How to Install Underfloor Heating in an Old Property

2024 ж. 22 Мам.
83 450 Рет қаралды

How I installed a water based underfloor heating system in my old property, from insulating the floor, to installing the pipes and manifold, and what screed I chose.
This is the second video in the series. The first video is here bit.ly/48kvoAq
I knew very little about underfloor heating before I started this project and I've pretty much installed the entire thing myself. I've learnt a lot along the way and I'm hoping you can too, from watching this vid.
You can become a Charlie DIYte Patron here
- / charliediyte for exclusive behind the scenes content and access to my Discord chat forum.
0:00 Introduction
1:05 Water Main Prep Work
1:32 Pipes Through the Brickwork
2:30 Insulating the Floor
7:07 Laminon membrane
8:31 Choosing your UFH System
10:20 Installing the System
16:10 Flow & Return Pipes
19:15 Filling the System
22:34 Drayton Underfloor Heating Controller
22:42 Choosing your Screed
25:50 System Performance
27:51 Drayton Wiser integration
28:27 Subscribe to Me!
USEFUL LINKS
- Video 1 in the series bit.ly/48kvoAq
- E Tupling bit.ly/48Exk6C
- Cemfloor bit.ly/48jPN8A
- Ryflow bit.ly/48hv59s
- www.laminon.co.uk/
- / @laminon1284
TODAY'S TOOLKIT*:
Components of the UHF system:
- premium pipe tacker gun bit.ly/3NR5U5h
- 60mm staples (5 boxes of 300)
- edge foam 150mm x 25m roll
- Laminon membrane www.laminon.co.uk/
- maincor 16mm pert pipe 150m coil
- Danfoss 9 port SSm 9+9 manifold set DF88U0659 includes 16mm eurocones and colour coded isolation valves
- Danfoss FHM-C1 mixing shunt & GFOS pump
- Danfoss HP22 / 2 port valve
- Danfoss thermal actuator 230v x 9
- Fastwarm 16mm x 16mm straight coupler
- Fastwarm manifold blanking cap
- Manifold fill, drain valve pair & auto vent bit.ly/48hUX4T
- Drayton Underfloor Heating controller geni.us/tguxn (Amazon)
- SKIL 3540 20V Compact Brushless Multi-Material Saw bit.ly/3PrUAwx
- SKIL 3520 20v CIRCULAR SAW (not currently available in UK)
- SKIL 3851 CA PWRCORE20 sds DRILL (not currently available in UK)
- SKIL 3225 20v Impact Driver bit.ly/464MS2j
* The Amazon links above are affiliate links. It doesn't cost you anything to click on them but I do earn a small commission if you do.
And here's the legal bit I have to state: As an Amazon Associate I earn from qualifying purchases.
SUBSCRIBE - you can subscribe to my Channel here: bit.ly/3DEE2dI
LET'S CONNECT!
Charlie DIYte
-- / charliediyte
-- Email: charliediyte@gmail.com
-- / charliediyte
-- Web: charliediyte.co.uk/
-- / charliediyte
#underfloor #heating #install

Пікірлер
  • 🛠Charlie DIYte Amazon Tool Store amzn.to/3fcLnY4 - all my tried, tested and much loved DIY tools. ☕ Help support me on Patreon -www.patreon.com/charlieDIYte (includes Discord access). 🛍 Join me on WeShop and earn shares every time you buy! - app.we.shop/join-charliewhite

    @CharlieDIYte@CharlieDIYteАй бұрын
  • What a legend Jim is 😊 wow you never fail to amaze me Charlie taking on these projects and completing them so well.

    @karlpopewoodcraft@karlpopewoodcraft4 ай бұрын
    • I love your videos as well Karl

      @gregp1707@gregp17074 ай бұрын
    • @gregp1707 Thank you Greg 😊

      @karlpopewoodcraft@karlpopewoodcraft4 ай бұрын
    • Thanks mate. Hope all's well with you guys 👊

      @CharlieDIYte@CharlieDIYte4 ай бұрын
    • @CharlieDIYte Cheers mate we are well thanks 😊

      @karlpopewoodcraft@karlpopewoodcraft4 ай бұрын
  • My underfloor heating system is now over 15 years old. It really has come along way from my old 16mm pipe version. It’s by far the best thing you could have done. Not just because it is beautiful to stand on warm tiles but our heating bills are tiny compared to friends with smaller properties. The set up and balancing is still a nightmare and I could only dream of a design and flow rate diagram and manifold so easily adjusted as yours.

    @James-po4xt@James-po4xt4 ай бұрын
  • Wow Charlie. You’ve become quite an expert on under floor heating. Superb research and consideration of all the pros and cons. I’ve definitely learned a thing or two here. I imagine you’re delighted with the result and can slowly get your home back in order. I’m looking forward to the next one. All the best for the New Year and another busy one at that I imagine. Cheers. 👍🏼

    @paulrowley71@paulrowley714 ай бұрын
  • Thanks for sharing, Charlie, and Happy New Year!

    @MrJohnnynapalm7@MrJohnnynapalm74 ай бұрын
  • The layers and details are really carefully built. Lots of care taken, which will serve you well. Nice.

    @eleycki@eleycki4 ай бұрын
  • Brilliant as always. Thanks for explaining in detail. Looks fantastic.

    @ElekTrikPurple1@ElekTrikPurple14 ай бұрын
  • Just wow Charlie! Such a steep learning curve I’ll have to watch this video again to take it all in. Great job and great explanation of the process. You should be very proud of the end result

    @gregp1707@gregp17074 ай бұрын
  • Hi Charlie, I strongly recommend that you abrade/ scarify the top layer of your screed which is referred to as the skin, this process removes the loose material, bubbles and ripples that you talked about but more importantly it help with the moisture evaporate from the screed to help in the drying process and final when you lay tiles or anti cracking mating the adhesive will have a more secure bonded to the screed but if the skin is not removed the you run the risk of the whole lot moving and losing over time.

    @Bryan-rj3kn@Bryan-rj3kn4 ай бұрын
  • I've used Ryflow on my last two installs and couldn't be happier with the service. Very skilled and highly knowledgeable crew.

    @davidquirk8097@davidquirk80974 ай бұрын
  • Been looking forward to this one for quite a while now. Great stuff Charlie!

    @MatthewJohnSmart@MatthewJohnSmart4 ай бұрын
  • Great videos 👍 didn't realise a floor plan was needed for the UFH Need to get that sorted asap

    @thejamalc@thejamalc3 ай бұрын
  • Fantastic video, amazing to see this documented. Nice one Charl

    @suj1945@suj19454 ай бұрын
    • Thanks so much 👊

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Impressive work Charlie

    @philipwilliams8114@philipwilliams81144 ай бұрын
  • will be a good video to watch about moving the water main pipe.

    @jackinnes8599@jackinnes85994 ай бұрын
  • Great video, thanks Charlie

    @ridgmont61@ridgmont614 ай бұрын
  • Nice video I ave been installing UFH for 40 years and have seen its progress to where it is now. The big thank you on this video debunking the id that you should not run your pipes to over all area of the kitchen. The number of disagreements I have had with customer who listen to the wrong advice. Then cannot give rhyme or reason why. When been called in to investigate why a particular floor is not preforming out comes my thermal camara and surprise surprise I more oftan than not find no pipes under Island or units and or the use of 200mm centres. All lead to a uderperfoming system. If it’s too warm it can be commissioned to perform correctly including the correct setting of the programmable room stat. If it’s not warm enough you have wasted your money. To be honest I do put some blame on the competitive nature of the suppliers as it’s seen as a cost saving excercise to miss out a few hundred metres of pipe, that gives the industry a bad press. I start my next new build install first week in Feb. Good luck. Regards Michael M

    @michaelmurphy8826@michaelmurphy88264 ай бұрын
  • Jim & the team at E Tupling are the best in the business ♥

    @macdonaldplumbingheatingsupply@macdonaldplumbingheatingsupply4 ай бұрын
  • This is fascinating stuff. Had quotes for an air-source heat pump that I like the look of, but having no radiators (warm air system currently) so this is exactly the insight I was looking for. Though very unlikely to DIY it, these tips make it much easier for me to find a contractor that knows what they're talking about. Bravo and Happy New Year

    @nicomonkeyboy@nicomonkeyboy4 ай бұрын
    • If you already have a warm air system and switched to a heat pump could you keep that air system and then benefit from the fact that a heat pump could or should be able to run "in reverse" as air conditioning in the summer? Probably some challenges involved with retaining hot water in that scenario but I don't know...

      @__Ben@__Ben4 ай бұрын
    • @@__Ben I had planned to remove the ducting, but that is a _very_ interesting thought. Will make the install even more complicated, but as Charlie said, future-proofing is crucial - and imagine having proper AC in our ever warmer and muggier summers?! Thx

      @nicomonkeyboy@nicomonkeyboy4 ай бұрын
    • @@nicomonkeyboy I think at this point when I eventually get a property I'd at the very least air condition the main living areas and bedrooms now, would be amazing...

      @__Ben@__Ben4 ай бұрын
  • Nice video Charlie! Thanks for always sharing with us' and Happy New Year!💖👍😎JP

    @IEnjoyCreatingVideos@IEnjoyCreatingVideos4 ай бұрын
  • If you are ever doing an in depth refurb like this or new build underfloor heating is right up there on the top of the list. Coupled with an ASHP it is just amazing to live with. If well insulated it can help heat the whole house with just a few smaller rads upstairs to top up the temp when required.

    @Jamessansome@Jamessansome4 ай бұрын
  • Incredible video, just what I’ve been looking for! You get a subscriber 👍

    @thewonderfulparadox@thewonderfulparadox3 ай бұрын
  • We commented when you started this project and must have completed about the same time. We have a heat pump and Loxone control so that will be interesting. We recently parted with our builder but your comments on insulaton give us some concern. Our builder used 25mm PIR around the sub-base but we found most of that floated up and was removed. We have the expansion gap insulation around new walls which are very well insulated. We are not sure we really got what we wanted in that regard. For the screed we are very happy as we used the same Chemscreed solution which was very flat overall and allowed some adjustment for levels across the build.

    @JurassicJungle@JurassicJungle4 ай бұрын
  • Well done Jim for saving the day.

    @UpsideDownFork@UpsideDownFork4 ай бұрын
    • Yep he's been great. 👌

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Great stuff. Thank you

    @brownhouse16@brownhouse164 ай бұрын
  • Great job as always! This breathable wall Charlie, I'm a little concerned that any wall containing plasterboard will not be breathable - I've been unable to find the vapor resistance of normal plasterboard tonight however. Please do ask lots of questions before fitting it and don't be afraid to go with a wood fibre and lime plaster solution if better. All the best for 2024 😊

    @pumpkinhead456@pumpkinhead4564 ай бұрын
  • Great stuff, I did an almost identical job on our 1790 farmhouse in the French Alps. Having never done it before came to the same solution for the concentric pipe layout but used pex-al-pex. Was suprised how many suppliers didn't use that as default so in the end drew everything on sketchup myself to get the pipe lengths even. Had 600mm solid walls, underpinned then insulated the outside, line plastered inside and installed a double flux ventilation system. Never had an issue at all with mould or damp...7 years in. Run the UF at 28°c to 32°c keeps the house at 21 or 22° whilst it's sub zero for 3 months... Very happy. Looks like you've done a top job... Just wish you'd have posted this video 7 years ago as i wouldn't have had to do my own research...😂😂😂😂

    @alptastic@alptastic4 ай бұрын
    • You've aced that 👌👌 - excellent work!So basically an MVHR system? The underfloor is incredible. I've got it on about 32 degrees right now and it's heating the room effortlessly to 20 degrees and that's before I've installed the wall insulation.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
    • @@CharlieDIYte yes MVHR your correct, sorry, double flux is the French description. It's a total faff and not cheap if you get someone to do it, so of course I did my own, but it's totally worth it, especially if you have any slight concerns regarding old walls, breathing, moisture retention etc. I have a 50m underground 200mm pipe supplying the fresh air to the unit in through the boiler utility room, so any residual heat from the pellet boiler, fridge, freezers etc add their calories to the incoming air before it's pumped into the house. Totally agree, Under floor heating is a game changer, it's utterly wonderful. Great channel, love your style, just 7 years too late for me.... But keep it up..

      @alptastic@alptastic4 ай бұрын
  • I installed an underfloor water heating system because my eldest son was severely disabled and we did various stretching exercises with him on the floor. The warm floor was great for him.

    @MrCraigShepheard@MrCraigShepheard4 ай бұрын
  • class work Charlie got a wet under floor heating to put in my house I removed all the old wooden floors last year

    @jimmy4952005@jimmy49520054 ай бұрын
  • Wow - great job

    @onepairofhands@onepairofhands4 ай бұрын
  • Future proofing for a heat pump, very wise!

    @edc1569@edc15694 ай бұрын
  • Thanks great video

    @papabear920@papabear9203 ай бұрын
  • First thing you should do is remove that mixing valve/ pump from manifold and suply system with proper lower temperature ,your boiler will save energy by working on lower temperatures.

    @786otto@786otto2 ай бұрын
  • Thank you for that insight, it was very thought provoking because I would like to know if it would be possible to do a similar system with my Stove Boiler (which is only used in winter), and perhaps at some later point, updating that too, to be able incorporate a SunAmp heat battery in the future, but do it in a way that it can be future proofed.

    @dewarmc@dewarmc4 ай бұрын
  • This was great.

    @cnut4563a@cnut4563a4 ай бұрын
    • Thanks 👊

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Very good and comprehensive video Charlie, shame you kept butting in when Jim was explaining the flow details 😮

    @jimgeelan5949@jimgeelan59494 ай бұрын
  • Not just a good idea but absolutely essential to have a seperating membrane between the screed and the foil faced PIR insulation, the screed will dissolve the aluminium and the gases generated can weaken the screed, plus it wont comply with building regulations without the membrane being there.

    @mikebarry229@mikebarry2292 ай бұрын
  • fantastic explanation as usual. Well done. Your busy with so many improvements maybe the next video should be about where you get the time and money from ;-) atb

    @opentrail@opentrail4 ай бұрын
    • Thanks, I really appreciate that. It's a good idea. Just not sure how many people would watch it 😉 The time comes from doing this full time. The money is the problem. We're pretty skint right now but after living in the house for 13 years with so much wrong with it we decided to bite the bullet.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Charlie you are a rock star. Great video, excellent install!

    @jyoung9181@jyoung91814 ай бұрын
  • I agree the manifold position by Polypipe could have been better, the cupboard would have been perfect, The manifold was meh nothing special and, I personally wouldnt want heating under kitchen units for numerous reasons, regardless of insulation. Charlie having used those caps in the past, I'll stick to my trusted keyring, happy New Year my friend hope to do more in the future.

    @M4RTLTD@M4RTLTD4 ай бұрын
    • You too. Really appreciate your help on this 👊

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • It's saves a lot of money, keeps longer temperature , is more healthy. Very good idea you invest in your property. Shame UK is wake after years to upgrade houses .

    @arekarek1991@arekarek1991Ай бұрын
  • Weather compensation is the answer to your minimum cycling, maximum efficiency question!

    @hk78901@hk789014 ай бұрын
  • Great Video Charlie, loving the content on this renovation keep up the good work 👍👍 Hi Charlie just to add to this? Your discord forum, can this be used for me to discuss questions I have with other members of I have a DIy question to ask?

    @MrLegend139@MrLegend1394 ай бұрын
  • Thanks for this series. I’m planning on doing a similar scheme in a (very cold) 1970’s house next year so watching intently… I’ll look forward to the next update.

    @Shane_O@Shane_O4 ай бұрын
    • You're very welcome. By far the most expensive part of it is the excavation and prep. The actual kit cost just over a grand with the small discount I was given. But the screed was nearly double that, as was the concrete slab and of course the builders fees. I'll try and get a video out on the costs at some point. It probably isn't worth it cost wise but in terms of creating a lovely warm environment, future proofing for heat pumps etc it's worth the cost.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
    • I did wonder if we'll see a heat pump vid in a year or two. I was looking out for signs of a ground-source circuit being laid when you had the digger in the garden.

      @georgehavey@georgehavey4 ай бұрын
  • Thanks Charlie. Welcome to 2024. Take care & stay safe.

    @dougdavidson175@dougdavidson1754 ай бұрын
  • QUESTION: I have been umming and arring about whether to DPM or breathable on my underfloor heating system in my 200 sandstone cottage. I have seen a few videos online where people have installed DPM under a concrete floor and the damp has travelled horizontally under the DPM to the edge of the slab and crept into and up the walls straddling the concrete slab/screed. Would you so a video with a thermal imaging camera to see if your DPM has done something similar in your cottage? P.S Your videos have been a god send for my DIY project on my old cottage.

    @RATHER5KEPTICAL@RATHER5KEPTICAL8 күн бұрын
  • Thanks for the video Charlie. Love your channel and this is a particularly useful video for me as I would like to install something similar in a similarly old building. What has kept me up at night is how the walls below the floor are able to breathe and release moisture once the floor is installed directly up to them. Is there a risk of wicking up the insulation and crossing the DPM? Yours or other people thoughts welcome.

    @stephenshapcott1353@stephenshapcott13534 ай бұрын
    • Thanks Stephen. That's the job of the damp proof course. I don't have one in my old place but did get it injected back in 2010 when we moved in. I think as long as your levels outside are low enough you should be able to manage the damp with or without a damp course. The floor used to be very cold and damp particularly in the corners. Putting the damp membrane below the screed has made a massive difference and if you're worried you could always continue it up the wall.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Hiya Charlie, I'm going to be converting our integrated garage and a ground floor bedroom into an open plan kitchen diner in a 60s townhouse. The architect recommended Wunda wet system which users a 20mm thick Insulated pre routed board. Only 16mm pipe and as low hight I can use it for both garage and existing concrete floors. They did a drawing and the flow and return is not running next to each other. So this is something to think about having watched your video. I have installed my own radiators and and ran copper pipe everywhere so I'm hoping I will have the skills to install this system. The builders can do the screed. Wunda have shown no pipes under the cabinets but The underfloor heating company who also provided a quote have indicated to have the pipes everywhere to presumably avoid coldspots. I am eager to see your next video as my architects drawing shows tile adhesive directly on top of the screed. Thanks for sharing your experiences. Aaron

    @aaronharris5275@aaronharris52754 ай бұрын
    • Thanks Aaron. All sounds good and you'll definitely have the skills to do this. With these things it's always a case of adapting to the situation. Probably won't be for a couple of months but I'll definitely be doing a vid on it. 👊

      @CharlieDIYte@CharlieDIYte4 ай бұрын
    • @arronharris5275 If you go with the Wunda system (or any similar foam board type overfloor system) make absolutely sure the boards adhere well to the floor with no areas of creaking or movement. We used the Wunda system you mention about 3 years ago to do our entire ground floor and initially started with their spray glue to stick the boards down, but it's really not up to the job in my opinion and is especially useless in cold room temperatures (which is obviously common with house builds/renovations when the property isn't heated) meaning boards started popping and lifting off the concrete floor within days of laying it. The Mapei board adhesive they recommend you apply like tile adhesive is better but still wasn't infallible, we ended up finding areas lifting after we'd laid the 10mm screed over top which led to movement and cracking of the screed, luckily discovered before we put the final LVT and tile flooring over top but still almost impossible to rectify without pulling it all up and starting again. Faced with tearing it up as the only other solution which wasn't viable I ended up borrowing a thermal imaging camera to identify where the pipe runs were, drilling holes between them, squirting a little adhesive down through the hole to hopefully get in under the gap then use screws and large washers to mechanically fix those areas down. This did work but no thanks to Wunda who basically blamed the install and washed their hands of it even though all their install instructions were followed.

      @LocostR1@LocostR14 ай бұрын
    • I've since also ditched the mechanical blending valve on the manifold which also don't work very well, sometimes seeing spikes of flow temps into the manifold way higher than they should be. By far the best way to feed UFH is to have a boiler or heat pump with weather compensation and (if it also needs a second zone to run upstairs rads at higher temps) electronic mixing valves to electronically mix the right flow temperature for the floor based on the outside temperature meaning you end up with a simple flow and return pipe to the manifold that's pre-mixed to the right temperature. We've now got that with our Vaillant boiler and controls, the boiler basically runs pretty much 24/7 at very low output during winter feeding low temperature water to the floor and oversized rads which are on a separate mixing valve to get the slightly higher flow temps required. Other than for hot water cylinder heating the boiler flow temperature rarely goes above 45c unless it's really cold with the floor generally running at 25-30c flow and rads at around 40-45c. Because there's always some heat going through the system the house temperature stays incredibly consistent through the day regardless of weather temps and the best bit is despite the added comfort we use no more gas than the previous "smart" controls that basically just fired the boiler at a fixed high temperature on and off based on demand then relied on the mixing valve on the manifold to modulate the flow to the floor.

      @LocostR1@LocostR14 ай бұрын
    • @@LocostR1 Hello, thanks so much for taking the time to write this really useful information. I had wandered how well the spray adhesive would work on a cement based surface. It would have to be dust free, bone dry and no rough patches such as air bubbles. I will have to take this into consideration as it would be a disaster if the insulation starts lifting up or creating cracks in the upper layers. Thanks again Aaron

      @aaronharris5275@aaronharris52753 ай бұрын
    • I will try to get my head around this as its very technical and I'm just getting to grips with the system which has been specified and unsure exactly which components I would receive. Its sounds like you have experienced a lot of inconvenience but have come out the other side with a good deal of knowledge and experience! @@LocostR1

      @aaronharris5275@aaronharris52753 ай бұрын
  • Brilliant. I remember seeing the video ages ago. Glad to see part 2. Did you pay the VAT on the materials and the work by the consultant with it being a DIY job?

    @adamuk73@adamuk734 ай бұрын
    • Afraid so. It's a benefit in kind so can't put this sort of stuff through the business.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • @6:15 where you mention the insulation height was too much, I'm assuming extra thick screed at what is now a low point is not an issue? I have variations of upto 20mm in 2 rooms. Ive identified the high points and calculated my insulation thickness at this point. I will also have a 5mm difference between the finished insulation height bewteen 2 rooms! Ill be using 16mm pipes in minimum 50mm screed, so will have 34mm miminimum coverage of the pipes. Im relying on the liquid screed to fill the low points in the insulation and leave me with a level floor 👍

    @y002cjw@y002cjw2 ай бұрын
  • Hi Charlie, great video and quick question regarding the upstands you used. They 25mm thick and what height did you cut them off at? am I right in saying height of PIR board (100mm) plus the height of screed at 50mm, so were your upstands a total of 150mm. Thanks and keep the videos coming

    @kaitsui@kaitsui3 ай бұрын
  • 2:37 a heat sink floor!

    @raftonpounder6696@raftonpounder66964 ай бұрын
  • Great video, im installing electric heated flooring for the 1st time, I noticed the thermostat for it is about 2x the price as a regular thermostat, not sure why

    @trix4meow@trix4meow4 ай бұрын
    • Because it needs to be rated for the power draw of the floor not just a low current switch. Resistive heating for a floor will be ridiculously expensive to run.

      @Swwils@Swwils4 ай бұрын
  • Is this everyone first time on KZhead. Come on guys!

    @Lewis714@Lewis7144 ай бұрын
  • Im glad you showed how tricky it was handling the pipes..did you get any kinks at all?

    @chelps6411@chelps64114 ай бұрын
    • No kinks. You just have to be a bit careful on the bends not to make them too tight as that's the point they're most likely to kink.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Hi Charlie, What an excellent video. I'm in the process of trying to work out if it is better to buy an older property and do the underfloor heating myself (do it myself or get a professional in), or to buy a property with it already installed. The question is how reliable are the new builds now-a-days?

    @pauladebt2753@pauladebt2753Ай бұрын
    • Thanks Paula. I think it all depends how close together they laid the pipes and therefore how efficient it is. Also if you buy an existing and don't like the lay out of the kitchen for example, you might have loads of cold spots if you move the units assuming they haven't laid pipes under the units. However it's very expensive to retrofit!

      @CharlieDIYte@CharlieDIYteАй бұрын
  • Fantastic video. Bet you’re glad you have a floor now! I’m guessing the downsides to this system is the time it takes to heat up the house? Whereas with rads you can warm up a room quite quickly the floor will take longer. But I’m guessing it’s going to hold the heat massively too. So overall more efficient? Also no wall space taken up by rads too haha

    @Chriskreepa@Chriskreepa4 ай бұрын
    • We have underfloor heating in our house upstairs and down...Best way to run it is have it on all the time, have downstairs stats set at 22 and upstairs at 19, heating kicks in if they drop 1 degree, only takes 30 mins to bring back up to temp. Initial warm will take a while but quick after that.

      @andyjackson2269@andyjackson22694 ай бұрын
    • We have ufh in one room - 11mx4.45m. We set it to a minimum of 13c after 22.00 then it clicks on after 06.30, with a max of 19c throughout the day. It usually only drops 3-4c per night in the winter. It takes circa 1 hour per c to heat (if pipes are cold). We have 100mm insulation with a 70mm screed with vinyl on top. 40c flow temperature on mixer. The heat is very clean/natural, rather than the blast of a series of radiators, you also have warm feet, which is a nice feeling.

      @antlet@antlet4 ай бұрын
  • Hi Charlie, I know you are busy atm but just wondered what advice you got for laying pipes other than ufh (boiler flow and return, hot water). In my case i have to run approx 9m of flow, 9m of return and 9m of hotwater pipe, from the boiler to the manifold. Im wondering should i secure this o tge concrete subfloor then lay 100mm of insulation, or lay my 100mm of insulation, then neatly gouge out insulation and slip pipes into the insulation as you appear to have done at 6.10 in this video. TIA. Also did you just spray foam around your copper pipes then tape over?

    @y002cjw@y002cjwАй бұрын
  • Thanks for the video, I'm currently planning and costing this job and the slab in an old cottage so a similar situation to yours. Limecrete or concrete...hmmm. I have reached out to Jim's company for a quote but did you consider nu-heat and how did you select your UFH supplier? Thanks

    @oc1625@oc16254 ай бұрын
    • You're welcome. I tell you, that room is so toasty warm right now and I haven't insulated the walls yet. I thought about nuheat but in the end, I gave it to Jim because he reached out, and gave me such good advice.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • I have a 1950's bungalow and I really like the idea of installing UFH while we gut, rewire, re-plumb and re-decorate. However the floor is concrete, I've seen videos and information that state you can lay an insulated board that the UFH pipes lay in and it has a surface "diffuser plates" that help spread the heat upwards from the pipes. Would you recommend this setup or is it a case where if I want UFH then I'll have to excavate the entire floor and start again?

    @SouthCoastFinest@SouthCoastFinest4 ай бұрын
    • That overlay is a good option 👍

      @cameroncook97@cameroncook974 ай бұрын
  • Great job, Charlie. It looks as if your house will be nearly ready for a high efficiency heat pump install (although you may need to change the manifold to remove mixers and the actuators). Have you considered using an MCS umbrella scheme (for the £7,500 government grant) and doing the install yourself? Out of curiosity, was there a reason you didn't use MLCP pipe(e.g. PEX-Al-PEX) on the 22mm run from manifold to existing system? That might have saved a load of copper bending, although I suppose some people find that therapeutic!

    @asabriggs6426@asabriggs64264 ай бұрын
    • Thanks. Yes we should hopefully be ready for a heat pump when the time comes. I was thinking exactly that myself recently about that pipe run. Don't know why I didn't use plastic - as it would also have removed the need for that join under the floor. Also I'm slightly gutted I didn't put the manifold in the cupboard - would have made so much more sense and removed the need for that pipe run. Still you live and learn. 👊

      @CharlieDIYte@CharlieDIYte4 ай бұрын
    • @@CharlieDIYte I am moving towards the perspective that MLCP pipe is easier to use and cheaper than copper, and produces join-free work. The only downside is the cost of crimp fittings and tooling, although there are now U-profile manual crips for around £70. Ideal for DIY-ers, if only we knew about it. Hindsight regarding the manifold location is a wonderful thing, but equally pushing a project forwards is very important. Thanks for sharing your introspection.

      @asabriggs6426@asabriggs64264 ай бұрын
  • Whats the guide costs to remove the floor.. and so on. With an older property, that's got to be a lot of work.

    @rowifi@rowifi2 ай бұрын
  • Nice. Why zone it at all?

    @Swwils@Swwils4 ай бұрын
  • My take away: all but a DYI job ! Seems like a minefield, let's keep our fingers crossed it will last 20 or 30y, a lot of plastic in this install. Would have been interesting to have an overview of the cost for such an install, must be serious cash. I will need to look into this at some point, not looking forward to it, even though there is no question that comfort is second to none.

    @jeromeuk@jeromeuk4 ай бұрын
    • Interesting comment. I had plastic piped UFH installed in my self build in 1998. I wonder if they've got wet feet there...

      @angiej4865@angiej48654 ай бұрын
    • @@angiej4865 it's not so much the plastic pipes burried in "concrete like" that worry me. It's rather the ramp of plastiky connectors and valves. There will be adjusments, purges, bleeding etc over time, I am just hoping this will sustain the test of time. Not obvious to me. I guess relative to the overall cost of the install that's probably a detail.

      @jeromeuk@jeromeuk4 ай бұрын
    • Not all plastic is the same, and many of the things that age plastic, big swings in temp, UV radiation and repeated flexing will be minimised when it is encased. Also it looked like a thick walled pipe. I reckon that will last for a looooong time. What other material would you use??

      @georgehavey@georgehavey4 ай бұрын
    • You don't know what you're talking about, speak to an expert.

      @YeahNoTellTheTruth@YeahNoTellTheTruth4 ай бұрын
    • @@jeromeuk The general practice and recommendation from the European manufacturers (who've been supplying this stuff for a very long time) is no joints whatsoever in the buried pipes. Also, circuits should be limited to no more than 100 metres per circuit. If you have a large room this means more than one circuit per room. Also, not all UFH pipes are equal. They vary in heat transfer capability, oxygen permiability and cost. A good supplier sells the pile cut to length (you have to allow some extra for installation, etc.). I used Ryflow (the same company used in the video) for the liquid screed installation and they are very knowledgeable and can also do a lot of the pile installation too. Costs wise, back in 2017 when I did my second full install, the manifold, fittings, pipework and individual room thermostats cost me around £1500. Screed cost for two large rooms (4.2 x 3.6m each) came in at around £1200.

      @davidquirk8097@davidquirk80974 ай бұрын
  • Can you install UFH on ground floors that have a cellar underneath and on floors above the ground floor (e.g. upstairs)?

    @Christopherfife@Christopherfife4 ай бұрын
    • Yes absolutely. Depending on the nature of the floor - concrete slab, timber etc you just choose a system to suit.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Just out of curiosity how did the whole system cost as as I’m looking at doing something similar on a budget if that’s at all possible

    @ChrisLivingInYork@ChrisLivingInYork4 ай бұрын
  • How would you rate them skil tools you have? I was thinking about purchasing them myself.

    @MSGaddicts@MSGaddicts4 ай бұрын
    • I'm loving them, mate - I don't think you'd regret it. Decent life on the batteries and I like the fact the dual charger charges both batteries at once which is more than can be said for my Ryobi multi charger station! The impact driver with its multiple settings is particularly good and the SW1E3540CA multi material saw (basically a mini circular saw) that I used in this vid kzhead.info/sun/opipY9qKoKShpps/bejne.html is a fantastic little tool. There are a couple of tools not available in the UK yet, like the RH1E 3851 20v SDS and the random orbit sander, but they have a good old range at Screwfix.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • What brand of boiler do you have. A lot of them have a module available in Europe (the Netherlands in particular) to allow open therm integration and they will work with UK boilers.

    @zakthetech@zakthetech3 ай бұрын
  • Does anyone know how to calculate the head side of a pump for UFH application? My understanding is the pressure loss show in the installation table later in this video shows in Pa the equivalent of head loss. So 20,000 Pa is equivalent to 2m of head loss. Is that right? It so when all circuits are open in this installation what size pump would be required? I currently have a 6m pump and it’s not enough. I have 11 circuits, most ~100mm 16mm

    @GrahamDIY@GrahamDIY4 ай бұрын
  • Hi there please help. The fan in my bathroom was pumping steam etc into my lift space for a couple of months until I got a new fan fitted. I now have mold growing all over my loft. What should I do now 😢😢😢???

    @helenalovelock1030@helenalovelock10302 ай бұрын
  • Is the screed anhydrate based? How was the process of removing the laitence if so? any concerns of having difficulty of flooring not binding? Great video once again, really insightful 👍

    @joshuaevans5213@joshuaevans52134 ай бұрын
  • You didn't talk about the type of pipe you used. Polypipe would have been a 15mm system you went with a European 16mm system. You didn't mention that your pipes are barrier pipes. I assume they are. You can also get multi layer pipes such as Pex-Al-Pex and Pex-Al-Hdpe. Whilst those are harder to lay, they are stronger and built better.

    @imranbashiruk@imranbashiruk4 ай бұрын
  • so which system do you likebest?? How do I get in touch with JiM?? and who can install mine

    @jennifermedia6288@jennifermedia62884 ай бұрын
  • Those auto balancing valves look like TRVs minus the head.

    @Hambini@Hambini4 ай бұрын
  • Looking for advice just purchased a bungalow built 1960s electric underfloor heating. Do I keep it or dig it up and install insulated wet underfloor heating 100ms floor area

    @reiksrayb@reiksrayb4 ай бұрын
    • You've got 2 issues with that electric system. 1. Electric systems cost a fortune to run and 2. insulation below the system will be non existent in a 1960s install - which in turn contributes to 1. Have you experimented with the system? Cost, efficiency etc? That was very innovative installing that in the 60s.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
    • @@CharlieDIYte getting the key’s and of month the room stats look of the time of installation the roof area looks good for double aspect solar, the walls have cavity but no insulation. Won’t to make the house as economically to run as possible without costing a fortune I have no idea the cost of digging the floor area up and installing a better insulated floor could I just install wet underfloor heating on top of the existing floor with minimal insulation so as not to lose height and have to cut to much of the doors, O and we live on an Scottish island.

      @reiksrayb@reiksrayb4 ай бұрын
    • I appreciate your help

      @reiksrayb@reiksrayb4 ай бұрын
  • Are you not concerned that the system has been designed for 35° flow but at what outside temperature? If you have it set to 35° now at 8° outside and only achieving 19° inside (which is quite cold) then at -2° you will need closer to 45° flow temperature I would guess and does your system achieve this? My UFH flow is set for 45° at -2° outside temperature with weather compensation.

    @neilbridgeman7768@neilbridgeman77684 ай бұрын
    • Don't forget I've got the room thermostats at 19 right now. I can bump them up to 22 and it'll simply mean the system is on a bit longer but at the same flow temp and when I've insulated the walls the demands on the system will be even less. The temp in that TV room is consistently around 25 so I actually need to adjust down the auto balancing valves in there I suspect.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Amazing set up mate! Cost.... Don't be shy.

    @richardfife8192@richardfife81924 ай бұрын
    • Thanks Richard. I'll do a vid on the cost. The kit itself was about £1400. What makes these systems really expensive to retrofit is the cost of excavation, insulating etc.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • Great job but personally i would have put a limecrete floor with foamglas insulation as you have solid walls. Risk of damp pushing up walls as cant escape. Otherwise looks good.

    @jonbryant9352@jonbryant93524 ай бұрын
  • Oh dear

    @keithr1814@keithr18144 ай бұрын
  • No sound Charlie

    @leestafford3547@leestafford35474 ай бұрын
  • Missing sound

    @bobocionutalexandru@bobocionutalexandru4 ай бұрын
    • There is sound, the problem is that the video has only processed to 360p so far and on some clients (usually mobile?) Audio doesn't work on that quality level for a few hours after upload.

      @__Ben@__Ben4 ай бұрын
  • Haha... it took all of 20 seconds and I'm going: "nah - radiators for me" 🤣 Just can't see how this is possible if your family is actually living and working in the house during all the work.

    @marcuscooper9544@marcuscooper95444 ай бұрын
    • I boarded up the room and moved the entire kitchen into the hall. Family are getting fed up now though, living in 2 rooms for nearly a year. 🤦

      @CharlieDIYte@CharlieDIYte4 ай бұрын
  • That all looks expensive

    @TheOffroader7458@TheOffroader74584 ай бұрын
  • Is this only available in 360p?

    @Quickblood1@Quickblood14 ай бұрын
  • Has things gone tits up?

    @dr6124@dr61242 ай бұрын
  • Hi Charlie, im a heating engineer and there are things you can do to increase efficiency and reduce boiler cycling. What boiler do you have?

    @jacbisgood2221@jacbisgood22214 ай бұрын
    • Is there any way to contact you, I would love to pick your brains regarding my system, which is also a wet ufh running off a combi that I think could be made more efficient.

      @imranbashiruk@imranbashiruk4 ай бұрын
    • Watch his old videos

      @chrisohanlon69@chrisohanlon694 ай бұрын
  • The problem with any encapsulated system is you can’t know what is going on , copper pipes run under suspended floors always have the opportunity for inspection and repair . But of course this tends to come at the price of thermal efficiency , so we find ourselves in a difficult position . Greater efficiency over less efficient systems as in radiators , and again here is the main stumbling block . Systems that rely on radiators irrespective of how large the radiators are need a far higher water temperature than under floor systems require , this ultimately dictates how the water is heated . And this primarily aspect can open a whole can of worms , so at this point I feel disinclined to venture into the world of heat pumps , and the for and against such technologies .

    @1A9lis@1A9lis4 ай бұрын
    • This system is so much more efficient than the old radiator. The TV room stat is currently set to 17 degrees and the temperature in there is 20. It was quite a difficult room to heat before, with it's tile floor sitting on dirt and then one rad.

      @CharlieDIYte@CharlieDIYte4 ай бұрын
    • Hi Charlie indeed your old system was far from perfect , and I’m sure this is the best solution for your remodelling . One thing I have noticed even on new builds , an approach that uses under floor heating on the ground floor then opting for radiators on the upstairs . Thanks for taking the time to reply . Kind regards as always 👍

      @1A9lis@1A9lis4 ай бұрын
  • No sound

    @tonydimaiolo3940@tonydimaiolo39404 ай бұрын
    • Not sure why. I'm got sound ... .

      @CharlieDIYte@CharlieDIYte4 ай бұрын
    • Turn the volume up

      @chrisohanlon69@chrisohanlon694 ай бұрын
  • U use way to many compression fittings

    @accesszero4803@accesszero48034 ай бұрын
  • Theres nothing good about them guns, i just use the thumb

    @accesszero4803@accesszero48034 ай бұрын
  • No sound on your video. ...

    @gul.iam.3195@gul.iam.31954 ай бұрын
    • Working fine for me

      @BinarySecond@BinarySecond4 ай бұрын
    • take the mute off

      @chrisohanlon69@chrisohanlon694 ай бұрын
KZhead