Electrical Installation Condition Report Sample - Part 4

2020 ж. 2 Мау.
25 195 Рет қаралды

Electrical Installation Condition Report Sample - Part 4
In this final part I carry out earth loop impedance testing and discuss my conclusions with you.
👀 Watch More Videos
Watch Part 1 Here: • Electrical Installatio...
Watch Part 2 Here: • Electrical Installatio...
Watch Part 3 Here: • Electrical Installatio...
The following ADVERTS help our channel to survive:
TRADIFY:
If you're looking to get more organised with your work Tradify provide great job management software. It's super easy to use.
I've been using it for a few months now and it has helped me a lot!
Check it out here: bit.ly/3g4Li7d
🧰🛠️ Tool Of The Day 👇
Knipex Twinkey Set: amzn.to/2LVkpVh
Kewtech Kewprove Kit: amzn.to/36ajlWU
Kewtech Voltage Tester: amzn.to/2WLJjNw
Fluke 1664FC: amzn.to/3g6tyID
Long Wander Lead: amzn.to/2LH4Y37
🏷️ DISCOUNT BUSINESS SUPPLIES 👇
➤ www.amazon.co.uk/tryAB/?tag=a...
-----TRADES INSURANCE DISCOUNT-----
If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, i've just renewed my insurance with them.
🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
➤ www.rhinotradeinsurance.com/quote
📞 or call 01162437904.
CAUTION: Never work on live electrical installations. If in doubt always seek the advice of a qualified electrician. This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
✅ Check Out All Our Favourite Tools Here 👇
➤ www.amazon.co.uk/shop/artisan...
🔔 Subscribe to TOOLS4SPARKS KZhead Channel 👇
I Also Have A Dedicated KZhead Channel About Tools:
➤ / tools4sparks
-----TESLA REFERRAL CODE-----
🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
➤ ts.la/andrew24855
MY ENERGY PROVIDER:
Bulb - Use this referral link and we will both receive £50! www.bulb.me/andrew8530
DRIVE ELECTRIC:
If you're thinking of getting an electric car and going with leasing, contact Francesca at Drive Electric, if you tell her you came from Artisan Electrics she will look after you.
www.drive-electric.co.uk or email: francesca.decozar@drive-electric.co.uk
Use my referral code if you get a Tesla: andrew24855
✅ CHECKATRADE:
Get a £50 voucher when you join Checkatrade quoting our Member ID: 505219
join.checkatrade.com/friend
FREE STOCK SHARE worth up to £⁠100:
Create a Trading 212 Invest account using this link www.trading212.com/invite/FAtr and we both get a free share!
AMAZON DEALS:
Amazon Prime FREE for 30 Days:
www.amazon.co.uk/tryprimefree?...
FREE 30 day Membership to Amazon Prime Video is available here:
www.amazon.co.uk/gp/video/prim...
FREE Amazon Music UNLIMITED for 30 days here:
www.amazon.co.uk/gp/dmusic/pro...
FREE 30 Days Audible subscription here:
www.amazon.co.uk/Audible-Membe...
📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
📸 Artisan Electrics Instagram Account 👇
➤ / artisanelectrics
🐦 Artisan Electrics Twitter Account 👇
➤ / artelectrics
📓 Artisan Electrics Facebook Account 👇
➤ / artisanelectrics
This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
#ElectricianLife #ElectricalTesting #ArtisanElectrics

Пікірлер
  • Appendix B Table B6 . Maximum zs for Type B 6 amp 60898 MCB is 5.87 ohms. Thanks for putting this content on youtube, it is good that there is advice and guidance available within the industry & at the same time showing possible customers a good view of what to expect if they use your service.

    @mikedavis2341@mikedavis23413 жыл бұрын
  • Thank you, your content helps tremendously. The use of Fluke another reason I follow.. I would like to see how auto test will do onsite.

    @skyfsa@skyfsa3 жыл бұрын
  • Grand champ once again bro! Please do another! Absolutely; love the vids. 👍🏾

    @linksone6287@linksone62873 жыл бұрын
  • @Artisan Electrics - BS60898 Type B 6amp maximum earth fault loop impedance is 5.87ohms

    @titmando1199@titmando11993 жыл бұрын
  • Hi Jordan. Nice run through on the EICR not sure landlords will do it every time they put a new tenant in as I know some that have about 3 in a 5 year period.

    @stuartbrown2567@stuartbrown25673 жыл бұрын
  • Thanks for sharing 👍

    @RWATraineeElectrician@RWATraineeElectrician3 жыл бұрын
  • Hi jordan, love watching the informative content you guys produce at Artisan. I was wondering if you were to purchase a new MFT which would you go for ? Megger MFT1741+ or Fluke 1664FC ? As you have experienced using both machines which do you prefer ? Cheers 🤔

    @danielwood5334@danielwood53342 жыл бұрын
  • Great video jordan 👍 love the content at the minute as I am a adult learner , keep up the good work

    @jordangallacher276@jordangallacher2763 жыл бұрын
  • Hi Jordan, enjoying the content, keep up the good work! This isn't criticism but simply an observation regarding your testing methods. Feel free to correct me if I'm wrong but it is my understanding that Zs cannot be used to prove polarity. Polarity is a dead test (other than incoming supply) and thus should be confirmed visually or with the use of an R1 + R2 test. I prefer to use the R1 + R2 test method for the continuity of CPC as it satisfies both the continuity of CPC and polarity checks. Furthermore the R1 + R2 test also facilities the calculation of Zs and in some circumstances this is safer than carrying out the live Zs test by measurement. Where safe to do so I also carry out the Zs test by measurement and compare it against calculated results.

    @ruhulali8129@ruhulali81293 жыл бұрын
  • Great vid keep them coming like the eicr vids how long did the appartement take

    @leeburnside735@leeburnside7353 жыл бұрын
  • I'm supprised test equipment manufacturers haven't developed their own form software that wirelessly links to the tester and fills in the form as you go along depending on the readings you are taking. Could be one hell of a time saver, especially if the UI in the tester was developed correctly. The tester could easily be updated with ammendments/editions as a simple firmware update to ensure it's doing it correctly.

    @JoannaHammond@JoannaHammond2 жыл бұрын
  • Great Video buddy. Have to laugh at how thorough you are when you think loads won’t take the cover off the damn consumer unit let alone a blank plate of an unused circuit 😂👍🏻👍🏻

    @rattlehead85@rattlehead853 жыл бұрын
  • I use the long thin probes on the megger tester for the Rcbo's at a consumer unit as the standard Gs38 probes dont Reach far enough into the live terminals

    @paultipton743@paultipton7433 жыл бұрын
  • Hi Jordan Notice you use the remote button on the test probe. Not really needed as the fluke auto starts zs test. Always found that remote probe can give odd readings. Any reason you use it ??

    @dlewis129@dlewis1293 жыл бұрын
  • Good video , did you fit a 6 monthly rcd test notice

    @Mainly_Electrical@Mainly_Electrical3 жыл бұрын
  • As long as there's different depths things we will never be able to standardize on probes. There's a finger guard there for a reason and they should be used by professionals who have the training or at least the wear for all to read the manual. Your fingers shouldn't be touching the metal of the probes when you're using them. Which is why I say and have had to take the Caps off and then out of fear of losing them just leave them off. Granted I am in the US with only 120, 240 V the only time I had an issue was when I tried to do something stupid sorted and the box was very tight and I tried to get to a terminal screw without removing the device and grounding it to the Box. I wasn't getting good readings from the socket and managed to bridge my pro-tip between the screw and the Box that was metal I put a nice gouge in it. And I think I was also dealing with a Federal fire Pacific panel....

    @imark7777777@imark77777773 жыл бұрын
  • Good video Jordan 👍🏻. Have you tried the Kewtech Lightmate adaptors for testing? They are handy to have in your test kit

    @seanboxley4594@seanboxley45943 жыл бұрын
  • What you should mention also is how to change the battery on the 'Hardwired' smoke alarms, as it has a memory to warn you the battery needs to be changed.

    @timg6850@timg68503 жыл бұрын
  • There's a reason GS38 shrouds are removable. If you're self-employed, use what works while understanding the risk. Different if your employer expects you to do something impossible.

    @lumpyfishgravy@lumpyfishgravy3 жыл бұрын
  • Yes Re is R2. As originally specified, the 1653 was a pan-European tester and some countries (eg NL - I think) place more emphasis on Re than Rle. However, I have no idea why it's only one decimal place.

    @lumpyfishgravy@lumpyfishgravy3 жыл бұрын
KZhead