The BEST Way To Connect A Generator To Your House - Interlock Kit With Power Inlet Box Install

2022 ж. 20 Мам.
2 179 729 Рет қаралды

In this video I show you how I installed an interlock kit and 50 amp power inlet box so I can hookup my generator to my house and power it in the event of a power outage. How this is wired would be the same for a 30 amp power inlet box as well. Down here in the South it is not abnormal to get strong thunderstorms and hurricanes that can knock out power for extended periods of time. So it is important that I am able to keep my fridge and freezer on and nice to have our everyday amenities even without utility power. As always, if you don't feel comfortable
with electrical projects or don't know where to start, definitely reach out to your local electrician and they can take care of it for you. If you do decide to do it yourself, make sure to consult all local codes and have your installation inspected.
Tools and Materials Used In the Video:
Rophor 50 Amp Power Inlet Box: amzn.to/3ltTP7p
Interlock Kit In Video: Interlockkit.com
Southwire Lineman Pliers: amzn.to/3lwVN7i
Klein Multimeter: amzn.to/3lwHfEC
Klein Magnetic Screwdriver: amzn.to/3NmZHv6
Liquid-Tight 3/4" 90 degree elbow: amzn.to/3sNCFpk
Liquid-Tight 3/4 Straight Connector: amzn.to/3LE75RE
Liquid-Tight 3/4" NM Conduit: Best pricing at local home improvement store.
How To Run An AC With a Generator: • How To Install A Soft ...
Some of My Camera Gear:
Canon EOS M50: amzn.to/39GKiHu
GoPro Hero 9: amzn.to/3LEFGil
Tripod: amzn.to/39GKqGY
Rode On Camera Mic: amzn.to/39DSQis
DJI Drone: amzn.to/3wzj0fj
DJI Gimbal: amzn.to/38BvGJB
Thank you for watching and for subscribing. You can support the channel at no cost to you by using one of the above affiliate links. This helps support the channel for new content!
Blessings,
Adam
How To Home assumes no liability for damage or injury. How To Home highly recommends using proper safety procedures and professionals when needed. Our content is for entertainment purposes only. No information contained in this video shall create any express or implied warranty or guarantee of any particular result. Any injury, damage or loss that may result from improper use of these tools, equipment, or the information contained in this video is the sole responsibility of the user and not How To Home. How To Home will not be held liable for any negligent or accidental damage or injury resulting from equipment, tools, electrical, fire, electronics or any items contained in this video. Attempt projects and repairs at your own risk.

Пікірлер
  • Down here in the South we are starting to prepare for possible hurricanes. Do you have a backup power solution? If so, what are you using? 😎

    @HowToHomeDIY@HowToHomeDIY2 жыл бұрын
    • I like your American accent

      @pacearrow4620@pacearrow4620 Жыл бұрын
    • Being down South explains your main breaker on the outside of the house, but doesn't moisture and dampness cause corrosion specially w/ Hurricane weather. Most of our outages are in the winter, I'd rather not go outside w/ a foot of snow to hook up my generator.. My generator is in a shed attached to the back of my garage so I don't need to go outside. I open the shed door outside for ventilation...

      @rtoguidver3651@rtoguidver3651 Жыл бұрын
    • Spacecoast of FL here. Gonna have a certified electrician install one of these asap. Do not have the confidence to do this myself. Thanks for explaining what all will be done.

      @FC-cz6zd@FC-cz6zd Жыл бұрын
    • Same here, Louisiana.

      @kiddt1999@kiddt1999 Жыл бұрын
    • Purchased a Westinghouse 7500 looking forward to contacting an certified electrician to install a interlock/power inlet box asap

      @blakmosescctx@blakmosescctx Жыл бұрын
  • I had the same box and interlock switch installed by a professional electrician and as I recall it was about $170, but I supplied the inlet box and the interlock kit (about $70 for my panel). I have 5500 watt (6250 peak) inverter generator. It will run everything in the house except the AC (though it will run the blower so I have heat in the winter). Generator uses about 4 gallons of gas for 10 hours. I have had to use it a couple of times. My total investment, including the electrician, was about $1400. I am quite pleased with my investment. The power was out for three days during the great freeze in Texas last year and I swore I would never be without power in cold weather again.

    @shenmisheshou7002@shenmisheshou7002 Жыл бұрын
    • I live in Texas also and just had one installed. But in had to update my breaker box.

      @paulsosa1872@paulsosa1872 Жыл бұрын
    • @@paulsosa1872 @Shénmì Shèshǒu Wow! I just got hosed by an electrician that charged me $1200 to install that same $35 inlet box, the interlock kit, one 60amp breaker and 20 feet of 8/3. I got lazy and trusted them to install an actual transfer switch but he did this route instead and charged the same. I could not dream up how he charged $1200 for $200 in parts and 1 1/2 hours of labor. I need to become an electrician!!!

      @MARTiALYOU@MARTiALYOU Жыл бұрын
    • If you install a soft start, your generator may be able to run your ac

      @robertjohnsey9496@robertjohnsey9496 Жыл бұрын
    • I was quoted in the thousands for this work. $170? Please take my money!!! My electrician - handyman said it could go from a low of $1500 to $3000 and I don’t get the math. How do I request the job properly so I don’t get hosed? I’m in Miami and everyone is trynna get paid around here.

      @strokerace8458@strokerace8458 Жыл бұрын
    • @@strokerace8458 also in Miami, let me know how it goes

      @henryflores7492@henryflores7492 Жыл бұрын
  • Had a $15,000 quote for a whole house generator, $1,500 quote for a 10 circuit transfer panel, and put in an interlock, breaker, wiring, and generator inlet for about $150. Tested it out today and everything worked fine.

    @wes326@wes32611 ай бұрын
  • Great video I been wanting to do that same process you just explain and showed on your video. I’m out in California and we had one rolling black out. With the electric grid power shortage. I’m in the market for generator back power. You made it look so easy but I at least understand what it entails to install. Thank you and good job.

    @juanbanuelos3531@juanbanuelos3531 Жыл бұрын
  • This video as is today 4/18/24 it has more than two million views because it is a great information !😊

    @lindocielito32@lindocielito3225 күн бұрын
  • I’m an electrician but never did a generator like this. Mostly do commercial work. This all makes perfect sense. Awesome video.

    @sarahburke6884@sarahburke68844 ай бұрын
  • I used your past videos to install my backup generator and 4 ton a/c and everything is still working great thank you!

    @guavaball@guavaball Жыл бұрын
  • This is gold!! Direct and thorough coverage of the topic, no fluff. Thank you.

    @jasonhewell4600@jasonhewell4600 Жыл бұрын
  • Very thorough information. I did this same thing on my panel. Living in Colorado, losing power in the winter would be very dangerous. Really glad you put the interlock in place!

    @SeventhSamurai72@SeventhSamurai72 Жыл бұрын
  • Glad to see someone showing a safe,legal means of interfacing a generator as opposed to the drier plug,backffeed and other slug installs.

    @jamesellis5549@jamesellis5549 Жыл бұрын
  • Another excellent video. You keep it simple and concise with no unnecessary dialogue.

    @billvoss1362@billvoss1362 Жыл бұрын
    • I appreciate that! Glad you liked it. Thanks for the feedback!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • Excellent description of how to install it safely and THANK YOU VERY MUCH...look forward to other clear tips on your talents!

    @ReverendMarkJohnson@ReverendMarkJohnson Жыл бұрын
  • I am so glad to find your site. It is very helpful and you always make explain everything so clear and simple to follow. I always watch your videos first even before I start any electrical projects at home. Highly recommendable video tutorials . Thanks.

    @leopoldoagustin1222@leopoldoagustin1222 Жыл бұрын
  • Enjoyed the video. Years ago, I also installed a manual interlock kit on my Square D panel. The kit is basically the same with a nice template for drilling the panel deadfront for the interlock plate. I used a "3R" enclosure for my generator receptacle, in that, the twist lock plug plugs in the bottom of the box, making the connection waterproof. Works great. Thanks again!

    @4663David@4663David Жыл бұрын
    • I was considering just mounting my receptacle box directly to my main box allowing more water resistance 👍 I think it's a good idea.

      @kevinmaxwell6610@kevinmaxwell6610 Жыл бұрын
  • Im so glad professionals like you take the time to make these videos for the rest of us. Im a heavy equipment mechanic so not a complete newb but i have my profession and you have yours and share it Thanks.

    @dustyroads834@dustyroads834 Жыл бұрын
  • The power goes out here a lot during winter storms. I've always just run ext. cords from my generator to what ever I need to power up. It's time for me to evolve. Thanks for the informative, well produced video.

    @rodneysmart9774@rodneysmart9774 Жыл бұрын
  • Thanks for the notation about the neutral and ground being bonded on a main box. I was real sweating where to connect the white neutral wire!

    @JohnTurbeville-cy9uj@JohnTurbeville-cy9uj Жыл бұрын
  • Even as a Army electrician I still watch gold videos like this to see other peoples ideas and a refresher.

    @Crapse545@Crapse545 Жыл бұрын
  • I am a electrical contractor and this was a very good how to video. Don't forget your electrical permit. Where l live the power company will turn you in. Thanks

    @raymondcamp8212@raymondcamp8212 Жыл бұрын
    • Absolutely right about that. Thanks a lot for the feedback Raymond!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • Hey Adam, I've watched dozens of videos on how to connect my generator to my home breaker box, yours was by far the easiest to follow and understand. Thanks brother

    @NSAshchi@NSAshchi Жыл бұрын
  • The "Green light" is always welcome in all aspects of life. Keep up the excellent work and great content.

    @mackellyman5642@mackellyman56424 ай бұрын
  • This is definitely a much cheaper method of preventing back feed, but to be honest, I would still prefer a transfer switch, whether it be automatic or manual. But thank you for making this video.

    @gregorall9779@gregorall9779 Жыл бұрын
  • Well done Adam. Concise and very detailed. To me this is definitely the way to go.

    @johnpicard4909@johnpicard49092 жыл бұрын
    • Glad you liked it. Thanks a lot for the feedback John!

      @HowToHomeDIY@HowToHomeDIY2 жыл бұрын
  • That was a great video. I know nothing about this but want to install one in our new home and this video explained it wonderfully. I like that you showed and explained EVERY detail of what you were doing, very helpful indeed. Thank you again, this was a great help.

    @hummingwind8869@hummingwind8869 Жыл бұрын
  • Wow you’re very talented at explaining and showing each step. Thanks for the great video

    @BenjaMin-ju4ji@BenjaMin-ju4ji Жыл бұрын
  • Dude, I was "shocked" to see how easy you made this look. I got a real "charge" out of the video but I will still hire a seasoned PRO such as yourself to do my install. Thanks man you have helped thousands!!😎

    @johnnyo5915@johnnyo59152 ай бұрын
    • 😂 I like what you did there! Well I’m really glad to hear it “sparked” your interest! Nothing wrong with having a pro install it at all. Thanks a lot for the feedback!

      @HowToHomeDIY@HowToHomeDIY2 ай бұрын
  • Your video just might be the BEST instructional video I have ever watched! Thank you for your attention to detail sir!

    @randykish8242@randykish8242 Жыл бұрын
  • Great video, man. I am doing the same for my house, using a 30 amp inlet / breaker set up. I appreciate you sharing this content.

    @the_grand_chawhee@the_grand_chawhee Жыл бұрын
    • How did the project go then?

      @kevingarner7107@kevingarner710710 ай бұрын
  • Excellent tutorial. I'm doing this soon because it pays to be prepared. Thank you

    @williamfotiou7577@williamfotiou7577 Жыл бұрын
  • Excellent Video. This is the Same setup I used in our home. It's low cost, compared to Transfer Panels, way easier to wire, and works safely, preventing power back feed to the utility.

    @jameslester4474@jameslester4474 Жыл бұрын
    • If you have the intelligence and skill to do this aren't you capable of switching the main breaker off " preventing power back feed to the utility" ?

      @bigpardner@bigpardner Жыл бұрын
    • @@bigpardner Who is going to guarantee that you will be the only one to do the power up?

      @rf8driver@rf8driver Жыл бұрын
    • This is a safety security concern as to why there exist a inter lock. Screw ups are prevented with this device. To each their own. @@bigpardner

      @metrork1@metrork14 ай бұрын
  • Great Video ! I'm a retired electrician and your information is spot on and concise , excellent instructional video.

    @akyak333@akyak33310 ай бұрын
  • Electrical work always looks a bit intimidating for me. You make it very nice and simple here in this video. It is a nice set up. Thank you.

    @carle5538@carle5538 Жыл бұрын
  • Great information, im doing the install this weekend and your video was perfect, I have the same parts . thanks for the info.

    @jeffreyscott8174@jeffreyscott8174 Жыл бұрын
  • Good job Adam and nicely explained! We have virtually identical setups. I have a MicroAir Soft Start on my 6T AC and a 9500w Westinghouse generator dual fuel running into my 50a inlet box. Works perfectly!

    @gottofly2@gottofly22 жыл бұрын
    • Hey Lenny, yes I think I recall many months ago talking to you about the soft start kit. I think you were waiting on more to come in. It makes a massive difference doesn't it? Really glad to hear you are all setup. Thanks a lot for the feedback.

      @HowToHomeDIY@HowToHomeDIY2 жыл бұрын
    • What does the soft start kit do and how do I know if I need one? I have a 9500 running 12000 peak generator that I just set up for 50 amps exactly like your video shows.

      @feelthepayne88@feelthepayne88 Жыл бұрын
  • As part of my research regarding connecting a portable generator to my home, I have viewed many, many, video tutorials, some of them good, and many of them not so good. I would have to rate your video presentation as the best that I have seen. Your explanation is clear, your instructions are accurate, and you include a video list of all the items needed. You present a good balance between text and visuals. You should consider training KZheadrs on the art of KZhead presentations. Well Done, Sir!!

    @septimuspretorius250@septimuspretorius250 Жыл бұрын
  • Someone that doesn’t know anything about electricity can easily instal this with the way you explain it 👏🏽👍🏽 best explanation I’ve seen I’m a visual learner, some people leave things out

    @1313velasquez@1313velasquez Жыл бұрын
  • Thsnk you sir this was the best installation video I've seen yet straight to business with no extra jibber jabber. I will be connecting my Genny to the house next month thanks to you.

    @universallaw8850@universallaw8850 Жыл бұрын
  • This video really changed my mind when it comes to choosing between an interlock switch or the transfer switch. Since I have a bigger generator, I'll go with an interlock switch setup. Thanks a lot.

    @jafarym77@jafarym7710 ай бұрын
    • the INTERLOCK simplified it all and I’m all smiles knowing that food and peace of mind will be intact during future outages

      @theMister07@theMister079 ай бұрын
  • I do all the remodel and repairs on my properties myself. But I NEVER felt confortable doing electrical work. Thanks to you I have ventured for the first time installing 6 outlets, 2 light switches of a GFI outlet, and now I might even do this installation. I live in Florida and hurricanes are coming. Thank you of keeping it simple and clear. I really appreciate what you do.

    @carlmergenthaler5151@carlmergenthaler5151 Жыл бұрын
    • Did you get your generator?

      @timjustice5046@timjustice5046 Жыл бұрын
    • Hopefully you followed through without hesitation.

      @johnlockesghost5592@johnlockesghost5592 Жыл бұрын
    • Carl, I am an electrical guy not a tax preparer, so I recommend this for your consideration. If your properties are a business, I believe repairs are tax deductible. Use a reputable electrical contractor to do some of the work and you work with them like a trainee. This will get you safety, skills, and knowledge, but most importantly the satisfaction that you did some of it. The big bonus is that you have some you know just a phone call away. Your local guys should know all the local rules. The rules are not hard to find, but the experience might be. Example:. Bathroom receptacles must be GFCI protected and one breaker can cover everything in a bathroom, but wiring it up to prevent a GFCI trip to not turn out the light might be a problem for some. Along the same lines, GFCI protection can be provided by a receptacle or a breaker. Your naked wife with wet hair may not want to run from the second floor to the basement to reset the GFCI. I hope you can easily shift into electrical doings. Be safe and good luck.

      @keithharrington4595@keithharrington4595 Жыл бұрын
    • FYI...It's illegal for a home owner to do electrical work, plumbing, or gas work in anything other than a Single family home. A multi family must be done by a licensed contractor.

      @deanmiles3505@deanmiles3505 Жыл бұрын
  • DAMN! You just saved my husband and myself a helluva lot of money. I just shared this with my girlfriend down in Texas and she and her husband have rental properties there. They were looking at permanent generators for their properties and this makes it so much more affordable just in case you go down. I have another girlfriend in Ohio I'm sharing this with as she's had issues with her electricity going down too. I'm sitting in a Starbucks watching this being without power for over 14 hours right now.

    @amiedavis5257@amiedavis525710 ай бұрын
  • Best of over a dozen Videos on Generator Connecting I have watched 🎉

    @marklinn1000@marklinn10003 ай бұрын
  • fantastic instructions, clear and to the point. thanks

    @claudeesteves1234@claudeesteves1234 Жыл бұрын
  • This is a great video! A lot of videos show installation in subpanel, love that you are doing it for main👍

    @xvolkodavx446@xvolkodavx446 Жыл бұрын
  • Thanks this is helpful, especially to see how inexpensive it really is to have a safe hook up

    @myleschater6922@myleschater6922 Жыл бұрын
  • Perfect DIY project and video. If your locale requires you to pull a permit, I suggest getting one. The inspector will check your work and sign off on your permit. Some, if not most, insurance companies would not honor a claim concerning this installation if you didn't pull that permit and have your work inspected. It's in their policy fine print.

    @outlet6989@outlet6989 Жыл бұрын
  • Dude, brilliant. I had watched other videos on how to install a manual transfer switch, but this is much cleaner and perfect for our needs. We bought a DuroMax XP9000iH with a running wattage of 7600. It won't power our entire house, but we'll play with the circuit breakers that we'll need and cycle the ones with big draws. Will be getting that soft start kit for the AC as well. Thanks a ton!

    @CubanRider@CubanRider Жыл бұрын
    • Sounds like a plan! Glad to hear it sounds like you are getting all set. Thanks for the feedback!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
    • Interlock kits are a "gray" way to meet code for feeding alternative power source to your home. They are not best practice, and they also can make it hard to balance the load on the two 120 legs of your generator. For example my breaker box has all but one breaker that I need in an outage situation on the left 120 Busbar (left side of breaker box) if I used the method from this video almost all my load would be on 1 120 leg of my generator. A manual transfer switch solves for this, and is best practice for backup power.

      @jov415@jov41510 ай бұрын
    • @@jov415 Thank you for that commentary. I was leaning toward a transfer switch but the interlock kit/method looked a little more straight forward. I know it's less expensive, which is some benefit but not my whole reasoning. I am now rethinking back to a transfer switch as the interlock seems a bit less safe. That being said, I am on Consumers Energy (company) in west Michigan and they *kind of* mention interlock by way of saying something like having something to prevent accidentally back-feeding the grid. That all being said, a transfer switch looks a lot more safe.

      @svenska572@svenska5724 ай бұрын
    • @svenska572 there is nothing "wrong" with an interlock device as it meets the spirit of the code, which is protecting linemen by prohibiting generator power from reaching the grid. Saying that, it mounts on a removable breaker panel and, therefore, not a 100% foolproof method. Saying that, as long as you, the homeowner, are aware of this, they are fine. Now, the other issue is balancing load on the 2 legs on a generator. An 8000W generator isn't designed to have all 8000W ( or most of it) pulled from one leg of the generator and could damage the windings. This all depends on your breaker layout and/or the circuits you want supported by generator power. You want to look at your panel and calculate an estimated load for each circuit and each 120 leg. If you find it is very unbalanced, a transfer switch can help you solve for this. The one that I utilized has some documentation that includes a sample chart with power estimates to help with load calculations. www.reliancecontrols.com/products/reliance-controls-pro-tran-transfer-switch-125-250v-30a-nema-l14-30-10-circuits-metal-gray-r310a

      @jov415@jov4154 ай бұрын
  • Thanks so much for this video, as today I just finished my own generator project. I had to reorder the correct interlock kit for my panel, but when I finally got everything installed it felt great. It’s good to have peace of mind knowing you have a back up power source if the grid goes down.

    @gelguitarist@gelguitarist3 ай бұрын
  • I just completed the same generator interlock and interface box. It's as easy as you described.

    @joeolejar@joeolejar9 ай бұрын
  • I'm a designer for a Generac dealer in the south and your video was very helpful and informative. Thank you!

    @jaredporche1592@jaredporche1592 Жыл бұрын
    • You are welcome. Glad you liked it. Thanks a lot for the feedback Jared!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • If you're reading through the comments as I did,there is one extremely important thing left out in this video. You MUST have an unbonded generator to SAFELY connect it to your house.There are tons of videos on how to do this.There can be ONLY one location throughout your electrical system that the neutral and ground are bonded and thats at your main disconnect. Make sure you understand and do this before connecting a generator to yout home.I learned the hard way and fried a huge portion of electronics in my home because I failed to unbond my generator.Lesson learned and thought I would pass this along.

    @catfish500mark9@catfish500mark92 ай бұрын
    • I have a bonded generator that I plan on making a unbounded neutral. Once that is done will the method shown in this video be the correct way to wire the unbounded neutral to my home

      @martinberlanga4914@martinberlanga491410 күн бұрын
    • @@martinberlanga4914 yes sir. I simply used an ordinary house light switch that way you can choose between bonded or unbonded and your generator will easily be switched from one to the other.All the best.

      @catfish500mark9@catfish500mark910 күн бұрын
    • Does the 50 amp breaker at the house, have to be on before turning on the power plant breaker.

      @GB-it2qh@GB-it2qh8 күн бұрын
  • Excellent video and information thank you 🙏 I’m just now shopping for a generator and trying to learn the best way to connect it to the house.

    @Cad1900@Cad19002 ай бұрын
  • Great video. This is how I have my house wired with 30amps. I will upgrade to 50 eventually. I upgraded the generator a few years ago to from a Generac 6.5k to a DuroMax 13k gasoline driven. I plan on upgrading the house to 50 amps in the next year and adding propane fuel to make it a dual fuel (if possible). With the cost of everything going up it may take a little longer. Covid19 nearly killed me so I'm going to reposition the generator connection to the front of the garage. Makes it much easier for me to deploy the generator while I'm on Portable oxygen. I can pull the generator out of the garage much easier than trying to pull it around the house. I was so impressed with the DuroMax generator I became an authorized service center for them. I have never had a "no start" situation.

    @Truckinman2000@Truckinman2000 Жыл бұрын
  • Great video. Very clear and easy to understand for anyone. You might want to have let.people who have no idea what they are doing that the conductors feeding the top of the main breaker are still hot despite being shut off. Some people attempting this install may not be aware and if there was too much insulation stripped back on those conductors they could be exposed and be a shock hazard especially when feeding new conductors into the panel.

    @bryanbutler4067@bryanbutler4067 Жыл бұрын
    • If they have no idea what they are doing, then they are *NOT* doing this. Hire an electrician

      @MrSummitville@MrSummitville Жыл бұрын
  • really liked the straight forward approach and step by step instructions. Thank you!!!

    @mikepintell2267@mikepintell2267 Жыл бұрын
  • Nice description and example. I need to do this to my house but have the electric panel inside the house in a wall. So I will require longer feeder lines to reach an outside wall. Thanks very much for the detail on this. 👍

    @fatherguidosarduchi5204@fatherguidosarduchi52043 ай бұрын
  • Great video. I found an interlock for my Square D panel for 30 bucks! Lots of room too. I have a 4500W (120V only) but it runs everything I need for winter outages since I have a Blaze King wood stove and I can run my water heater at 120V, it just takes longer to heat. And I got all my freezers and refrigerators running fine which is the biggest deal. Anyway thanks again I kinda just confirmed what I thought.

    @beentheredonethatoriginals5673@beentheredonethatoriginals5673 Жыл бұрын
    • Can you tell me how you made the adjustment to 120 volt on your electric water heater? I'm not being smart I just want to know so I can go smaller on my generator.

      @joejackson73@joejackson73 Жыл бұрын
  • Excellent video and easy to understand installation instructions. Keep up the good work!

    @raulcorniersr.6715@raulcorniersr.6715 Жыл бұрын
  • Good video! I got the same inlet box; yes, knockouts are fake and I do love the silly green light!! We lost power for 10 hours recently and all worked perfectly; thx for your video!

    @robertmunroe3976@robertmunroe3976 Жыл бұрын
  • Great job on this video. Precise , accurate, and superfluous words. Very helpful. Thank you.

    @Rochesterhome@Rochesterhome Жыл бұрын
    • Glad it was helpful! Thanks for the feedback!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • I fought buying a generator here in SW Florida since I moved here in 1997. After Ian that was it! I educated myself, bought a nice high end Westinghouse WGen9500 Dual Fuel generator and had a personal friend, who's an electrician install my 50 amp box & interlock kit *OFF THE BOOKS* I am ALL set for the next hurricane. Great vid though

    @USMCSDI@USMCSDI8 ай бұрын
  • Great Instructions! Thumbs up on this one. I set up a 30 amp interlock system for my house. Using a 55 watt 8250 watt surge gen. Only thing I can't run is the Central Air. I went one step further and converted my gen to use natural gas so I don't have to worry about gasoline storage problems. Thanks for the Vid! :)

    @xcalibre222@xcalibre222 Жыл бұрын
    • I have a similar set up but with a propane conversion. Look into getting a soft start kit for the central air. It ramps up the amperage to allow the generator to handle the load.

      @NealWinters@NealWinters Жыл бұрын
    • I got a 12000 watt DUROMAX but am going to be installing a 30 amp switch like you. Though the DUROMAX can handle 50 amps, the cost is double and I don't plan on ever running this beast beyond 50% load. Do you have any info or are you able to point me in the right direction or as to how I can go about converting mine to natural gas also by my chance? Any help would be much appreciated

      @nikolasvel@nikolasvel Жыл бұрын
    • @@nikolasvel One caution: If using a power cable less than 50A rated be sure to use the generator's 30A receptacle, not the 50A one, & be sure anyone else using the unit knows - and remembers - that. Fuses and circuit breakers exist to protect wire and the 50A outlet from the generator would not safely protect a 30A (#10/3) cable.

      @larrydouglas3951@larrydouglas3951 Жыл бұрын
    • @@larrydouglas3951 thank you for the response. I ended up going with a 50 amp cable, 50 amp recipticle, 6/3 copper wire to a 50 amp breaker and an interlock kit. I also added a "reliance power back on" detection device.

      @nikolasvel@nikolasvel Жыл бұрын
  • They now have rubber grommets in place of the knockouts on the inlet box. They must have listened to you. Thanks for the video.Getting mine hooked up now!

    @ryanpebbles1731@ryanpebbles17318 ай бұрын
  • Great video, that has to be one of the best tutorials I've ever seen! You my man are very thorough! Nice and easy to follow simple steps. Great job, ty

    @-MrRichBiker1967@-MrRichBiker19677 ай бұрын
  • Followed step by step works beautifully. Would have never attempted without your guidance.

    @rebelsixtynine1@rebelsixtynine1 Жыл бұрын
    • Excellent! Really glad to hear it was helpful and you are all set! Thanks for the feedback!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • Hello Sir, love your videos. Very informative and very easy to follow. I have a situation though. I'm trying to set up an Ecoflow system in my garage, and in all the videos I have reviewed, the Main is typically incorporated in the same electrical box. However, my Main cutoff is on an outside panel and the inside box is on the opposite side of the house. How would I go about installing the 30 amp plug in the garage and the interlock switch since it doesn't look like have a Main inside? Would I have to install another Main on the garage electrical box? Thanks for your time.

    @user-dq1uw7um3o@user-dq1uw7um3o10 ай бұрын
  • Hurricane Ian here so browsing installations and feel like I can install it all myself. Good job 👍🏼

    @chrispereira2997@chrispereira2997 Жыл бұрын
    • I am also in Ian. Glad to hear you liked it. Thanks a lot for the feedback and stay safe!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
    • @@HowToHomeDIY you as well!

      @chrispereira2997@chrispereira2997 Жыл бұрын
  • Thanks for your very detailed info- clip which may enable me to finally install a box for the 9K generator - take care & try to stay out of trouble!

    @johnlong7504@johnlong750410 ай бұрын
  • You noted different wiring for bonded vs. floating neutral. Was the wiring you did for a bonded neutral generator, or for floating? And what are the differences in wiring between the two when installing the outlet that the generator plugs into?

    @Samsquanch96@Samsquanch969 ай бұрын
  • Great video. I have done about 4 of these installs (30A), the process is the same, the plug & wire sizes are different. The interlock kit is essential - this will prevent you from back feeding the power lines & not injuring the guys trying to fix the power.

    @jeffryan590@jeffryan590 Жыл бұрын
    • all of the codes for proper solar systems require a electro-mechanical disconnect that automatically disconnects the grid from your home in the event of a power failure. It must be manually reset and can only be done so once the grid is going again. Both the City/County inspectors along with the energy department's inspectors must sign off on it to get your system approved. If a buy back of over produced power is approved, then a contract and bidirectional meter is installed. There's nothing like a lineman getting zapped by someone. I've seen the mechanical ones and they're fine, however for those on hospice care and CPAC machines, keeping the power going automatically after the power goes out is nice.

      @keithlucas6260@keithlucas6260 Жыл бұрын
    • @Keith Lucas, can you advise where I can find an electro-mechanical disconnect and what they look like? Thanks

      @carlosmerino121@carlosmerino121 Жыл бұрын
    • What size wire for 30amp plug?

      @juanrdgzg@juanrdgzg10 ай бұрын
    • @@juanrdgzg10/3 Romex with Ground

      @theMister07@theMister079 ай бұрын
    • Seems like it’s always better to install a 50A generator inlet and just use an adapter for the cable so if you do upgrade you don’t have to replace it.

      @np4057@np40573 ай бұрын
  • I install my own inspired by this video plus I’m motivated by my self on repairing my own stuff !

    @lindocielito32@lindocielito3225 күн бұрын
  • Well done once again. I had a 8500 running watt genny II connected through an interlock kit on my main panel. I worked flawlessly, powering everything except the 3 ton ac. Tankless hot water and furnace are natural gas. Last year I caved and had a whole house 24k ng unit installed by a contractor I use a lot for rentals and our house. $12,800 total cost. We also added the Micro-Air Soft Start to the ac unit.

    @utubetjc@utubetjc3 ай бұрын
  • Purchased this kzhead.infoUgkxOTeIs0vv4_9B5hsmnLsk9r930uDQLu_Y after researching several brands.Reasons for picking this one was, dual fuel, I don't have to carry gasoline and stink up my truck bed!Propane is so much cleaner.Quiet 62 db, won't piss off neighboring campers!Less than 100 lbs, can lift in to truck bed.I can run my 30 foot Transcend 261BH, AC among other appliances.

    @SuperResa14@SuperResa149 ай бұрын
  • Great informational video! You should also ground your generator. I used an automotive battery cable and a screw clamp to the ground rod near my box. If you only have a 30A generator, select wiring and a tie-in plug rated for 50A. Be sure to use a 30A breaker in the interlock. When you get that bigger generator, then you can swap out the 30A breaker, and will not need to rewire or replace anything else.

    @robertfielding1723@robertfielding1723 Жыл бұрын
    • If you plug a 30 into the 50 amp plug the generator already has breakers for the output, in that case the panel breaker only serves as a disconnect. So it doesn't matter.

      @roberthughes2687@roberthughes2687 Жыл бұрын
    • Generators these days are already grounded... Some states dont require additional grounding.. However check your codes..Yours might

      @tray8411@tray8411 Жыл бұрын
  • Check your specifications in your town ore City because some of them you have to have electrician's license to hook anything up like this but I really really do like this video he has really showed a lot of us a lot of things I really appreciate this video

    @rickydraughn3965@rickydraughn3965Ай бұрын
  • flawless video, ultra professional and great work, you know your craft!

    @pildorasamargas2271@pildorasamargas2271 Жыл бұрын
  • I have about the same setup but went with a GE T050N inlet box. Plenty of room for conductors, real knockouts, and the angled receptacle takes strain off the cable and plug. Not as weather tight as the box you used, but being mounted in an exterior storage closet means weather isn't an issue. Real UL listed, too, not "claimed to be but really isn't" like a fair bit of stuff out there. Unfortunately it appears to have gone up significantly in price.

    @smilingeyes1938@smilingeyes1938 Жыл бұрын
  • One thing you should have mentioned is that loads should be staged on one breaker at a time to reduce the surge. Another is always disconnect loads before turning off the genset. As the generator winds down the voltage and frequency drops which can cause failures of equipment and the generator itself. Voltage and amperage are inversely proportional, as voltage drops amps go up and can burn out electronics

    @ronblah8538@ronblah8538 Жыл бұрын
    • @a mere bondservant Yes, that is always the best way. Unless you have a larger generator and ATS

      @ronblah8538@ronblah8538 Жыл бұрын
  • I had wanted to add a generator to my house. Thank you for demonstration.

    @tomunverzagt5271@tomunverzagt5271 Жыл бұрын
  • FirstSurge...we will be installing one of those on our off grid solar system. Thanks for the video!

    @rongray4118@rongray41184 ай бұрын
  • I suggest those who may not be planning to stay in their current home for too long look into the Generlink interface. It mounts between your meter and the meter socket and is UL listed. With this you plug in a single cord form your generator to the Generlink and when you do the whole house is automatically disconnected from the grid so you can't backfeed out onto the grid. You can also power any device in your home up to the capacity of your generator and the version of the Generlink you install. I have been using mine for 8 years and it is 30A. I can run my well pump, the boiler, plus some lights and essential equipment like the freezer and fridge. You don't need to install any sort of interface box, don't need an electrician or a permit and inspection. The utility installed mine for free. Best part is if/when we decide to move I can unplug it and take it with me. I don't have to leave my investment behind. The Generlink also has a whole house surge suppressor that is active all the time, not just when running off the generator.

    @bobd.@bobd. Жыл бұрын
    • Hi Bob thanks for the info. About what does this cost?

      @brentsharon404@brentsharon404 Жыл бұрын
    • They cost about $600-1 $1000 depending on model. They WILL NOT work with the new “smart meters” that are being installed across the Country. Best bet is to do what this video says and have an interlock system installed and be done with it

      @clarkallen4541@clarkallen4541 Жыл бұрын
    • @@clarkallen4541 those "new" smart meters have been around since 1975

      @firecrow7973@firecrow7973 Жыл бұрын
    • It's not allowed by a lot of utility providers. My provider will not install one

      @projectswithjw@projectswithjw Жыл бұрын
    • Ummmm I have seen and heard many people saying that their utility's company's won't allow them to be installed.. either way if someone should move that has installed an interlock system like in this video , they could uninstall it and take it to their new house just as easily.. but in their own .. without the need of the utility company to come and uninstall it for them ..

      @DOCDOCFLAMINGOS@DOCDOCFLAMINGOS4 ай бұрын
  • Great video and love the content! I assume the 50 amp breaker does not need to be GFCI breaker?

    @smithgae@smithgae Жыл бұрын
    • Really glad to hear you liked it! Just a regular double pole breaker. Thanks for the feedback!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
    • @@HowToHomeDIY You cannot use a GFCI breaker because they are not designed to be backfeed. Almost all GFCI breakers are labeled not to backfeed.

      @alexfriedeck1978@alexfriedeck1978 Жыл бұрын
  • I just completed an inlet box like this build thread. Works perfectly! You might mention that you need to infact have a 240V generator to power up both sides on the panel with a double breaker.

    @ToddSails@ToddSails2 ай бұрын
  • Very helpful. Excellent in explaining and teaching. Thanks a lot!

    @LYHONGTHAIHONGGIA@LYHONGTHAIHONGGIA Жыл бұрын
  • Nice, informative video. I currently have a 30 amp generator, but want to install a 50 amp power inlet box for a future generator upgrade. Would there be a issue using an "RV 30 amp to 50 amp adapter" to connect the generator to the house until my generator upgrade?

    @sgribb@sgribb Жыл бұрын
    • I can't think of a reason why that would be a problem.

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • Hi Adam, down here in Florida. For someone that is not to comfortable with electric projects you do a great job explaining how everything works and parts required. We should have our Westinghouse 9500DFc/12500 dual fuel come in this week. I am trying to find someone to hook everything up. Concerning the plug I was thinking a bottom facing plug on the inlet box weatherwise would be a better option. just wanted to know your thoughts on this. Thanks, Paul

    @paulszo@paulszo Жыл бұрын
    • Hey Paul, totally understand wanting to get someone to install it. Can’t go wrong there. Just make sure to get a few quotes. My old inlet box faced the ground. That’s why I bought it as well for resistance to the weather. It worked great. My only complaint was when trying to connect the plug to it, it was darn near impossible to see in order to line everything up. Aside from that, no complaints! Thanks a lot for the feedback!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
    • In Florida FPL will install the best solution. They remove the meter and replace it with an interconnect you plug directly into at the meter. It will automatically switch back to the grid when power is restored. Its not cheap but neither is frying a lineman because someone installed an interlock incorrectly.

      @andyd9900@andyd9900 Жыл бұрын
    • I’ve seen that. It’s interesting.

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • Absolutely outstanding video. Thorough and concise and easy to understand.

    @dwdale68@dwdale68 Жыл бұрын
    • Glad you liked it. Thanks for the feedback!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • Your video was not just helpful, but it was awesome. Two thumbs up.

    @greenlegaciesrobertlaurist8737@greenlegaciesrobertlaurist8737 Жыл бұрын
  • thank you for a basic wiring videos, like how to run an extra wall switch and plug. I'm restoring a bedroom and changing out some old wiring. We put in two new plug in outlets.

    @msdespain@msdespain Жыл бұрын
  • just be careful and use a torque screwdriver to make sure its within specs

    @jonlee5642@jonlee5642 Жыл бұрын
    • Great advice with torquing to spec. Also, 6" of wire from the face of the box would be nice and perhaps strap your conduit with a one hole strap.

      @richardrichard8741@richardrichard8741 Жыл бұрын
  • Great video. All the information I needed in a simple, practical way to do it. Thank you so much !!

    @fredbentley4944@fredbentley4944 Жыл бұрын
    • Awesome. Really glad you liked it. Thanks a lot for all of the feedback Fred!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • Be careful everyone!!!!! This installation might not be right for you. You need to verify your generator does not have a bonded neutral if you are using this wiring method. If your generator has a bonded neutral you need to have a 3 pole transfer switch that isolates the generator neutral(white wire) from the power company’s neutral. VERY IMPORTANT!!!!

    @jmommy991@jmommy991 Жыл бұрын
    • So we could just make the neutral bonded generator a floating neutral and this method would be fine?

      @degen_dad7682@degen_dad76828 ай бұрын
    • @@degen_dad7682 you could if you have the ability to do so. Some generators mainly inverter generators can be difficult to switch around from bonded to floating and vice versa.

      @jmommy991@jmommy9917 ай бұрын
    • @@jmommy991 So once you convert to floating neutral will this method of wiring be the correct way?

      @martinberlanga4914@martinberlanga491410 күн бұрын
  • Let’s go brandon 🍦🍦🍦

    @richardtuholsky4028@richardtuholsky4028 Жыл бұрын
  • This guy is awesome for Diy homeowners.

    @alexanderviolinist@alexanderviolinist Жыл бұрын
  • Our circuit breakers are all inside 200 amp, in our basement, love to get a generator, neighbors uses one with several extension cords 😊, that’s our gutter, thanks for posting informative

    @teaglet1@teaglet1 Жыл бұрын
  • Just did it with my Firman generator, works great, beats running extention cords

    @tombo552001@tombo5520017 ай бұрын
  • Really nicely done. Straightforward explanation.

    @adriansanchez5045@adriansanchez5045 Жыл бұрын
  • Your level of detail is amazing. love this vid. subscribed

    @jacobpeters5458@jacobpeters54588 ай бұрын
  • Very nice explanation without a bunch of opinions and or nonsense.

    @davidhoover8877@davidhoover8877 Жыл бұрын
  • you have the best videos regarding generators, thanks for educating us rookies

    @y2k704@y2k704 Жыл бұрын
    • Really glad to hear you liked them! I really appreciate the feedback! Thanks a lot!

      @HowToHomeDIY@HowToHomeDIY Жыл бұрын
  • Nice, I’m going to get it done because of your great instructions ✅😎❤️

    @arboristo4407@arboristo4407 Жыл бұрын
KZhead