exposed conductive parts, there is no question that they shouldn't become live, but what does the term 'under fault conditions' apply to? (Have bonded pipes in an installation like this recently)

    @jimmylovescake6813@jimmylovescake68132 жыл бұрын
  • To the “I’d bond it anyway” brigade the video clearly shows that when it’s not extraneous it’s no different to any other metalwork in the property. If you “bond it anyway” you’re going to introduce a fault current that wouldn’t otherwise exist. We’re all about keeping fault currents away from people yet bonding an irrelevant piece of metal is increasing the chances of someone coming into contact with live metalwork. Or am I missing something?

    @squakkers@squakkers2 жыл бұрын
    • Exactly 💯 buddy. Its potentially putting someone at risk of electric shock in the event of the pipework becoming live because there would not be a return path.

      @coralbay00@coralbay002 жыл бұрын
    • @@coralbay00 so shouldn’t bonded conductive parts that are not extraneous be coded C2 or FI on an EICR?

      @squakkers@squakkers2 жыл бұрын
    • @@squakkers probably hard to prove its not once the plumbing is fully assembled mate. Have to trust the original designer... But given some of the comments on here that's probably easier said than done.

      @travoltasbiplane1551@travoltasbiplane15512 жыл бұрын
    • @@squakkers it's a dark area that one. Tbh I would consult niceic (since I'm paying for 2nd opinions) and get advice if I couldn't clarify. The internal pipework throughout the building can in itself be unpredictable. Ie bathroom fitters rock in and cut into the copper slapping in plastic pipe potentially breaking continuity. Put on the spot.......I would agree C2 if certain and fi.......if uncertain. Don't you just love earthing arrangements 🤦‍♂️

      @coralbay00@coralbay002 жыл бұрын
    • @@coralbay00 No! 🤣

      @squakkers@squakkers2 жыл бұрын
  • On a brand new install i would accept the non-bonding of plastic incoming water pipes ( what about plastic gas pipes then ? ) Existing installs can and do bring the risks of cables being found under floors etc resting on metal heating pipes etc ( but they could now be all plastic !) The discussion on protecting metal sinks on older BS7671 regs brought similar conflicting views didnt it ? Personally, I'd still bond and do continuity tests to verify integrity.

    @MultiOutdoorman@MultiOutdoorman2 жыл бұрын
  • To muddy the waters, PME/TN-C-S installations are required to have an insulation joint the gas supply if it's via a metal pipe to stop it carrying any fault current. So does the gas pipework downstream of the IJ still need to be bonded? And what about the exposed metal pipework upstream of the IJ as that can't be bonded. FWIW the incoming water main is black MDPE so shouldn't need to be bonded but I ran a new 10mm² cable to avoid an argument with the commissioning electrician when I changed the CU.

    @Graham_Langley@Graham_Langley2 жыл бұрын
  • Like someone else has said I wondered about the water conducting. I am not an electrician, but have this question which many DIYers must have come across. Metal pipe into the house and to the sink with bonding at the taps. Kitchen redone with all plastic plumbing from the point the water comes into the kitchen. Stainless steel sink fitted with metal taps, but plastic tails and plastic as far as the kitchen door. I assumed that because the sink is insulated now there was no point in any sort of bonding. In fact even when there was bonding I was never sure of the logic on a metal sink. I sort of thought I understood on a plastic or pot one that connecting the hot pipe to the cold gave a route back to earth so that seemed sensible.

    @seankearney6915@seankearney69152 жыл бұрын
  • I knew it!!! I thought it did not make sense when my electrician said my incoming water mains must be bonded even though it comes through MDPE pipe. Glad this video sorts it out!

    @Tomukas@Tomukas2 жыл бұрын
    • In one job the guy came to change the gas meter, saying where is the earth cable to the water stop cock. We told him it is not needed as it was plastic. He left not doing the job. As he was leaving we called him an incompetent lazy ****. We kicked up about it and in also stated it was not needed quoting the reg. And not to send back this incompetent idiot. They apologised sending a different guy.

      @johnburns4017@johnburns40172 жыл бұрын
    • @@johnburns4017 You sound delightful

      @James_scott86@James_scott862 жыл бұрын
    • It’s recommended to still bond if the rest of the installation is all metalwork. What he said in the video about cables being spaced away from pipes is just wishful thinking. Look under your floor boards, cables wrapped around pipes is basically guaranteed, check your boiler, immersion heater, appliance cables behind sinks etc. You’d be deluded if you think everything’s a1 just because you can’t see it.

      @Chris-gt3rs@Chris-gt3rs2 жыл бұрын
    • @@James_scott86 I do not tolerate idiots.

      @johnburns4017@johnburns40172 жыл бұрын
    • @@Chris-gt3rs With RCDs and RCBOs the need to bond a pipe not connected to earth disappears. No need. As was stated you do not design a system expecting it to be a cowboy job.

      @johnburns4017@johnburns40172 жыл бұрын
  • Good explanation, makes sense.

    @metallitech@metallitech Жыл бұрын
  • Interesting video, but I suspect the more complex answer is "it depends". You're only considering the water supply as it enters the building. What if some of the copper is in contact with the earth elsewhere, e.g. a kitchen island? If you can guarantee that it's not, that there is probably more danger of metallic parts becoming live under fault conditions if they were bonded. However, it's also very likely that a boiler (for example) will have all the metallic pipework bonded, so the point is probably moot anyway. If in doubt measure it, and make a decision based on that.

    @matthewmelbourne9139@matthewmelbourne91392 жыл бұрын
    • This literally came up on r/electricians this week. Pipes not bonded at entry, shorted to hot through a stray wire, and now all the fixtures in the house have live voltage on them relative to anything plugged into an electrical outlet.

      @tomcapon4447@tomcapon44472 жыл бұрын
    • @@tomcapon4447 Which is why we have everything behind a GFCI in the Netherlands and not only bathrooms or only sockets.

      @FoodOnCrack@FoodOnCrack2 жыл бұрын
    • @@FoodOnCrack That’s how it is in the U.K. too.

      @Orgakoyd@Orgakoyd9 ай бұрын
    • would the dpm in the floor act as an insulator to avoid contact with earth, plus you would use plastic pipes to an island to avoid the corrosion of copper , simple answer cross bond gas water and heating pipes

      @EdwardBretherton@EdwardBretherton3 ай бұрын
  • In a house with radiators that are plumbed with copper pipe; are the central heating water pipes bonded completely independently of the house water supply? Could disconnecting the water pipe bonding mess with the radiator bonding?

    @simongreenidge6454@simongreenidge64542 жыл бұрын
  • My house has bonding in the bathroom, kitchen and down stairs loo. But the pipe bringing in the mains eater to the d s loo is plastic. All water supply pipes in the house are copper except the ufh on the ground floor. So if all copper pipes have bonding but I do not believe is bonded back to ground? So what is the point, think the house was built in the 70"s Should I bond the nearest pipe to the supply metal protective shield, which is under the stairs and the ufh manifold 22mm copper pipes are there to approx 1 meter away. Thanks for the thoughts on earth bonding and video.

    @anthonytidey2005@anthonytidey20052 жыл бұрын
  • So out of interest on the EIC do you put N/A in the tick box then? Would this be sufficient or would you need to prove bonding is not necessary by providing a measured resistance value to prove it isn’t required ?

    @mick8821@mick88212 жыл бұрын
  • Interesting, I have a blue feed pipe and have earthed internal pipping but was told to also earth stake the internal side of the stopcock with 16mm. This video got me thinking, I had wanted to run a soft copper insulated radiator supply a short distance to the garage in the ground, & the boiler is external oil but the oil supply pipe does already run in the ground !!! This is going to be sleeved in the future but never the less getting wet. & what about old house pipes that in concrete floors. The supply in is overhead line & earth with a main RCD.

    @davekendall9749@davekendall97492 жыл бұрын
  • In The Netherlands every home has there own earth-rod connection to the earth. The water inside the pipe may be conductive as well. Therefore inside a bathroom a metal schowerdrain, a metal radiator, warter-taps etc etc are bonded to an earth-wire as well. In older houses with wooden floors, where there is a steel floor-support (in concrete on top of the wooden floor), the steel is earth-wired as well. Is that different form the UK?

    @stamplusalmelo@stamplusalmelo2 жыл бұрын
    • Yes, most connections in the uk, except for a few rural properties have either a separate earth connection from the local distribution, or an earth connection which is tapped off the neutral as it enters the property (and the neutral is regularly earthed along its path from the transformer to the property). Bonding varies depending on the age of the property and what wiring regs were being worked to. Building metalwork is also bonded, but steelwork is not very common in uk homes (it’s only usually in one off type builds or commercial buildings). It’s amazing to see how differently different countries approach the same problems.

      @MorzakEV@MorzakEV Жыл бұрын
  • Good day this is Mike from Amsterdam Holland we got the same problem here but the regulations are you have to bond your tube because when it conduisait it will still conduct the bonding

    @reusinkinstallatietechniek6256@reusinkinstallatietechniek62562 жыл бұрын
  • tnx for video! very useful...

    @user-gx4bm4zn6o@user-gx4bm4zn6o2 жыл бұрын
  • Bond it so you don't have an argument when ev installer comes round and does a quick check. 🤣

    @bencampbell2041@bencampbell20412 жыл бұрын
    • My ev charger was installed today, but it won't be remotely activated until i get the bonding done 😒

      @kroon275@kroon2752 жыл бұрын
    • 😂so true half a idea is dangerous

      @duncanovens158@duncanovens1582 жыл бұрын
  • This is to assume that the only connection point between the ground and the water pipe is the incoming pipe. An underground feed in conductive piping to a garden tap or outbuilding would do the same thing. There may be other possibilities too, whereby the property's internal conductive pipework has a connection to the ground. It may be rare, but it surprises me that it is not mentioned in the regs as a possibility. Of course, the most likely way that the copper piping would have a connection to the ground would be via a gas boiler if the incoming gas supply is via conductive pipe, but then the bonding on that ought to deal with the situation.

    @TheEulerID@TheEulerID13 күн бұрын
  • Since the city water is conductive enough to prevent static charge from building up with a non-conductive pipe it's not necessary, but if the pipe were transferring a non-conductive fluid such as oil or gas, absolutely ground both ends of it as the friction between the non-conductive pipe and the flowing non-conductive fluid builds up a static charge.

    @TurboBaldur@TurboBaldur2 жыл бұрын
    • Any working fluid through a closed isolated loop will exhibit some potential...

      @davidhilton7780@davidhilton77802 жыл бұрын
    • @@davidhilton7780 yes absolutely, but any conductivity in the fluid will drain the charge away, but of course with enough friction and not enough conductivity you can get a charge building faster than it dissipates.

      @TurboBaldur@TurboBaldur2 жыл бұрын
    • @@TurboBaldur so wouldn't bonding both ends of a non-conducting line to conductive ends safely dissipate the static in the line and reduce the risks...

      @davidhilton7780@davidhilton77802 жыл бұрын
    • Thanks for your input, I enjoy it greatly. And thank you for conversation on something as trivial as bonding.

      @davidhilton7780@davidhilton77802 жыл бұрын
  • What if there is a bond wire to the cold water pipe inside the apartment. At some point, the plumber replaced the feeder pipe with PEX. Is there an easy way to check whether that was the main earth ground of the apartment, and would it need to be rebonded or to add earthing rods?

    @mrtechie6810@mrtechie6810 Жыл бұрын
  • Joe you cannot state that if the service pipework is plastic then it does not require main equipotential bonding. It is possible that elsewhere within the property that the installation copper pipework enters the true earth and comes back up again, and therefore can be deemed extraneous. A simple test to prove is what I do,....continuity test between the MET and the pipework. If the reading is

    @asp217@asp2172 жыл бұрын
    • Regulation 411.3.1.2 states it. If the metal pipe enters the ground as you've described then it's a different situation and may well need a bond, if it changes to plastic where it enters and exits the ground it won't. I know what you're saying though Andrew and there'll be much more information on this subject on the way. 😊

      @efixx@efixx2 жыл бұрын
    • Even if it doesn't enter earth and rise again the point of bonding is nothing to do with that.

      @stuartcraigon2003@stuartcraigon20032 жыл бұрын
    • @@asp217 sure I fixed it for you seeing as you can't read!

      @stuartcraigon2003@stuartcraigon20032 жыл бұрын
  • My boilers gas pipe will bond the water pipes but this may give a potential difference as it's not as direct as bonding the water pipes directly. This applies to indirect earth connections via an immersion heater, the motorised valves, a waste disposal etc etc. The pipes to radiators or an outside tap may also be contacting the ground at various points so I think pipes should be bonded regardless to assure continuity of earth protection, seems daft not to.

    @wrdcc01@wrdcc012 жыл бұрын
    • The gas pipe might be bonded but why does putting supplementary bonding on water at point of entry help? If you need supplementary bonding - which given exemption for RCD protected circuits you can't imagine how you ever would in a modern domestic installation - then you'd install the supplementary bonding in the bathroom not at the stopcock.

      @keirstitt8277@keirstitt8277 Жыл бұрын
  • Once the metal pipework enters a class 1 appliance, like a water heater or central heating boiler, it will likely get bonded anyway via the chassis being earthed.

    @davepusey@davepusey2 жыл бұрын
    • what about when the ground cable of the appliance /socket get disconected

      @TheMakyato@TheMakyato Жыл бұрын
    • @@TheMakyato How would this happen?

      @Orgakoyd@Orgakoyd9 ай бұрын
    • @@Orgakoyd by human error or accident , in europe can happen especially with boilers or washing machine . sometimes you can get electrcuted just on the wet floor

      @TheMakyato@TheMakyato9 ай бұрын
  • I've always been puzzled about bonding, the reason being, every piece of metal pipework is connected to a CPC, maybe not, but I can't think of the scenario when that's not the case. If you have a gas supply and boiler, the CPC for the boiler connects any metal pipework to earth as would any water heater. A gas boiler connects the CPC to both the water and gas, though I do seem to remember that some boiler manufactures don't do this, I'm not certain of that. When the water companies changed the network to plastic a lot of older properties lost their earthing system all together, as it used to be common practice to use the water pipe as very reliable earth. There are thousands of properties, especially older ones that no longer have a proper earthing system. Why aren't there dead people everywhere due to this issue?? Totally agree that there's no point bonding metallic pipework if the incoming pipes are plastic. Great video and thank you.

    @J0nny61@J0nny612 жыл бұрын
    • All very good points, any metal work that does need bonding will need a bigger cable than most CPCs provide though. Stay tuned for more!

      @efixx@efixx2 жыл бұрын
    • @@efixx Thank you for replying, when you say most CPC's will need a bigger cable it would depend how the earth fault was initiated. The adiabatic equation proves that most CPC's can withstand a far higher fault current than the protective device will let through. Food for thought.

      @J0nny61@J0nny612 жыл бұрын
    • The need for good grounding is to trip the breaker at a fault. The safety of the house comes from having one single potential on all toucheble surfaces. If all metal pipes, electrical enclosures and house frames are bonded you will not get electicuted even at a fault. No need for good earthing 😀.

      @scoutjonas@scoutjonas2 жыл бұрын
    • @@J0nny61 we are not concerned with an internal earth fault when we talk about main bonding. We are concerned about bringing all extraneous metalwork to the same potential as the installation earth. The bonding conductor will be sized to cater for diverted neutral currents

      @tomorichard@tomorichard2 жыл бұрын
    • It's correct name is equipotential bonding. Why? Because all points are at the same potential. Let's not get confused between earthing which CPC's are for, and bonding. They fulfil two different requirements.

      @deang5622@deang5622 Жыл бұрын
  • My home in the US has plastic PEX piping and it is not bonded to the electrical service ground. Code does not require it. However, water is a conductor and water flows from buried metal pipe in the street and comes in contact with metal valves and fixtures in the home. Could a voltage potential be applied somewhere in the system, perhaps a faulty electric water heater element? Perhaps bonding at a location near the entrance via a stainless steel or brass pipe fitting might be a good idea?

    @rhyoliteaquacade@rhyoliteaquacade2 жыл бұрын
  • "We can't bond just to cover poor installation" This is a correct statement... However. I was receiving shocks and tingles from my New washing machine and kitchen sink, turns out Mice had chewed through the Flex feeding the washer. This left the live conductor touching the water feed pipe and therefore livened-up the whole unbonded house water installation. Makes you think ?

    @kletops46@kletops462 жыл бұрын
    • Sounds like your metal pipes had no earth.

      @gteaz@gteaz2 жыл бұрын
    • There is a difference between grounding and bonding. The washing machine should have a proper ground wire that is wired to house grounded system. The flex cover should be bonded too.

      @assassinlexx1993@assassinlexx19932 жыл бұрын
  • MDPE mains supply pipe fittings could incorporate a moulded Brass metallic earth fitting easily to overcome these issues

    @Mike_5@Mike_52 жыл бұрын
  • I find the fact that this video even needs to exist and many of the comments concerning.

    @mfx1@mfx12 жыл бұрын
  • My plumber fitted a new stop tap, he used a plastic push fit connector onto the main water feed in then copper pipe then stop tap as it was live when he changed it. He left the bonding wire disconnected. Now because I have a plastic connector between the main feed and the house pipe work does it still need bonding as the old wire doesn’t reach to what’s left of the inlet feed pipe

    @TinTin-bf7ef@TinTin-bf7ef Жыл бұрын
  • There's one more issue: The whole house is at "real earth" potential unless it's built on plastic foundations. Usually that doesn't matter, plaster, bricks and carpet aren't good conductors and the area we touch them is quite small. But now you have copper pipe through your whole house that is buried in brickwork. It makes contact over a quite large surface, plenty of parallel paths---and Ohm's law on parallel connections starts to raise its head. I'd recommend to measure the resistance between "real ground" and any touchable metallic object to decide if it should be bonded.

    @HenryLoenwind@HenryLoenwind2 жыл бұрын
    • Yeah and if you do bond onto plastic water pipe (but a piece is in copper) what about the millions of gallons of water in the pipe, no one mentions this.... What do you think

      @michaelherbert2982@michaelherbert29822 жыл бұрын
    • @@michaelherbert2982 Unless your city pumps you seawater, it won't conduct anything through the plastic pipes.

      @tomcapon4447@tomcapon44472 жыл бұрын
    • @@tomcapon4447 But Tom... I got 15mm copper pipe then going to plastic.... But its full of water... Millions apon millions of gallons of water... So it won't travel through that?

      @michaelherbert2982@michaelherbert29822 жыл бұрын
    • @@michaelherbert2982 water is a awful conductor.

      @tomorichard@tomorichard2 жыл бұрын
    • @@tomorichard pure water is a bad conductor but your tap water is a pretty good conductor (because it's nowhere near pure).

      @InTimeTraveller@InTimeTraveller Жыл бұрын
  • My house has plastic pipes coming in, but I don't know that there aren't any parts of the internal metalwork touching anything conductive that's in the ground... In fact I'm pretty sure that the metal pipe to the oil tank will be connected through the combi-boiler. This old install is bonded and I'm keen to keep it that way

    @djalasdair4984@djalasdair49842 жыл бұрын
    • I also have plants touching my outside tap

      @djalasdair4984@djalasdair49842 жыл бұрын
  • What about stainless sinks with these new- fangled electric boiling water taps ? ( double insulated ? or cpc'd wiring?)

    @peterfitzpatrick7032@peterfitzpatrick70322 жыл бұрын
  • Hi Joe, I would still bond! The reason being that as water isteslf conducts electricity it becomes a return path and thefore a potential difference to the installations 'earth' value as regards an equipotential difference! Regards David

    @davidrayner4699@davidrayner46999 күн бұрын
  • Great Video

    @pchering@pchering Жыл бұрын
  • Ive just gone fully electric in my house. The gas is capped off at the meter outside my property (bungalow) there are no exposed service supply pipes exposed above ground level. All metal pipe work is now below floor leve or inside walls. My property has never had any bonding since the house was built in the 60s and ive never had any issues prior to do with fault conditions etc, but ive now been told that my electrical installation cannot be signed off if there is no bonding on both the gas and water. There is no access under the house anymore, so my question is...do I actually need to earth my gas and water if no pipes are exposed above ground level? Am I creating a new problem if I add bonding? I've had the flooring up but there is no way of running 10mm earths from the MET to the incoming Gas & Water supplies. Does this mean my electrical installation is now null & void and I wont receive a cert? Also does my install even need to be earthed taking into consideration the points above. Im having a major headache with this situation so any help or direction would be great appreciated, so I can work out a solution to my problem. Many Thanks.

    @leeguitarmcr@leeguitarmcr7 ай бұрын
    • Is the water pipe coming in to the property metal or plastic?

      @efixx@efixx7 ай бұрын
    • @@efixx Thanks for your reply. The water pipe is metal.

      @leeguitarmcr@leeguitarmcr7 ай бұрын
  • How would water hardness affect the resistivity of the water in the pipe? Can it be low enough in a hard water area to connect metal pipes in the house to metal work upstream via the plastic sections with sufficient conducance to restore the threat? Or would it be like limescale brine at that point? (in which case you might have bigger problems anyway).

    @Psychotol@Psychotol2 жыл бұрын
    • The worst i measured is 100k ohms so all good

      @MrSJT@MrSJT2 жыл бұрын
  • Joe, what if through various methods such as a gas boiler (cpc from spur), shower (cpc) introduce an earth to the water service through the cpc of the electrical system and where there is no rcd protection should the main water service pipe then be bonded?

    @mikeenglish1492@mikeenglish14922 жыл бұрын
    • Please, please will someone explain exactly HOW one **bonds** a **non-conductive** PLASTIC mains water feed? 🤔🤔🤔🤔🙄

      @boblewis5558@boblewis5558 Жыл бұрын
  • I had this situation, and inserted a 6 inch length of copper pipe for the equipotential earth bond to keep the water in the pipes at ground potential, since chlorinated water is quite a good conductor. Any better ideas ???

    @pjeaton58@pjeaton582 жыл бұрын
    • Use an RCD.

      @jemmyh2511@jemmyh2511 Жыл бұрын
    • @@jemmyh2511 Yes there are RCDs of 30mA on all 3 phases as well !

      @pjeaton58@pjeaton58 Жыл бұрын
  • JOe's analysis of the potential between the neutral at the entrance and the grounding conductor at the transformer is a bit hyperbolic. In the US NEC, there shall be a local grounding conductor in contact with the earth and connected to the ground potential terminal in the breaker box (that is the Green conductor). Bonding to the incoming water supply pipe is one method of creating a grounding connection. Other methods are to connect the earthing conductor to a grounding rod of at least 8 feet (3 meters) driven into the ground, or the attach the conductor to the metal reinforcing rods in the concrete of the foundation. (Ref. NEC-1999 article 250-C). Any non-conductive pipe shall be bridged across from the grounding electrode to the metallic interior pipes, and the exterior grounding water pipe shall be in direct contact with the earth for 3.05 meters. There is another regulation in the IRC abound the distance from the entrance of the metallic pipe to the electrical earthing conductor.

    @steveschulte8696@steveschulte86962 жыл бұрын
  • My thought is the pipe should be bonded as soon as it turns to metal inside the house; Reasons 1-Do you know the whole supply pipe is plastic? 2-i have seen supply pipes where the last foot has been converted to plastic but the rest underground is metal. I know tap water has a quite a high resistance per metre inside plastic but it would still provide a conductive path. 3-What if something is changed in the future and ended up grounding your copper pipes. Better to locate the cable & clamp than do it at a later date.

    @jdickson242@jdickson2422 жыл бұрын
  • Thank you very much for your videos, I always learn something. I understand the point of not needing to bond a system where the water enters the building in a plastic pipe. But what I struggle with is when that pipe is then connected to copper and buried in the wall to go upstairs for instant. As the walls are connected to the earth (hopefully ;-) ) would this not produce the same earth potential as if the pipe had entered the house in metal. In this scenario would you need to bond the copper pipework?

    @dvdallison@dvdallison2 жыл бұрын
    • as an example: my house is on well water and the well pipe is plastic. However, all the pipes in the house are copper so the building department calls for bonding to a cold water pipe. Granted, the copper water pipe doesn't see a direct earth ground, but there are other electrical items that do connect to the copper pipe. (heating boiler is one) Yes, it's redundant, but that's ok.

      @rupe53@rupe532 жыл бұрын
    • Why would the wall be earthed? A plastic DPC would break any earth connection, plus a wall without DPC would have to be damp.

      @johnharrison373@johnharrison3732 жыл бұрын
    • @@johnharrison373 ... the way the codes are written it's assumed anything concrete will be at least somewhat damp. (foundation, slab, patio, etc) Some codes call for a UFER. (spelling?) That's a term for a grounding system on concrete structures like pools and slabs for hot tubs. In layman's terms the rebar in the concrete needs a wired connection to a ground rod that's outside the concrete.

      @rupe53@rupe532 жыл бұрын
    • @@johnharrison373 earth potential can be and very often is picked up from pipe work in walls. The question is.. is it enough to present a danger. And that is why a test should be carried out to confirm.

      @tomorichard@tomorichard2 жыл бұрын
    • If we applied this logic all the time we would be worrying about the potential difference from stone walls internally And installation earth. The point is anything in question should be measured to see if it is extraneous to the installation as outlined in guidance note 8. Anything else is speculation.

      @tomorichard@tomorichard2 жыл бұрын
  • Joe, how long to get you in and out of the cabinets? Any pulling lube used?

    @mikecumbo7531@mikecumbo75312 жыл бұрын
    • 😂 Longer than you might think! Just relied on my natural litheness...

      @efixx@efixx2 жыл бұрын
  • gas installation pipework also plastic incoming ? The gas regs for this require bonding

    @warrenliversage@warrenliversage2 жыл бұрын
  • Most of what I was going to say has been covered below, especially Tom Capons post, but all you need to do is ask a simple question. Will bonding it make the installation less safe? obviously not, Will bonding make the installation more safe in the event of a fault? Yes it will, so you put it back. you do not know that plastic pipe has not been installed elswhere in the building that has isolated this part of the conductive pipework from other bonding at boilers, immersion heaters etc. Regs are there to provide safety( or used to be!), It is the engineers job to ensure safety, not the regs, and anything done to enhance safety is good. Mere compliance is not good enough, just an A*se covering excercise. The attitude that," the regs say I dont have to do it so I won't" is what kills people. I was trained on IEE 14th metric 1970 and have CGND Electrical Engineering. I am afraid I have little faith in the IET as the regs are difficult to understand, contradictory, and open to interpretation, which the IEE regs were not. We were trained on every regulation till we had been through the entire book TWICE, and then examined. You were allowed one retake if you failed, and then you were out of the college, and out of the industry, today, everyone passes

    @philhermetic@philhermetic2 жыл бұрын
    • Totally agree about the regs. Continual incremental changes to generate more revenue for themselves and their manufacturer sponsors. The whole book needs a complete revision with thorough proof reading to eliminate the confusing terminology (who thought up the distinctions between extraneous/exposed/equipotential ! ) and numerous ambiguous contradictions. And why the need to change section numbers at all - as if there were not enough subsection levels?

      @JC-jv5xw@JC-jv5xw2 жыл бұрын
  • actually, the issue with metal piping in the ground is just the opposite. the earth is NOT a low impedance path to ground, and the bonding network is. so by bonding metal service piping, you are bringing that piping to the same potential as your ground reference. it's not such a big deal with household voltages, but you can get a palpable voltage gradient if distribution voltage starts leaking to ground. in the US, the relevant clause in the code is to the effect of, metal piping must be bonded if there is a possibility of it becoming energized. the usual interpretation of that is that a metal fitting under a sink is not likely to be energized unless it is connected to an appliance - and the appliance will be bonded, so there you have it.

    @kenbrown2808@kenbrown28082 жыл бұрын
  • I would leave a earth bond floating around the incoming water on a new rewire just incase there is some major change to the water supply...unlikely but the hassle of not having it around is more... But not connect... and just leave in board but mark it not connected... Depends lots of variables..

    @bramcoteelectrical1088@bramcoteelectrical1088 Жыл бұрын
  • Assuming the water main in the street is cast iron which is still in quite common use, the water itself will be at zero potential. You may then have a couple of meters of plastic service pipe to the house so by the time the water gets into the copper of the domestic pipework it will not be at zero potential but still quite low. Water is not such a good conductor as copper but still does conduct otherwise why the numerous regulations re installation in potentially damp/wet areas. So if the bonding to the domestic side of the plumbing is no longer required what am I getting wrong.

    @daviddearden6372@daviddearden63722 жыл бұрын
    • A couple of meters of water in a plastic pipe will have a high enough impedance at mains voltage to be effectively an open circuit.

      @Chlorate299@Chlorate2992 жыл бұрын
  • Brilliant video, can you please explain this... If I bond onto a in coming plastic water pipe (the end piece is 15mm copper) but the water will act as earth will it not? No one's mentioned this, the fact the pipes are full of water and conduct electricity! So don't you then get the zero value?

    @michaelherbert2982@michaelherbert29822 жыл бұрын
    • Water doesn’t have a low resistance - www.aquaread.com/parameters/resistivity

      @efixx@efixx2 жыл бұрын
  • Very well put. I'm of the same mind it makes sense not to connect it but having it connected doesn't seem like it would be that much harm and would be extra insurance in-case of an unintended fault. I'm not thinking poor workmanship that should be the above all standard is that accounts for so many things. I'm thinking water heaters and boilers which are already grounded anyway having a fault or other water loving electric appliances. And well water is non-conductive in a pure state most water has some minerals in it so it wouldn't be truly nonconductive. So does this mean if I have plastic piping going to my tub I can make toast in the bath? Well apart from the GFCI/RCD.

    @imark7777777@imark7777777 Жыл бұрын
  • In the list (iv) it says central heating do you have to main bond central heating ?

    @brianwoodruff4891@brianwoodruff48912 жыл бұрын
    • If the central heating pipes are extraneous conductive parts then yes. If they're not then no.

      @efixx@efixx2 жыл бұрын
  • if you are reading from an old code book it may be required in the updated book. if you are reading from a new book then it may have been required and discontinued. the only reasons i can think of why to bond plastic pipes os. 1. a financial kickback the more stuff you have to install the more the industry makes money so maybe grounding wire and clamps cost money and it was done for money. 2. static charge certain contents may cause static build up so it was done to bleed off static. 3. ground loops if there is a section of plastic between 2 metal pipes it is to keep all the metal sections at the same level. 4. plumber was out of pipe clamps so he used an electrical clamp but if that is the case there should be no reason to connect a grounding wire. unless the code book sais that any electrical clamp in the system has to be grounded.

    @ejonesss@ejonesss2 жыл бұрын
  • I wear my seatbelt with no intention to have a crash so I'd connect it .. And seen as water is conductive what if there is a leak ? Would it then become 0v?

    @ianhadfield65@ianhadfield652 жыл бұрын
  • When the main water pipe is metal and the internal pipes are plastic, which is quite common, the few inches of metal pipe into the house needs bonding.

    @johnburns4017@johnburns40179 күн бұрын
  • Would these same regs be applied for an industrial setting?

    @JammyyFIFA@JammyyFIFA2 жыл бұрын
    • yes, BS7671 covers all electrical installations

      @codenamenel@codenamenel2 жыл бұрын
  • The argument that the only point at which the metal pipework has a connection to ground potential seems to me to be faulty. Can can imagine all sorts of other scenarios which can lead to the pipework being at ground potential. For example, what if there's a water pipe running underground to a garage, outhouse or garden tap as an example? I can imagine other possibilities. Unless you are going to check the electrical isolation of your pipework to earth with an insulation tester I would recommend bonding the water pipework to ground. I think with anything less than about 10k ohms to earth potential then it has the possibility of carrying a fatal current should something like a PEN failure cause the CPC to go to full line voltage and someone was to touch both. Also, I'm not sure that the high voltage in the vent of an earth current flowing is ever going to lead to a dangerous voltage. Metallic earth returns have very low impedance, and all breakers are meant to trip with gross overloads extremely fast. So the voltage level in the earth is never likely to be very high. 48V is a safe voltage, which is why it was used on telephone systems, and even that would require sustained current of perhaps 150 amperes or more on a typical TN-C-S system, a fault current which would have tripped any domestic MCB extremely quickly. What is a real danger is a break in the combined earth/neutral supply to the property. That is extremely likely to lead to high voltages on the buildings protective earth, and I think you will find that is the main reason why bonding of earthed pipework is so important, as in that case you do not want a very large potential difference between the chassis of a washing machine (say) and your taps and metal sink in the utility room.

    @TheEulerID@TheEulerID9 ай бұрын
  • Agree with this video but for some reason I still would prefer to bond it. Plus, isn't water conductive and technically there is a solid H2O conductor running inside the pipe which at some point will be in contact to earth via a pumping station, long shit yes but I don't entirely agree that your copper pipe is entirely insulated because you have plastic pipe. Who knows what's underground a few hundred yards away. I'm not knocking your video, you are correct, just old habits are hard to remove from the older generation. 👍👍👍👍👍

    @tinytonymaloney7832@tinytonymaloney78322 жыл бұрын
    • That's why you should test it...

      @travoltasbiplane1551@travoltasbiplane15512 жыл бұрын
    • it conducts, but if you do the maths with the equivalent resistors all is well, maybe he should do the video with the detailed maths.

      @sm1thers@sm1thers2 жыл бұрын
    • @@sm1thers no. Just measure the resistance of the part for goodness sake. If it's greater than 23kiloohms it's not extraneous. Possibly lower depending on circumstance.... No complex maths... Just knowing how to do your job.

      @travoltasbiplane1551@travoltasbiplane15512 жыл бұрын
  • Unless the incoming water supply is demineralised water then it will be conductive (If there were any more minerals in our hard water local supply, it would be supplied in sacks). Regardless of the entry to the house, some of the downstream supply pipework may be metal anyway so there is possibly still a risk. Has there been any investigation as to this being credible? Edit:- I have read some more of the earlier comments regarding water being conductive and I would add this observation based on my experiences in power stations- Demineralised water is non conductive, in fact it is used to cool HV stator windings in large alternators. Insulating pipework lies between the windings and the pumps. However, town water supply is conductive otherwise the electrode boiler (that was used for emergency use in part of the plant) would not work, as it depended on high currents passing through the water within. My personal choice would be to bond anyway, as the IET rules on earthing seem to change rather often.

    @MervynPartin@MervynPartin11 ай бұрын
  • some pipes within the house run through the ground. I.E an extension done in copper pipe that was run through the concrete. Therefor is there still a potential within the house?

    @phester28@phester282 жыл бұрын
    • then you bond that pipe not the main incomer

      @markpotter8280@markpotter82802 жыл бұрын
  • I’ve dealt with a live gas main entering properties, it’s scary stuff, deffo bond.

    @MrGuvEuroman@MrGuvEuroman2 жыл бұрын
    • Gas in Plastic?

      @scottrobinson5594@scottrobinson55942 жыл бұрын
    • @@scottrobinson5594 Yup, it works just as good as metal.

      @gteaz@gteaz2 жыл бұрын
  • The plastic water pipe is only isolated when it is dry, otherwise it is connected to ground through the water within it so any metal pipe connected to this plastic water supply pipe is grounded through the water itself to nearest conductive pipework in the ground. A ground can also be formed through a water leak. If there was a fault applying a voltage to metal pipework connected to a plastic water main there may appear to be no problem until one day there is a leak and the pipework is now effectively grounded creating a return path. This leads to a situation where it could be rather difficult to determine why breakers suddenly start tripping for seemingly no reason (possibly intermittently), people suddenly getting electric shocks in the bath or shower with seemingly no apparent fault and other anomalies. Whereas if the metal pipework was grounded the fault would be apparent straight away and not seem to disappear and then return as well as there being a ground connection that could me tested for current flow which would drastically increase the possibility of diagnosis in a timely manner and genuinely protect peoples lives.

    @DelticEngine@DelticEngine11 ай бұрын
  • My question is if the municiple side of the pipe is metal somewhere would we still not have conductivity through the water in the pipes into the earth! Thereofre metalic surfaces like water taps would still be a danger?

    @basilkatakuzinos659@basilkatakuzinos6592 жыл бұрын
  • I heard about an EICR recently that had missing earth bonding labelled as a C1. Tennants had to be relocated as the rental agency freaked out. Shocking!

    @korona3103@korona31032 жыл бұрын
    • A missing bond is a C1? Thats crazy.

      @alouisschafer7212@alouisschafer72122 жыл бұрын
    • @@alouisschafer7212 i agree its not immediately dangerous

      @andy.underwater.videos@andy.underwater.videos9 ай бұрын
  • I would still bond if it’s an existing installation or pipework. Somewhere on the pipework could be bonded to earth but not the rest of the cpc

    @glen7463@glen74632 жыл бұрын
  • bonding is there for failure a broken element in your boiler can create the whole thing to come live .. if lightning hits pipework in your loft it needs to go to ground... a modern house were all the pipeworks made out of plastic I will agree.. what your showing needs bonding

    @jayday4879@jayday48792 жыл бұрын
  • When you connect the earth to the neutral, do you neutralise the earth or earth the neutral?? If the transformer is a single phase step down transformer, I think it’s much more helpful to think of neutralising the earth. Voltage is always the potential between two points and therefore the earth is only at 0 V potential if it is locally bonded to the neutral.

    @TimmyBoja@TimmyBoja2 жыл бұрын
    • The use of the terminology of "neutralising" is not conventional and is not used. Keep away from it. It you are not using the right terminology, then the question is, is that because the user's knowledge is limited?

      @deang5622@deang5622 Жыл бұрын
    • @@deang5622 I use the word "neutralise" because invokes a change of perspective. It means to make neutral. Neutral is defined in the front of BS7671. Earthing is used throughout BS7671 but in my experience most people seem to think that the Earth has magic powers. It doesn't. NB: "magic powers" is not defined in BS7671 but can often be used synonymously with "magnets"

      @TimmyBoja@TimmyBoja Жыл бұрын
  • What about a metal radiator in the bathroom, or a dual fuel towel rail. RCD protection is this in place. A metal bedrame sits in the middle of a floor. I would bond it for bathroom protection even with RCD.

    @brianoneill350@brianoneill3502 жыл бұрын
  • Depends on what sort of floor the house has, if it's soil under boards like in an old terrace, there's a chance of pipes resting on the soil even if the income is pvc. Then there's a chance of the floor being unfilled and concerted to stop pooling surface water on the surface.

    @madhatter61@madhatter612 жыл бұрын
  • If a lead water pipe was swapped out for mdpe, would bonding the old still be worth it?

    @b21playa@b21playa Жыл бұрын
  • Great vid I’m sure, but things appear and one doesn’t see them appear ( or at least I didn’t ) a flash or a circle ⭕️ maybe pulsating would help the less canny amongst us, ..😊

    @royharkins7066@royharkins70662 жыл бұрын
  • What about gas pipes this too is poly pipe to the house is bonding required or not ? Or …..

    @TheALan556@TheALan5565 ай бұрын
  • More vids from under the sink please, this could be a feature

    @nigeltiernan1473@nigeltiernan14732 жыл бұрын
    • 😂 good idea 👍

      @efixx@efixx2 жыл бұрын
  • What if metallic water pipework entered the mass of earth elsewhere in the system after the incomer? I would be bonding then! Think properties with annexes or external water taps… etc.

    @aidanroutledge6157@aidanroutledge61572 жыл бұрын
    • then you would bond it there, if a property has two or more points where the pipework enters the building you would bond at each point it doesn't happen a lot but I have seen it. For example a house has a main water supply that is metal coming into the property from underground into the kitchen but then it also has a metal pipe going underground from the wc to an outhouse you should bond at both locations within 600mm before any joints yada yada yada

      @markpotter8280@markpotter82802 жыл бұрын
    • @@markpotter8280 agreed. old pubs with cellars are notorious for metallic water pipework re-entering earth after the incomer which has been replaced with a new plastic incomer. Important to review all extraneous systems and not just assume based on incomer.

      @aidanroutledge6157@aidanroutledge61572 жыл бұрын
  • Would still need bonding if copper pipes went underground at any point after, e.g. to an island kitchen sink, heating pipes set in a concrete floor or going out to an external detached building assuming TNC-S system

    @waynio67@waynio672 жыл бұрын
    • Agreed. Re-entrant pipework.

      @travoltasbiplane1551@travoltasbiplane15512 жыл бұрын
    • Any copper SHOULD be bonded. if there is a break with plastic both sides should be bonded

      @gowdsake7103@gowdsake71032 жыл бұрын
  • I would bond internal metallic pipes because of the risk of they being in contact to the line conductors at some point. That should not happen in a well done electrical installation, but accidents happen and there are bad electricians who will leave wires exposed near metallic pipes.

    @vitorao@vitorao2 жыл бұрын
  • Think the question should be , is the internal pipework an extraneous conductive part or not.

    @johnupton9175@johnupton91752 жыл бұрын
  • In the sketch he says the water pipe could be lower resistance than the earthing, however the pipe has to connect to the earthing bond of the transformer to make a circuit, no way can it be lower as it is connecting to the same bonding on the transformer. It can be equal to the earthing or higher but not lower

    @tonysheerness2427@tonysheerness24272 жыл бұрын
  • I'd bond it anyway because you have no way of knowing if the homeowner has installed a metal pipe elsewhere that exits the building, to an outhouse etc. If there was no plastic between that and the incoming metal stopcock then the pipework would then all be at earth potential. You could argue that that shouldn't happen but it's unlikely that a home diyer or plumber would consider that and possibly neither should they have to - it's the electrician's job to ascertain that and plan ahead for it. You mentioned a possibly scenario for not including bonding because it shouldn't be relied upon to prevent danger where other regs have been violated but then surely that is the same for a metal pipe coming in. The earth bonding is there to provide a path back to the panel in the case of a fault which could occur even with a plastic pipe entering, such as driving a nail through a pipe and cable at the same time... I'd say the difference would be that the bed can be moved but the pipework cannot be so should be bonded. You could argue though that the bonding could occur at the most convenient location and not necessarily within the regs distance of entry to the building...

    @smitcher@smitcher2 жыл бұрын
  • And if that pipe feeds an electric shower? And how tight is the mains earth terminal on the shower?

    @sundog486@sundog486 Жыл бұрын
  • If there is any earth leakage current wouldnt the RCD trip ? (Residual currect device.)

    @markkennard861@markkennard861 Жыл бұрын
  • Even tho the water pipe entry is plastic, the copper pipes in the house come into contact with all sorts and if you measure a resistance to earth, then it may need bonding.

    @andy.underwater.videos@andy.underwater.videos9 ай бұрын
  • In the case of an earth fault within a piece of equipment, wouldn’t there be an over current or RCD trip which removes the danger?

    @Orgakoyd@Orgakoyd9 ай бұрын
  • Agreed, no need to bond, no point at all. I have a new build, plastic pipe and bonded anyway, I thought builders were all about saving any money they could?!?

    @oliverriall@oliverriall2 жыл бұрын
    • Misinterpretation of regulations is a really big problem - they're written awfully and sometimes the training is just as bad.

      @Chlorate299@Chlorate2992 жыл бұрын
  • Does the sink require bonding?

    @ia4387@ia4387 Жыл бұрын
  • A PEN fault will promote an alternative return path for neutral current through any extraneous earth connection ie metal water or gas pipes, either from the property affected or as a bypass through a property from an adjacent property on the same supply. Plastic service pipes do at least prevent a dangerous rise in main earth current due to PEN faults. They are more common than you think - check out Team Electrical podcasts 1 and 2 on Diverted Neutral Current. We are not taught to think critically so we expect the DNO head to be whatever it appears to be. Today most service heads are TNC-S and not TNS because somewhere outside the property a repair to the old PILC cable will have made the supply TNC-S. The only exception might be in a rural area where supplies are mostly fed overhead.

    @stevejagger8602@stevejagger86022 жыл бұрын
  • In the US it does require bonding. The water in the pipe is not pure, therefore it is conductive. It goes through a metal pipe in the earth somewhere. That is why we ensure all metal pipes are bonded on the US. If metal water pipes are separated by plastic pipe we have to bond both sections. Note to those who would argue with me about the water not being pure: When I say it is not pure I am not talking about how safe it is to drink. Safe to drink is a different metric as compared to purity. Tap water contains minerals. It is not pure H2O until it is distilled. All drinking water and residential tap water has minerals in it.

    @ianbelletti6241@ianbelletti62412 жыл бұрын
  • One more point. If there is a potential between the metal pipes in your house and the installation in your waterworks / street installation, insulated by some plastic pipes in between, electrolysis will happen, and fill your pipes under high pressure with a highly combustible mixture of O2 an H2. Even with no ignition this might damage your water installation.

    @matekochkoch@matekochkoch2 жыл бұрын
    • Electrolysis!!?? Please explain! DC, not AC, is required for electrolysis! 🤔🙄🙄🙄

      @boblewis5558@boblewis5558 Жыл бұрын
    • @@boblewis5558 Electrolysis doesn't care AC or DC - it will happen.Normally DC is used to separate both gases O2 will raise at the positive pole and H2 at negative. With DC this will change 50 or 60 times a second and you get a perfect mix of O2+H2 for maximum bang at both sides.

      @matekochkoch@matekochkoch Жыл бұрын
  • It best to disconnect the bonding cable entirely as with no connect to earth at the water pipe it makes it worse, you then could have live cable from your CU to....you! Or your copper pipe work onwards from the MDPE....but hey if that happens you won't get limescale ?

    @stephencoulthard1718@stephencoulthard17182 жыл бұрын
    • Hooking up the bonding in the CU is one of the worst ways, in my opinion only a "crutch", a better than nothing solution. There are better methods. For example here in Germany all bonding wires go to a central "potential equalisation bar" in the house. That is hooked up directly to the PEN in the service entrance box (TN-C-S), or the earth electrode of the building (TT). In most cases you got both here, since it is mandatory to have an earth electrode here in buildings errected after 1980. Even in TN-systems. In older buildings the incoming water pipe was designed to serve as an earth electrode, but since the cities here replace their old thick cast iron piping with plastic that won't work anymore. We called that "supportive earth electrode" to keep the voltage of the PEN close to real earth potential. And it also lowers the touchable voltage in case of a PEN fault. That's what this bus bar looks like: de.wikipedia.org/wiki/Potentialausgleichsschiene#/media/Datei:Potenzialausgleichsschiene.jpg www.amazon.de/DEHN-563050-Stange-Schiene-mm2/dp/B001Z5Z0B8/ref=sr_1_3?__mk_de_DE=%C3%85M%C3%85%C5%BD%C3%95%C3%91&crid=3WFSDTH391HE&keywords=potentialausgleichsschiene&qid=1636401777&sprefix=potentialaus%2Caps%2C176&sr=8-3

      @Marcel_Germann@Marcel_Germann2 жыл бұрын
    • If the bonding cable developed a fault would you, stood in shoes on your kitchen tiles, be an easier path to earth than the plastic pipework? I'm an apprentice and curious :)

      @electricalstuff259@electricalstuff2592 жыл бұрын
    • @@electricalstuff259 it is about difference between you and what you are touching Vs what you touch with another part of your body....you only need 50ma across ya heart to die...the bigger path of resistance the better. Best not to touch stuff with left hand or both at same time:)

      @stephencoulthard1718@stephencoulthard17182 жыл бұрын
    • @@stephencoulthard1718 Threshold for a healthy adult is 30mA, for kids and elderly people (especially with heart issues) it's even lower than that.

      @Marcel_Germann@Marcel_Germann2 жыл бұрын
  • Most likely the system beit gas or electric that's heating the water will be also bonded so in affect your piping will be bonded however I would bond it anyway just in case something were to accidentally come in contact or in the future say somebody runs a new supply line in that's copper unlikely or an out outside tap with copper. But that's my opinion and I'm living in a house where there's a ton of copper piping and it's not bonded because the income is plastic.

    @imark7777777@imark77777772 жыл бұрын
  • Is there any point in connecting to the outside of a plastic water or gas pipe? The plastic is an electrical insulator after all.

    @frankmitchell3594@frankmitchell35942 жыл бұрын
  • As almost every gas supply is of MDPE one can only assume no bond to gas is required..or is it?

    @ronbladon7833@ronbladon7833 Жыл бұрын