How to Wire an Electrical Panel - Good Workmanship

2024 ж. 17 Мам.
233 345 Рет қаралды

#sponsored
Watch Dustin from Electrician U as he demonstrates how to wire up an electrical panel in this detailed video. Whether you're an experienced electrician or just interested in the craft, this hands-on look at materials, organization, and best practices is worth a watch. 🛠️🔌
00:00 - Intro
00:11 - Materials - What kind of panel, breakers, wire and connectors used
02:21 - Logic of how to lay out a panel
04:15 - Demonstration
10:09 - Using Ty-Raps to keep everything neat and orderly
12:10 - How many conductors can fit in each connector?
12:59 - Alternative way to secure your main feed
16:44 - ABB Ty-Raps
17:09 - Electrician U Membership ⬇ Sign up below ⬇
17:59 - Demonstration Continues
19:00 - Did You Know: How to apply NOALOX properly
20:07 - Demonstration Continues
21:15 - Why would the inspector fail you?
In this demonstration, Dustin takes on the task of wiring an electrical panel, covering every detail from beginning to end. Starting with an overview of the materials including the type of panel and breakers, NM Cable, "Romex", #12's, 8's, and 6's, he highlights the importance of keeping everything organized and neat. The layout of the panel is crucial, with emphasis on grouping arc-faults circuits, 220 circuits, and ground-faults circuits.
The main part of the video focuses on hands-on techniques, starting with a personal touch of using scrap wire to keep the conductors from being unruly, followed by cutting off the sheathing, and taking extra care with wire management. Dustin shares a special technique using Ty-Raps that are listed to be used in electrical environments, showing how to organize and tuck away the grounds with ABB's Ty-Raps. Special attention is paid to conductor fitting, securing the main feeder using Ty-Raps, and the proper application of NOALOX. The tool provided by ABB tightens and cuts the Ty-Rap, leaving no sharp edges, ensuring safety and quality.
Wrapping up, the video explores potential pitfalls and how to avoid inspection failure. Tips include double-checking work, ensuring proper torque settings on the lugs, not double lugging on the neutral or ground bus, and ensuring wires are stapled securely. The demonstration emphasizes the importance of precision, care, and adherence to code.
🤘⚡️EU MEMBERSHIP⚡️🤘
Sign up here --- www.electricianu.com/electric...
JOIN ELECTRICIAN U - become a member and get:
Premium Members-Only Videos
Monthly Deep-Dive Courses
All of our Practice Exams
300 Question Code Cannon
Weekly Lesson Emailed to You
Private Members-Only Discord Channel
🎓💡CONTINUING EDUCATION💡🎓
Sign up here --- www.electricianu.com/continui...
State Approved
Video Based
✍📝PRACTICE EXAMS📝✍
Sign up here --- www.electricianu.com/electric...
Timed Online Residential Wireman Exam
Timed Online Journeyman Exam
Timed Online Master Exam
300 Question Online Code Cannon (not timed)
Take as many times as you want
All of the above come with printable PDFs
🎤🎧PODCAST🎧🎤
Spotify:
open.spotify.com/show/7ldCwdx...
Apple Podcast:
podcasts.apple.com/us/podcast...
📱👍SOCIALS👍📱
TikTok - / electricianu
Instagram - / electrician_u
Facebook - / theelectricianu
Reddit - / electricianu
Rumble - rumble.com/c/ElectricianU
LinkedIn - / electricianu
🎧🎹Music, Editing, and Videography by Drake Descant and Rob LeBlanc🎹🎧
#tyrap #ABB #installationproducts #electricalcontractors #electricalindustry #cabletie @ABBInstallationProducts

Пікірлер
  • Refreshing to see someone that takes pride in their work

    @delaney3722@delaney37228 ай бұрын
    • I rarely come across neat panels , I don’t get it

      @mitchlosier@mitchlosier8 ай бұрын
    • Agreed it’s surprising how little extra and sometimes less time it takes to be near and tidy

      @aidanhodgkinson5586@aidanhodgkinson55868 ай бұрын
    • Workmanship!!! Yay!!!

      @qcoats@qcoats7 ай бұрын
    • @@mitchlosier Most companies don't have the manpower and time to let someone just sit in a panel and make it really pretty for a few hours. Also in a commercial setting no matter how pretty you make it eventually some knucklehead will come behind you and undo all your hours of work with a couple snips of their side cutters. I have a feeling it's residential guys that are spending this much time in a panel and that I can understand but I think it's something that you don't see in a commercial setting because it wastes a lot of time that you could be applying to something else.

      @ogvicodinmuncher@ogvicodinmuncher7 ай бұрын
  • Retired plumber here, fantastic workmanship. I treated my work the same way, I wish I had a dollar for every time a fellow plumber said to me "Why are you making everything so perfect? No one's gonna see it when the drywall is up!" Pride in one's work.

    @franktrig@franktrig8 ай бұрын
    • You can be proud of your work if it isn’t pretty too.

      @josue24@josue245 ай бұрын
    • Theres a reason they said that... Made them feel bad. Also, they were probably only concerned with time/money.

      @LevizGibson@LevizGibson3 ай бұрын
    • That's the same way I feel about my work! I feel everyone of my jobs has my name on it. I always like to leave some extra wire, at least a couple of inches, for just in case oppsys lol! You can still make it look nice and have the peace of mind!

      @rshoe1023@rshoe10232 ай бұрын
  • A thought about not using the wire brush as instructed... I think the manufacturer specifies a wire brush or emery cloth because they're both able to abrade aluminum oxide and get the NoAlOx in contact with bare aluminum. A nylon brush isn't capable of achieving this. Besides, using a nylon brush instead of using a wire brush, as specified by manufacturer, technically means that practice isn't code compliant. I've found a 4-in-1 plumber's brush to be really handy for quickly working NoAlOx into the ends of large conductors Thank you for making this video, I picked up quite a few tips to make my work cleaner :)

    @brianlink5379@brianlink53798 ай бұрын
    • Yes indeed. I see so little common sense on this topic. Aluminum oxide forms in milliseconds after the surface of the aluminum is disrupted. One could then argue that this minimal oxidation that occurs is surface an unlikely to lead to a significant increase in resistance if NoAlOx was applied right after. But I like what Dustin and manufacturer recommends. Get it in between the strands. Aluminum oxide is tough stuff. Maybe the wire brush and emery cloth remove a little, I don't know, but probably not much. What is going to remove it is tightening up the lug and forcing those strands to rub up against each other and the screw under a lot more pressure. The the NoAlOx sort of seals the deal by keeping oxygen in the air from getting to those newly abraded surfaces.

      @r7j7t7@r7j7t73 ай бұрын
  • That wire management is amazing. Great job!

    @OnePakkuMan@OnePakkuMan8 күн бұрын
  • New apprentice here; your videos and podcast have been such a blessing to better my work even at such a basic level!

    @james.istafford3481@james.istafford34818 ай бұрын
    • Agreed.

      @skatercurator@skatercurator7 ай бұрын
  • I've been an IBEW journeyman for over 40 years and I agree with 95% of what you showed. However, I have encountered both main, branch circuit breaker and buss tab failures that have required relocation of the breakers. With the mains, the issue was with conductor damage due to loose connections requiring cutting back an inch or so of the conductors. We were taught to make a circular loop that exceeds the code minimum requirement to facilitate that need. With the breakers, I have sometimes encountered situations where a buss tab has been damaged beyond use and a new breaker must be relocated elsewhere in the panel as that tab is no longer usable. I was taught to always leave a neat loop long enough to reach any position on that side of the panel. I've been using a Brady shrink tube labeler for wire ID for years, highly recommend it. I concur with others about spacing breakers that can generate heat to help extend their life. The last thing, and oh so important, is to do load calculations to balance the main feeder loads equally.

    @cayankeelord3730@cayankeelord37307 ай бұрын
    • Great suggestion re: the labeller. What size do you use (e.g., 0.75", 1"...) and which type (vinyl, polypropylene)?

      @ncooty@ncooty4 ай бұрын
    • another reason for the loops or mouse ears on SE conductors is to prevent any water that could accidently travel down the cable to go directly into the lug and down the bus ,and then the breakers , the loops allow the water to drip away from the lugs and bus , i do the same practice especially in a meter socket . The most puzzling to me is the use of the bushing on the connector , why thats code is beyond me , pulling into a pipe yes absolutely but into a connector kind of a unnecessary .

      @DeltaCo7175@DeltaCo71754 ай бұрын
    • @@ncooty The Labeler: I'm not sure of the type. My employer bought a whole new system and offered me the old one. It came with a couple dozen boxes of both labels, shrink tubes, transfer "ink" of various colors, the PC link cable and CD with the program on it. You don't need to use a PC to enter data into the unit, but it makes it easier to setup and how it prints, i.e.- Type size, vertical or horizontal, font type, consecutive numbering, etc. The unit will store several different print jobs so when you're out in the field you can pickup printing consecutive numbering where you left off or modify the print data. If you do a lot of motor control, data or any other type of job requiring labeling ID's it's great to have.

      @cayankeelord3730@cayankeelord37304 ай бұрын
  • I recently replaced an existing panel with an updated one. I tried my best to keep it neat (thanks to your videos). But it was impossible to put breakers in an orderly fashion as is the case with a new build. I would like to see a video of how you would tackle a similar situation. Also power is coming in from bottom as well as several branches. Thanks again and keep up the good work!

    @stevesargent4269@stevesargent42698 ай бұрын
  • Excellent work. I wish more tradesmen took as much pride in their finished product. There are a lot of similarities between this and wiring an industrial control panel. One thing I tell new guys is to watch the "flow" of the wiring to keep things from crossing any more than absolutely necessary. I use painters' tape for temporary tags on the wires above then put heat shrink labels on the panel wiring.

    @tomygun1585@tomygun1585Күн бұрын
  • How do you keep track of which wires are for which circuit when you strip all the romex sheaths at once? I have wondered this for a long time.

    @lukebenson6264@lukebenson62646 ай бұрын
    • if I had to guess, diagram what each hole in the breaker box has which wires and in what order. Since they are secured that placement shouldn't move even with stripping the sheaths.

      @Circle14@Circle143 ай бұрын
  • New student. Just started my night classes in September. Waiting until probably after the set of classes to find an apprenticeship. This is all so new to me…..but I’m enjoying learning all of this so far! Thanks again, Electrician U.

    @Mr_Gray_1995@Mr_Gray_19956 ай бұрын
  • Wow. I wish every electrician would aspire to install as cleanly and neatly as you have here. Well done sir

    @roberta5948@roberta59488 ай бұрын
  • Amazing setup. I'm not an Electrician... but I love seeing somebody take pride in their work.

    @TomSnipes@TomSnipes8 ай бұрын
  • Loved the feeder nail trick. Brilliant

    @imabeapirate@imabeapirateАй бұрын
  • Watching electrician u makes me want to be an electrician

    @Motherclucker369@Motherclucker3697 ай бұрын
  • Wow, that is one of the cleanest panel I have ever seen ! Nice !

    @billyr9840@billyr98408 ай бұрын
  • Dustin, what about a video on load calculations and how to do them? I know some people have struggled with that and the Code book doesn’t do a very good job of breaking it down to where that most beginners/apprentices can understand how to do it. Thanks.

    @deboard_masonlee1028@deboard_masonlee10288 ай бұрын
    • Great suggestion,I know Mike holt has good info on that portion of code 220, and his material is being used in my masters electrician prep class for the exam

      @nickduggan3084@nickduggan30844 ай бұрын
  • You make no mention of balancing, All the 240 volt breakers on one side of the panel, is fine because by their nature, they balance the loads automatically. But when laying out the single pole breakers, do you look to try to balance at this point, or wait until panel is fully operational?? I didn't notice you terminating the breakers, so my question is if you provide a "slack loop" to easily allow moving breakers up or down to aid in load balancing? I used to use the idea of loads going down past the probable breaker and looping back up, before turning to connect to the breaker. Being able to move a couple slots up or down usually allows for adjusting breaker order. But I have seen guys leave enough slack to get to anywhere in the panel too. How do you usually do it?

    @professorg8383@professorg83838 ай бұрын
  • Beautiful, I love it when the panel looks like yours does!

    @tomnielsen3661@tomnielsen36618 ай бұрын
  • If only all electricians did a clean job like this.

    @dirkmanderin@dirkmanderin3 ай бұрын
  • Amazing! helping other/future electricians with tips, explanations , things to know/consider and tutorials.

    @JP-zk7ye@JP-zk7ye8 ай бұрын
  • Beautiful install and explanation.

    @tristanschaper281@tristanschaper2818 ай бұрын
  • that tool cutting the Ty-Rap is very cool

    @ziirsaalim@ziirsaalim5 ай бұрын
  • Bro I’ve been following you a long time. I can’t tell you how much you’ve taught me. I’ll never stop learning and really appreciate that you share your knowledge with the world. God bless you, and stay safe and please keep the content coming! ❤

    @stevensmithjr9014@stevensmithjr90148 ай бұрын
  • Taking pride is NEVER A BAD THING!!!! Fantastic!!

    @reginabivona1282@reginabivona12828 ай бұрын
  • Beautiful work! I am impressed!

    @brianbeasley7270@brianbeasley72708 ай бұрын
  • Great video bro!! You explain how to do electrical work very well. I’ve been watching your videos for about three years.

    @atmtim3783@atmtim37838 ай бұрын
  • Very thorough presentation. I learned a lot. Thank you for sharing your knowledge and expertise .

    @vince6829@vince68298 ай бұрын
  • Love your content brother! Keep these types of videos coming!

    @Taylor1147@Taylor11478 ай бұрын
  • I'm doing my own install in my garage, and this - by far - is the best out of maybe 100 youtube videos i have watched about panel boxes.

    @purposefully.verbose@purposefully.verbose6 ай бұрын
  • The GOAT!!!!

    @captainwaring@captainwaringАй бұрын
  • Truly nice work.

    @0blivioniox864@0blivioniox8648 ай бұрын
  • Dustin, THANK YOU!!! every lil detail matters and your content is very planned/thought out!

    @carolinafrog4365@carolinafrog43657 ай бұрын
  • Awesome! Your work is beyond “neat” it’s beautiful. I thought I was anal about neatness but you just took it to a whole new level! Thanks. Love your videos.

    @sasines@sasines8 ай бұрын
  • Awesome work.. been watching your videos for almost a year while I've been in EEST training. Always detailed and for the most part I actually understand what you're talking about 😂😂. Thanks for what you do‼️

    @muddrunner81@muddrunner818 ай бұрын
  • I admire your work brother 👍

    @omarbendix2647@omarbendix26478 ай бұрын
  • I like the mention of the torque marks. I've watched a lot of other videos and haven't seen anyone mention this. It's used often in the telecom industry that I've working in but not in these residential type install videos. Permanent sharpie and for RF and large ground bars we have used red tshirt 'puffy paint' that shows up well in close out photos or feet away and partially breaks off once the connection is moved.

    @ullrsdream@ullrsdream8 ай бұрын
  • Very well done panel, Dustin. Really like the name tag sleeves you put on your conductors for ease of clarification

    @iansavoury4746@iansavoury47468 ай бұрын
  • Great primer as I am going to place a panel and meter base for power to my workshop.

    @joeolejar@joeolejar4 ай бұрын
  • Great, thanks for sharing. Keep creating more content like this one

    @shawnshawn911@shawnshawn9118 ай бұрын
  • This is next level OCD, nice work, always appreciate good electrical work

    @SCIFIaction@SCIFIaction5 ай бұрын
  • Now, that's a neat panel!

    @tomtillman@tomtillman8 ай бұрын
  • I’m not an electrician but do some repair work on my home and other family homes. I have had some training, enough to do the things that I do, and have been formally trained in electrical safety. I never re engineer anything, just replace. So I really enjoy learning from you and your lessons have been very valuable to me. Thanks for what you’re teaching.

    @patbullard9276@patbullard92768 ай бұрын
    • Beautiful panel Gives me a template for quality Thank you

      @Jim-zb1lu@Jim-zb1lu8 ай бұрын
  • Great video this guy is a pro

    @josecabrera6391@josecabrera63918 ай бұрын
  • More of this please!!

    @madpacket@madpacket8 ай бұрын
  • Running down right now to mark the lugs in my subpanel with a sharpie. Inspection in a few days. Thanks!

    @FallLineJP@FallLineJP6 ай бұрын
  • I didn't know that electrical wiring can be so nice and tidy, I can see that you really like what you do. Thank you for your video, now I have a more clear vision of how an electrical panel looks (not just on a plan/drawing)🌸

    @TagachisTroll@TagachisTroll3 ай бұрын
  • Im finally sparkying sparky. Spent the last year apprenticed under an electrician with high standards and amazing skill, my son in law. Your panel here looks alot like my first panel did, so this video is just extra verification that my boy is doing it how it should be done. Thanks for your work and im gonna be nerding out from here on your content.

    @IncarnateUnlimited@IncarnateUnlimited8 ай бұрын
  • Top notch all the way through!

    @timothysears6970@timothysears69708 ай бұрын
  • I love your videos man, keep it up!!

    @siozer321@siozer3218 ай бұрын
  • I went into a government building once, to do a safety inspection, and saw a panel at the top of the wall, right at the 20-ft ceiling. The government doesn’t pull permits, and the road crew had added their own new lights. When I first saw it I thought it was j-box. But after getting a ladder to climb up and check, they had a sub panel with eight 20-Amp breakers, and the ground and nuetral bonded. I made them hire a licensed electrician to clean it up. Three months later I went back to verify the inspection, and they had put a work bench under the new panel. I made them move the bench, and mark a clear zone, in yellow traffic striping paint. It will be bright reflective yellow, “KEEP CLEAR - NO STORAGE”, until the concrete gets torn out.

    @randallthomas5207@randallthomas52078 ай бұрын
  • New subscriber here, so happy to have found your channel. I'm a licensed swimming pool contractor in Central Florida. I specialize in automation and equipment troubleshooting. Lots of electrical involved and I absolutely love it. Your channel is very informative. Keep up the great content!

    @pooldoctorofclermontinc5788@pooldoctorofclermontinc57888 ай бұрын
  • Good workmanship.

    @abdulseaforth6930@abdulseaforth69304 ай бұрын
  • I love it. Thanks for sharing.

    @thespencerowen@thespencerowen8 ай бұрын
  • Great demonstration. Some of the basics that I have seen are not really trained into new electricians. Love the grounding at the bottom. And that is really helpful when you need to add new circuits in the future. I think you could’ve spent a little more time on circuit labeling, but all in all great job.

    @jamesnewsom5899@jamesnewsom58998 ай бұрын
  • Looks awesome!!

    @justinvanburen8259@justinvanburen82598 ай бұрын
  • Awesome. Great work.

    @thewhiteknight02@thewhiteknight028 ай бұрын
  • Great video in detail, thanks Dustin!

    @gustavovaldez8033@gustavovaldez80337 ай бұрын
  • Great job! That panel work is excellent looking!

    @johnvanwinkle4351@johnvanwinkle43514 ай бұрын
  • Excellent work.

    @wayneweis653@wayneweis6534 ай бұрын
  • My wife had the todays show on, I saw you on TV brother. Way to make electricians known!

    @brandonpetrille@brandonpetrille7 ай бұрын
  • Big fan of your videos! Thanks for all you do

    @jlk082577@jlk0825777 ай бұрын
  • Very clean.

    @erikkarling2176@erikkarling21768 ай бұрын
  • Another great video with tons of detail.

    @SRCardow1@SRCardow14 ай бұрын
  • Sparky need to learn how to service loop those pigtails so it looks awesome, showcases his skill, shows the effort, and future proofs a breaker move. That’s the ultimate brother. Shorten but leave some.

    @pn102@pn1028 ай бұрын
  • Learned a lot of good tips from this video!

    @dansklrvids7303@dansklrvids73034 ай бұрын
  • Dustin you do clean work and I like that. I'm the same way with my plumbing, I've been a plumber for 51 years so when I see work you are doing I take notice. I watch other trades doing their work and not many do as well as you do. You're a Texas electrician and I'm a Alabama plumber. Yes we are both Southern Boys...haha

    @barrymilam9665@barrymilam96657 ай бұрын
  • Great video! One other code tip is the bottom of the panel has to be at least two feet from the floor.

    @kristopherb8046@kristopherb80468 ай бұрын
  • Awesome information! I was always told to leave it nice for the next guy - that guy might be you!

    @JeepinMaxx@JeepinMaxx8 ай бұрын
  • Great presentation thanks

    @mhick3333@mhick33333 ай бұрын
  • I’ve been an electrical contractor for years. I’m annal about workmanship. Rarely do residential work anymore, but my/our panels always look like a draftsman drew them. Some of your techniques dovetail with mine, minor differences, but I would allow you on our team. That was meant to be taken as a compliment. We always land our grounds and neutrals first towards the outside of the panel. Our ungrounded conductors move in slightly towards the center/breaker so we have a tier effect. We also zip tie into neat bundles. I’ve also used the technique of zip tying cables to staples, depending on the circumstances. Enjoyed your video!!!

    @montyedgar6409@montyedgar64094 ай бұрын
  • Great Video upcoming electrician going to school in January

    @stonedsocrates7499@stonedsocrates74997 ай бұрын
  • that is genius with the staples and strap....I thought you were going to say " two hole strap"

    @Robsemail001@Robsemail0018 ай бұрын
  • Great Video. Thank you for sharing. I would like to see commercial panel install

    @zekenzy6486@zekenzy64868 ай бұрын
  • I use Eaton panels and I can’t find feeder lug covers for the panel. It’s a bit frustrating. It was nicely done and thanks for the tips.

    @MrKen59@MrKen598 ай бұрын
  • As nice as it is to keep all the arc faults and combos and gfcis together to keep uniformity, they tend to radiate A LOT of heat, causing them to go bad fast. I run into that a lot in new builds in Dallas. I've started to stagger just to give the other breakers more life.

    @braydonhaddock6430@braydonhaddock64308 ай бұрын
    • I agree with this comment.

      @bdhost07@bdhost078 ай бұрын
    • I was surprised to see that. I was always taught to stagger the 220s

      @oskytel3780@oskytel37808 ай бұрын
    • I always heard breakers with most draw at top of panel to get rid of heat and low draw at bottom.

      @ranger178@ranger1787 ай бұрын
    • They don't radiate a LOT of heat, no more than a standard breaker. Current flow is what generates heat, not the fact it's a breaker than contains electronics. Current flow generates heat through all breakers, staggering does nothing..

      @pld8993@pld89937 ай бұрын
    • @@ranger178 Doesn't matter where the breaker is as the buss bars are designed to handle the heat generated by any and all breakers wherever they are.

      @pld8993@pld89937 ай бұрын
  • Dude, you’re amazing!

    @rbs427@rbs4276 ай бұрын
  • Awesome. Thank you very much

    @roberthickoxjr@roberthickoxjr8 ай бұрын
  • Great vid!

    @elliottheyne7007@elliottheyne70078 ай бұрын
  • Very nice work ,love square D

    @superrushfan3@superrushfan38 ай бұрын
  • What do you think about the lock ring wrenches. I find I'm able to get a much tighter connection and my inspector really appreciates it.

    @christopherderrick2923@christopherderrick29237 ай бұрын
  • Good job man !! I have been out of the game for about 10 12 years, do they not make 220 volt GFCI/ AFCI for plug on neutral?

    @lesterwatson8519@lesterwatson85198 ай бұрын
  • Very Nice Job

    @josephspina9547@josephspina95476 ай бұрын
  • When I worked as an electrical helper in the early 2000’s no one was allowed to use a knife of any kind. We were instructed to use the string inside the insulation or the ground to strip the insulation and snip it off. It was industrial work at a DuPont plant.

    @stumpbumpers@stumpbumpersАй бұрын
  • GREAT STUFF

    @ephraimsilberberg708@ephraimsilberberg7083 ай бұрын
  • Very nice... Good workmanship indeed! Trade craft...

    @hmrody@hmrody3 ай бұрын
  • Nice job

    @SFoley990@SFoley9904 ай бұрын
  • Dude I wish I could have you as a journeyman.

    @Lucifaar@Lucifaar2 ай бұрын
  • 8:09 mark. You should always square off your wires with a minimum radius of 4 times the thickness of the wire. I like to use my index finger to make the bend radius. If you bring wire straight out from the breaker with a slight bend towards back wall of the box, and then bend up 1/2" from the side wall of the box and then back in towards the buss bar using index finger again to make the radius it will be a much cleaner install. Reverse order when landing your hots or neutrals that land on the breaker. Also a good rule of thumb when installing neutrals and grounds is land your wire in descending order as you terminate to your breakers. So top Breaker #2 (breaker space #6 in your case because of the surge protector you put in. So maybe start 3rd terminal down in case of future add and relocation of the surge protector.) would have neutral on top terminal of inside buss bar, its ground would go on top terminal of outside buss bar. On down the line. Then if you have to remove a circuit wire for whatever reason later on it is easier to find the ground and neutral wire that goes with its hot wire. Always think of the next guy when you install something to make it easier to trouble shoot, change or fix. The next guy just may be you.

    @1rtt1@1rtt13 ай бұрын
  • Awesome!!

    @robertfalcone3780@robertfalcone37808 ай бұрын
  • As always, why this guy only have 500K subs? People needs to start following professionals. I've seen countless of DIY'ers that know nothing about anything, or "handymans" with more subscribers. That is a cancer to the trades.

    @b01brdcst@b01brdcst8 ай бұрын
  • Duston, how do you identify your home runs when pulled? How do you preserve that identification as you rip out the Romex and then land the wires where they go? Do you use any system other than a sharpie to do your panel directories?

    @walterbordett2023@walterbordett20238 ай бұрын
    • A good way is to label the cable above the panel, at the end of the cable, and in between. I also think using a labeler is a neat way to do the panel directory.

      @illestofdemall13@illestofdemall138 ай бұрын
    • one electrician told me the sharpie disappears on the plastic jacketing after years the plastic chemicals fade it, he went back to a house and all the markings had disappeared. @@illestofdemall13

      @ranger178@ranger1787 ай бұрын
  • Not an electrician, really just trying to build my knowledge, but that just looks so organized and aesthetically pleasing. I really appreciate you putting out this content brother, keep up the good work 👍🏻

    @dustenskinner8404@dustenskinner84048 ай бұрын
    • if it fits it ships, or if it works it twerks,,,best of luck to the next guy

      @J_ay_Z@J_ay_Z8 ай бұрын
  • Good job man ! Question ? How do you know which breaker is which circuit is going into the house or building. I missed that part. Thank you! Really appreciate it !

    @phillbenitez4216@phillbenitez42168 ай бұрын
  • excellent. pro. clean.

    @rondouglas6486@rondouglas64867 ай бұрын
  • If ground and neutral buses only take 10-12 awg how do you attach 6 awg ground and neutral? Great videos. Very clear explanations. Thank you.

    @DavidHagrid1@DavidHagrid17 ай бұрын
  • Great video! Why do you use a razor knife to strip your Romex , especially the larger three or four wire? Why not an electrician’s knife (foldable with the hooked blade) ? Also keep in mind that the has the required minimum wire-bending space in the cabinet gutter . Today cabinets have generous gutters compared to the panels in the past and by bundling current carrying conductors and the short bending radius that installers insist on doing in today’s panels create two issues 1) impeding heat dissipation 2) bends can exceed the maximum bending radius of conductors. Granted the panels look neat, but we can’t create bigger problems by not utilizing the gutters and gradually bending conductors and leaving some slack…sorry so long.

    @randypierce5887@randypierce58876 ай бұрын
  • only thing I'd change about your panel layout and would prefer to see on most. is leaving a 2 pole space open at the top for generator interlock kit, the proper side or better yet leave 2 pole empty spaces at both left and right, to also allow for future sub panel/high current device feed. I hate when sub panel feeds end up added to the bottom of the panel because everything is smashed full.

    @throttlebottle5906@throttlebottle59068 ай бұрын
    • Excellent forethought.

      @oskytel3780@oskytel37808 ай бұрын
    • yes, i always heard keep hottest breakers with most load at top and the surge protector.

      @ranger178@ranger1787 ай бұрын
    • @@ranger178 You may have heard that, but where the breakers are is irrelevant. Every part of the bus bar is rated for the same amperage.

      @pld8993@pld89934 ай бұрын
  • I'd love to see a video from you on how to properly fold wires into a regular receptacle/switch box. I'm very good with electrical work but that's still a skill I've never figured out.I wind up just smashing the wires in.

    @selmaave9145@selmaave91457 ай бұрын
  • This guy never wired a chicken house😂. Beautiful, detailed work.

    @thepitpatrol@thepitpatrol3 ай бұрын
  • Newest code requirements from the NFPA now says you can "not" bundle the conductors together as it will not allow heat to dissipate and could cause overheating. You would have to de-rate your conductors if you bundle them.

    @constructioninc@constructioninc8 ай бұрын
    • Not a new code requirement and there is no prohibition on bundling them together, but if you bundle/wrap conductors for more than 24" they must be derated

      @pld8993@pld89934 ай бұрын
KZhead