Powering An Old Mill - 1.5 Kw Lake District Overshot Waterwheel Project Part 3

2023 ж. 19 Қар.
529 467 Рет қаралды

In this episode we go back to the waterwheel and get some more jobs ticked off the list. However we still have alternator issues due to the alternator not being rated correctly. I contact the factory that makes them and they admit that they are not able to do the output advertised. So I am going to convert everything to work with a induction motor as generator

Пікірлер
  • Kris do not be too harsh on yourself! the whole wheel looks absolutely amazing.

    @AlexanderThoma@AlexanderThoma5 ай бұрын
    • Ya build a beautiful car and the engine you buy fails. This is a Patronizing comment, Typical of our time. Make sure ya send Kris his participation Trophy. Kris got F'd by China.

      @slougo5909@slougo59095 ай бұрын
    • some harshness is definitely warranted

      @ohlookatree_FPV@ohlookatree_FPV5 ай бұрын
    • you do great work. Lesson learned donr buy cheap chinese carp

      @Melicoy@Melicoy5 ай бұрын
    • When you see it on the menu it is so tempting.@@Melicoy

      @twotone3070@twotone30705 ай бұрын
    • Lesson learned: do not thrust Chinese labels or stickers 😂

      @BogdanDumiter@BogdanDumiter5 ай бұрын
  • I’m a 71 year old electrical engineer. One thing I learned (eventually) is that critical path items must be tested before being installed. It’s time consuming and costly to do so, but there really is no reasonable option.

    @Bellinghamimager@Bellinghamimager5 ай бұрын
    • IE: bench test the alternator under controlled conditions before taking it into the field?

      @Tailss1@Tailss15 ай бұрын
    • Yes. That would be my suggestion. 2kw is only about 3hp, so an electric motor of reasonable size could be used to drive the alternator. And a heater like the one he used could be the load. PITA, but could save a lot of driving and frustration. I really feel for this young fellow. He is such a careful, meticulous craftsman. Shame he god hoodwinked.

      @philterzian9162@philterzian91625 ай бұрын
    • @@philterzian9162 Speaking of the heater, I'm a little confused by that failure mode. It seems like a loss of mains is precisely when you'd want your 2kW off-grid water wheel running. Unless it's only supposed to kick in when the controller itself fails.

      @WolfePaws@WolfePaws5 ай бұрын
    • People should also have faith in ratings / spectifiations. China is just un truth full !!

      @jeffreywhite4962@jeffreywhite49625 ай бұрын
    • @@WolfePaws Good question Wolfe. I think he has a grid tied system of some sort. If the grid goes down you would not want to be tied to it for various reasons, phasing on restart for example. But it is puzzling. A water wheel charging a grid tied powerwall would be ideal I think.

      @philterzian9162@philterzian91625 ай бұрын
  • Kris, You measured a single wire. That is a three phase generator so there are at least 3 wires being used to carry the total 2KW power. You would need to cut open the splices inside where all the wires come together to connect to the outgoing feeds. There could be several parallel windings in the stator. Your cover to keep water off the gearbox and generator is also acting as a "hot box" holding all the heat inside. Louvers, vents and a fan might just be what you need.

    @randyb1890@randyb18905 ай бұрын
    • A fan on the alternator shaft would be a good idea

      @PaulG.x@PaulG.x5 ай бұрын
    • @@PaulG.x this. A passive fan and somewhere to direct the heat would solve the issue.

      @JaySilva88@JaySilva885 ай бұрын
    • Yes, that wiring can handle the theoretical maximum of 2KW ... in open air. It all depends on the cooling. So maybe easier to fix the cooling than redesign the system. Without a thermal model of the alternator in that housing there is no way to know what size it should be. @Kris There is this great supply of water right next to the alternator. Perfect for feeding some cooling pipes attached to the housing. ...

      @henkspaaij7961@henkspaaij79615 ай бұрын
    • Yeah, water cooling is a no brainer if there is a clog free way to achieve it@@henkspaaij7961

      @barthchris1@barthchris15 ай бұрын
    • Forget the fan, look at all that cold water. Just redirect some of that water to pour over the alternator and it will be nice and cool.

      @adamwilliams5426@adamwilliams54264 ай бұрын
  • Your 3 amp calculation is really per phase and you have 3 phases, so 9 amps seems realistic to me. You should also find out if the windings are star or delta connected. Resistance of wire varies and you won't get a good value by just considering the diameter. A better approach would be to measure the resistance of each phase then use P = V^2 / R

    @jonathanstubbs1387@jonathanstubbs13875 ай бұрын
    • Came here to say the same thing

      @headcloudmonkey@headcloudmonkey5 ай бұрын
    • And another thing.....a motor is an inductive load so the impedance is more complex than the resistive part.

      @jonathanstubbs1387@jonathanstubbs13875 ай бұрын
    • @jonathanstubbs1387; Are your referring to Delta or Y? (Wye) I have only heard of "Y" for generation over distance as in delivery across distance. ben/ michigan

      @benjamincresswell3713@benjamincresswell37135 ай бұрын
    • Yeah. From what I remember, a 3 phase motor can be wound as delta or Y (aka star). Just the same as a transformer for power transmission

      @jonathanstubbs1387@jonathanstubbs13875 ай бұрын
    • Remember your dealing with 3 phase. So you need to multiply by 1.732 to gain overall power (Root 3 in the 3 phase power equation). So P = V x I x 1.732 x PF (Power Factor).

      @johnclarke2997@johnclarke29975 ай бұрын
  • You are an eloquent testament to the theory that progress is made through an iterative process of failures leading to eventual success. Your consistent positive attitude and wonderful sense of humility are amazing. Keep going!

    @davidbudd2624@davidbudd26245 ай бұрын
    • I sure hope it stays this way, man it would be boring if we knew it all from the start lol.

      @s0m3th1n6s177y@s0m3th1n6s177y5 ай бұрын
    • NO david what Kris discovered is that iterative design is an expensive pain in the butt! (Just like SpaceX is discovering). The iterative design thing is a buzz word for putting off clients financial interests.

      @rcpmac@rcpmac5 ай бұрын
  • Nothing worse than having to explain to a customer that you’ve done everything to the best of your knowledge, and then to look like a fool because you’ve been lied to by a supplier. I really hope your customer understands and isn’t holding back on “too much” cash. This is what kills small business’, when all you want to do is have a happy customer who will spread your name, but go into the red because of nonsense like this. Head up mate! You’re doing a great job!

    @mrgazzoify@mrgazzoify5 ай бұрын
    • Absolutely 💯% nailed it! Kris has overspecced his top quality product so much the lying suppliers stuff becomes immediately obvious! - I *hope* the customer sees this as what it is and not what it isn't!! Your right, 5417 like this from "quick quid manufacturers" kills small pioneers and it's not fair!! Especially considering it also affects the manufacturers repeat business trade... 🤬🤬

      @TheRattyBiker@TheRattyBiker5 ай бұрын
    • Choosing suppliers is part of the job you are paid for. You are supposed to know what you sell to your customer.

      @niconico3907@niconico39075 ай бұрын
    • @@niconico3907 I 100% agree. But if I order a red car, and I’m supplied with an orange car that has been spray painted red, only for the red to peel off during installation, that is not my fault…of course I’ll never use that supplier again, but I do expect my customer to have some sympathy to the situation.

      @mrgazzoify@mrgazzoify5 ай бұрын
    • @@mrgazzoify it won't happen if you buy the car from a reputable manufacturer. If you buy it from a poor quality manufacturer you don't really know what you are going to get. It is also important to buy from a company with good after sale service.

      @niconico3907@niconico39075 ай бұрын
    • @@niconico3907 yes... 99% of the time what someone specs for a job is reliant on the data sheet provided by the manufacturer, he spec'd the job around what the client wanted {can't remember if this project was 220v at 1kw or 60v at 1kw} being that was what he read off the data sheet as an optimal performance (not maximum performance) it seems a reasonable assumption thar it would work.... If you buy a kettle you are told will boil water at 3kw you don't expect it to only hit 50 degrees at 250w max.... Or maybe more relatable a bearing rated to spin 4000rpm constant - 8000 max that constantly implode at 800rpm.... If they lie on the data sheet then how are you {the fitter} supposed to know any different unless you have had experience with that exact product before and know it's utter BS, what Kris does is bespoke and uses bespoke materials - how is he supposed to know any different when the data sheet lies? I'd like to see you take a custom spec sheet and hit the same and hit the nail on the head the 1st time...

      @TheRattyBiker@TheRattyBiker5 ай бұрын
  • Kris, have a rewind done on that motor in thicker wire to give you the 2.5 3kw that your needing. Sure it can be done by a rewind company in the UK and be cheaper then the cost of your time and materials on reworking the mounts.

    @ritchdoesit8433@ritchdoesit84335 ай бұрын
    • or rewind it your self

      @troopergoodwin6530@troopergoodwin65305 ай бұрын
    • Exactly what I suggested to him. It's his cheapest fix if he was pleased with everything else on the alternator.

      @LittleBozo@LittleBozo5 ай бұрын
    • Unless I misunderstood, I believe he addresses that the proper sized copper wire required is 3-times larger in diameter and would not even fit in the existing case requiring a replacement unit so much larger that it will not even mount on his existing bracket or under the covering hood without at least modification.

      @dougshomeshop3056@dougshomeshop30562 ай бұрын
    • To make it with a better quality wire and more windings and in effect would of saved the extra work in Part4

      @RTWParanormalUK@RTWParanormalUK2 ай бұрын
  • Kris, what a fantastic piece of engineering! Well done and meticulous executed. Before you start redesigning your generator setup however, please consider that this motor can actually do it, based on 3 phase and 0.7mm wire (as several people pointed out in the comments). However, when generating 2KW electricity and 80% efficiency it produces approx 500W of heat. This is the case regardless of the generator configuration. A redesign might improve the efficiency a bit but the heat still has to go somewhere. There are two ways to get rid of this heat: Convection and conduction. Convection transfers heat to the air around it and will require forced air flow. Conduction transfers the heat to the mounting bracket and the frame, from where convection will take over. Water cooling of the frame will reduce the convection needs, making this less dependent on the ambient temperature. A very rough estimate of convection cooling: If the maximum motor housing temperature is 60C and the ambient air is 40C (consider the summer) then there is a 20 degree max temp difference. Newtons law of cooling states that the rate of cooling is directly proportional to the temperature difference. If the surface area of the motor is fixed and the temp difference is fixed then your variable is the air flow. The heat transfer is calculated as: heat transferred (500 Watt) = hc (transfer coefficient) * A (surface area) * dT (20 degrees temp difference). 'A' is the motor surface area (which is enlarged by the ribs). hc depends on air flow speed and surface radiance. For air flow this is roughly 30 W/m^2*K for an air flow of 5m/sec and 40W for 20m/sec (so not linear!). If we ballpark the surface area at 1/10sqm then an air flow of 5m/s will transfer: 30 * 1/10 * 20 = 60 watt. You will need nearly 0.5M^2 surface area with 20m/s air flow to make this work for 20C temp difference. Disclaimer: this has some huge simplifications and should be properly calculated by a professional. Its been over 30 years since I last looked at this so no guarantees on the above. How to improve the air flow? Perhaps a fan blade on the generate pulley will do. It needs an opening in the housing where the fan can draw air inside. A big round hole in the cover in front of the fan would do nicely. This assumes that the air exit through the bottom isn't too obstructed. Probably best to combine this with conductive cooling using some of that water. Summers are getting hot and water stays cooler providing a greater temperature difference to work with. Conductive cooling has its own formulas based on transference of heat through a solid but this post is already long enough. I'd be happy to help bouncing off ideas if you like. Last, you can test this on your work bench by putting a 500W heating element in the motor cover and put a cowl over it. Then cut a hole and blow some air through and see the temp drop. Good luck and I hope your resolve it without too much headache.

    @henkspaaij7961@henkspaaij79615 ай бұрын
    • Nah, you'd have to directly cool the windings of the alternator. Blowing air or water over the frame won't increase it's capability much. Especially for a 100% duty cycle of what this is meant for. The windings are simply too small, and the unit's output is grossly over rated. It IS what it IS.

      @davelowets@davelowets2 ай бұрын
  • Sorry you have to deal with all that crap, but life is a learning experience. You do absolutely amazing work. ☮️

    @niles006@niles0065 ай бұрын
    • Refining and developement WILL BECOME THE ISSUE FOR THIS ENTERPRISES ' SUCCESS..LOOKING FORWARD TO MORE , EH..?

      @PeterLee-zn3jl@PeterLee-zn3jl5 ай бұрын
  • Hi Kris, I watched your video last night and I've been following your project. A few thoughts: First, if I was in your situation now, with the added pressure of this being a customer installation a couple of hundred miles up the M6, I'd be exploring the simplest solution first - and for me this would mean getting a PMG/motor manufacturer on board (I have a company in mind) that could help with either a new unit, or a rewind of one of those chinese units with a different winding configuration and possibly a replacement lamination stack. From my experience in PMG design, it looks like (and this is just based on how it appears on screen) that unit/design/size should be able to manage 2kW at ~90-95% efficiency if wound correctly. If you want to try going down this route, I can help you talk to these guys from a PMG design point of view, the first thing they'd need would be a whole host of measurements such as lamination stack depth, slot depth/width, airgap size, target RPM, etc. and with these numbers plugged into their software you should be able to get a quick answer on whether or not a rewind would be feasible. Regarding using an induction motor as a generator - whilst this can work, it's not as simple as a PMG because it needs an excitation voltage to generate, and if you do this with capacitors you will have to size everything for a single operating point/power point and then you have the problem of it being difficult to regulate, and possibly losing excitation and free-spinning. If I were going down this route, I'd be fearing 'opening up a can of worms' and I'd want to be fully testing and proving this in the workshop first, over the full operating range (using a motor-generator rig) before taking it on site. I've been involved in product developments in the past where the R&D spilled out onto a customers site, and for several weeks I was driving backwards and forwards to London every week trying to solve a motor control/stability problem that could've been solved at the lab, so I understand the stress involved. I don't know how to contact you other than this comment section, and after a couple of tries my comment seems to not exist if I leave any hint of my details. Cheers, Andy

    @user-xu5oe2fr1k@user-xu5oe2fr1k5 ай бұрын
    • The same came to my mind after watching the video... at this point it would be a reasonable option to look for a local provider, who knows the trade, speaks proper English and has business ethics.

      @szpl@szpl5 ай бұрын
    • Great comment - I agree about trying to rewind it yourself btw...

      @petercubbin@petercubbin5 ай бұрын
    • Alternatively, you should be able to find used alternators. Test it to see it works, then refurbish bearings and so forth if it does. There are also still some European companies that make big alternators. Kohler is one that pops to mind.

      @MrMarnix@MrMarnix5 ай бұрын
    • Andy, you might consider his email which I believe is a link in the site...I do agree with your professional assessment!

      @errolorticke5573@errolorticke55735 ай бұрын
    • @@szpl I am offering a new Baumuller Germany DSC100M64U10_8GDZ free of charge, shipping costs paid by swiss for a job similar to this one

      @udos46@udos464 ай бұрын
  • Yes, the Chinese cannot be trusted to be truthful in their advertising. I believe this is because of the fear that workers have of projecting facts which management doesn’t want to hear that would make the item more expensive to build. Management has an unrealistic expectation of an output, but the worker/engineer cannot this accomplish due to the reality of the science/physics behind it. It’s an insane system, which is why they have the reputation that they have. Another lesson learned, so now you move on to accommodating the materials that will make your project work. Love your work on everything you do!👍👍👍

    @joevalencic5275@joevalencic52755 ай бұрын
    • A chines never lie but dont tell the whole truth instead ;-)

      @henrikjorgensen1614@henrikjorgensen16142 ай бұрын
  • These videos lower my blood pressure. Not joking. Awesome and purposeful engineering plus the great outdoors. Love it!

    @NETBotic@NETBotic5 ай бұрын
    • I find them relaxing and have had my eyes closed just listening and fell asleep a couple times

      @aaronbutler5969@aaronbutler59695 ай бұрын
  • Live and learn. The work you've done is amazing. Don't kick yourself for the decision regarding the motor. Reasonable decision. Things happen. You've learned so much from the incident. You admitting the flaws makes you an honest man and sets you apart from the vast majority of people. Good on you! Keep it up Kris 💪

    @rasmuskurten8455@rasmuskurten84555 ай бұрын
    • The generator just needs airflow around it. The sheet metal splash hood 19:40 they built is trapping heat inside. If they attach a mechanical blower to the generator shaft, it will likely work fine at 2 kilowatt.

      @DMahalko@DMahalko5 ай бұрын
  • Chris take it to a local motor repair company they will rewind it to what you want. You will have confidence it will work.😊

    @kdenyer1@kdenyer15 ай бұрын
    • exactly what i was going to say cheers

      @davexvs@davexvs5 ай бұрын
    • ... yes, and let them use the gauge for 2kW - so there will be less windings and therefore less voltage - but Vi = di/dt, so when you get higher rpm, you can get 230-240V and you hav the possibilities with the gear/pulley.

      @ardufreak6973@ardufreak69735 ай бұрын
    • probably not enough space to fit thicker wire in as still need same number or turns.@@ardufreak6973

      @daviddawson9099@daviddawson90995 ай бұрын
    • It's not physically big enough to make that power no matter what you do with it.

      @lksf9820@lksf98205 ай бұрын
    • But the mettle housing simply isn't big enough to fit a winding that can produce a 2Kw output.

      @gillie-monger3394@gillie-monger33945 ай бұрын
  • I think you have to take a step back and just admire the whole projekt. This is absolutely stunning! Also huge props to the gully builder, that's looking really good!

    @matz4k@matz4k5 ай бұрын
  • Kris you are a one man business, developing an engineering product from scratch. .Don't lose heart, like you said you know how to fix this. You have created an amazing system and you have uncovered a product shortcoming very early in the process really.

    @ingridbrowne6083@ingridbrowne60835 ай бұрын
  • Hey Kris, the wheel is looking fantastic! some input for the electronics, if its of any addition to what you already know. The difference here is that they specify 2KW but this will be the short term Peak rating not the continuous rating. This is not that unusual to state peak rather than continuous, Chinese or otherwise. Motors, inverter, speaker, power amps always tend to use peak because people love big numbers. It also not just the wire, it is the power density/efficiency the wire you measured will be one of at least two for just one of the phases so current capability is ok (especially as the rating is KWpeak). Running a higher voltage from the motor for the same amount of power (lower current) will reduce the temperature rise in the wires/motor. Double the voltage/half the current but 1/4 the temperature rise of the Alternator. This is also more efficient to run at a higher VDC down the cable to your controller (of course short distance 30M or so this doesn't matter so much but every bit is a hit in over all system efficiency). If you get the output of the alternator to be in the top 1/3 or 1/4 of the operating voltage rating of the Solis DC input for peak RPM of the wheel. Also take advantage of some of the shaft rpm to shift air around inside that enclosure. Hope this helps.

    @chrisroberts2266@chrisroberts22665 ай бұрын
    • This... Read this a few times Kris.

      @ShainAndrews@ShainAndrews5 ай бұрын
    • Yes, this!

      @MasterStatusUK@MasterStatusUK5 ай бұрын
  • Your work is typically so well engineered and thought through; I can see how incredibly frustrating it would be to have faulty (lying) suppliers. Press on young man!

    @lurchor1734@lurchor17345 ай бұрын
  • Kris, great work, bummer about the alternator windings being under sized. One quick note, for 3 phase calculations, the formula for wattage is: P(W) = √3 × PF × I(A) × VL-L(V). P=power (in Watts), PF=Power Factor (you can assume 1 here), I=current (in Amps), VL-L=Volt, line to line (in Volts) this would be the voltage between phases. To "solve" for Current, the formula is I = P / √3 PF x VL-L Since the output is labeled as 220V, putting that into the formula gives you a current of 5.25A for an output of 2kW. Still more then that winding wire can handle. Hope that is able to help some of your calculations for wires sizes in the future.

    @thepeepsdotnet@thepeepsdotnet5 ай бұрын
    • While your correct, the 3a rating isn't right that's for an over simplified insulated cable so very far under what it can actually do

      @shaynegadsden@shaynegadsden5 ай бұрын
    • ​@@shaynegadsden Based on the video it looks like the alternator has 12 coils. This matches with a 4 pole alternator for 3 phase power and is in the ballpark of the used rpm. In this case there are 4 coils per phase in parallel, so the total current per phase with a 3A rated wire would be 12A per phase. So the alternater should be all right, because 2kW at 220V 3 phase is only 5.25A per phase. It looks like the problem is the load for the alternator. As far as I can see it, the alternater is connected to a bridge rectifier which is connected to the inverter (practically a big capacitor) without any power factor correction at all. This is the worst case. With a capacitiv or inductiv load on 3 phase power you get a phase shift between voltage and current (the power factor), but the current has still the shape of a sin-wave. With a rectifier and capacitor like Kris you get no current flow as long as the sinusoidal voltage from the alternator is below the capacitor voltage of the inverter. After the rises above the capacitor voltage of the inverter you get a huge current flow. This occurres twice per rotation and has to deliver all the power to the inverter. The problem is, that the wire (especially in the alternator) gets hot proportional the current squard by Ohmes law. So it is easily possible to produce 3 times the heat in the alternator with a "terrible" current waveform compared with a proper sinus waveform in e.g. a heater. This is the main reason, why power companies demand power factor corrections for practically all power supplies, because otherwise the mains cables would get much hotter (and the power companies had to pay for the extra heat generated). @Kris One way to solve your alternator problem is with a much bigger one to compensate for the excess heat production for the "terrible" waveform of the rectifier-inverter constellation. Another solution is to build in a power factor correction between the alternator and the inverter. Maybe a switch mode power supply from 3 phase to DC with a wide input range would do it, but I'm not shure. It depends on how the power supply would handle low input voltages an high output loads. Better power supply might simple turn off in the needed range of operation, cheaper ones might work.

      @Kubus-8472@Kubus-84725 ай бұрын
    • @@Kubus-8472 well the rectifier has no effect and grid connect inverter are just a big switch mode power supply , honestly none of it would have much effect the main issue is heat management there is no airflow and a cover keeping the heat in

      @shaynegadsden@shaynegadsden5 ай бұрын
  • Mistakes are a very normal part of any engineering project, don't be hard of yourself and keep innovating, the next iteration will be much better! P.S absolutely loving this series!

    @jackbannister-sutton4539@jackbannister-sutton45395 ай бұрын
  • Not only is this totally fascinating to follow, but your positive approach that learning is learning (& not 'failure') is really encouraging and inspiring.

    @emmaslow@emmaslow5 ай бұрын
  • 34:47 The label alone provides for mistrust in the alternator's ability. Otherwise, your work on the wheel, all things mechanical and your commitment to a job well done is inspirational!

    @scratchinjack608@scratchinjack6085 ай бұрын
    • What about the label gives you mistrust?

      @SageThyme23@SageThyme235 ай бұрын
    • @@SageThyme23 the label says 2kW @ 500 rpm...

      @Coyotehello@Coyotehello5 ай бұрын
    • In my experience, divide chinese amp ratings by 1.7 to get close to the real capacity.

      @MazeFrame@MazeFrame5 ай бұрын
  • Keep learning kid, and your tenacity is admired. Lots of help around from the old school for those willing to ask.

    @martinjustice@martinjustice5 ай бұрын
  • I know it's frustrating Kris, but we are learning from you. Your equipment is fine, but now we know what to look out for from the other manufactures. I expect next week we will learn even more. Thank you for handling it so well. I hope this next week is better for you.

    @anitamitchell3452@anitamitchell34525 ай бұрын
  • As. Classic race car engineer, I’m really addicted to this channel it’s great to hear a guy with this amount of knowledge on the case

    @brucerawsthorne1338@brucerawsthorne13385 ай бұрын
  • You have inspired me to leave London after 18 years and return to the valleys of Wales to get involved in forestry projects. Just need to find a job and a house now!

    @seanjamescameron@seanjamescameron5 ай бұрын
  • Super impressed with the change from the new nozzle/flu. Great job

    @billleiker5314@billleiker53145 ай бұрын
  • Great video, I used to work for a world renowned hydroelectric turbine company from the lakes, and travelled all over the world doing installs and the number of times we would come across projects with Chinese hardware and the customer would tell us that it wouldn t produce what they stated was crazy, also kit would fail very quickly due to inferior materials used. Take it as a lesson learnt and carry on with your great projects, your doing great

    @biglad555@biglad5555 ай бұрын
  • Wow! No one could have anticipated this kind of fraud. I'm floored. Chris, you are doing the entire community a real service!

    @jimgriffiths9071@jimgriffiths90715 ай бұрын
    • The alternators do produce 2kW, only 600w is electricity, the rest is heat. Not really what is expected though.

      @cheeto4493@cheeto44935 ай бұрын
    • @@cheeto4493also duty cycle and surge rating matters a lot. Inverters are bad for that too.

      @dmacpher@dmacpher5 ай бұрын
    • Everyone who has previously dealt with Chain: 'Yes, we could expect this type of fraud!'.

      @godalmighty83@godalmighty835 ай бұрын
    • In the USA, some companies rate the horsepower of their vacuum cleaners, air compressors, etc. by multiplying the startup current by the voltage! So you get a surge start number as your "horsepower", which is usually about 2.5 times the running power.

      @UncleKennysPlace@UncleKennysPlace5 ай бұрын
    • This is exactly what people buying wind generation equipment are finding as well. The promoted generation numbers are often 10X of the true capabilities .

      @keithjacobson4493@keithjacobson44935 ай бұрын
  • I can totally understand the frustration. But you are very thorough and smart enough to find a solution, which is why I love watching the channel. Good luck on this one Kris !👍👍

    @BlueSpark-vy3fd@BlueSpark-vy3fd5 ай бұрын
  • For 3 phase generators and motors the current per winding is not Power/voltage; it is (power/voltage)/( square root of 3). The square root of 3 is 1.732, so your 9 amps is actually 5.2 amps. Also you will find there are many windings of the small wire connected to the 3 main wires so the current is divided between these wires. When many wires are crammed into a tight space the current carrying capacity (due to temperature) is greatly reduced. I have found that the ratings of electrical products that are made in China are usually exaggerated. Best of luck with your great project.

    @Jimscoolstuff@Jimscoolstuff5 ай бұрын
    • The plate says that It’s rated for 220V not 415V. It’s single phase.

      @MrSimonious@MrSimonious3 ай бұрын
    • At 6:30 into the video, He shows the 3 phase rectifier and points to where the 3 phase wires enter the control box. Three phase motors and generators can be made for any desired voltage.@@MrSimonious

      @Jimscoolstuff@Jimscoolstuff3 ай бұрын
  • Very talented engineering here, great to see. You will get it working fine and then the alternators can be used for another project. Great to watch!

    @hiltopuk@hiltopuk5 ай бұрын
  • Kris, kudos to you for exposing the lies as you did. I can only imagine your frustration, but everyone who watches this channel knows you will more than make everything right in the end for your client. That water wheel is a work of art. And once done, I am certain it will run for years.

    @codemonkey2k5@codemonkey2k55 ай бұрын
  • If the ampacity of the winding is ~3A, that is 3A per phase, which should give you ~9A combined. It would be interesting to see if the wire is in fact copper. I would guess that somewhere along the line the copper specified in the design has been substituted for copper-coated-aluminium which has a much lower ampacity as well as a lower service temperature. It might make sense to explore re-winding it yourself. Best of luck.

    @gardner959@gardner9595 ай бұрын
    • If I remember my schoolboy physics of many decades ago, Assuming the alternator is a delta winding, I don't think it would be 9 anps, the line current is not 3 times the phase current, it's the square root of 3 (1.73) multiplied the line current which would be 5.2 Amps I've probably got it wrong, but I'm sure someone will correct me if it is haha

      @petejones1957@petejones19575 ай бұрын
    • It could also be a thicker insulation coating than designed for..

      @kschleic9053@kschleic90535 ай бұрын
    • @@petejones1957 Correct. Getting a balanced 9A line current from a delta connected generator means a winding current of 5.22A. And in a wye connected generator means that line current is winding current.

      @randacnam7321@randacnam73215 ай бұрын
    • @@TheJfast2surely there is more than one pole per phase on the generator? I’m curious about the Solis inverter. From a quick scan on the internet, it seems the inverter is a PV MPPT inverter which won’t be suitable for a PMA. It would need a controller with a calibrated power curve as do wind turbines.

      @kevinmills5293@kevinmills52935 ай бұрын
    • @@TheJfast2 The consideration that also has to be made is the gross efficiency loss of running an alternator that is generating so much heat. That energy being dissipated as heat is kWh that the wheel is generating and the customer is not seeing in their electrical generation. Running it long term would make a mockery of the work Kris has done to design an efficient wheel, even if it is capable of making more than the 2kWe he has designed it for. Chances are it would bake the lacquer on the windings and short internally fairly quickly, especially with loose winding wire hanging around in there. As unfortunate as it is, I think Kris is on the right path with either an induction motor or finding a more reputable alternator supplier.

      @jncg2311@jncg23115 ай бұрын
  • You're such an inspiration Kris....on so many levels. Your creativity combined with engineering reminds me of Leonardo De Vinci on a smaller scale. I bet he never had to deal with a bunch of patent stealing, peasants that can't spell the word quality! Time for a beer, hot bath, good nights kip then soldier on with the revision to the original design. As Robert Pirsig so wisely observed in Zen and the Art of Motorcycle Maintenance, if you don't overcome the "gumption trap" that this has created for you, you'll just engineer your bad mood into the next phase. Keep on old son, you're soooooo on the right track.

    @Byoomholay@Byoomholay5 ай бұрын
  • Really valuable information . You help so many people with sharing this lesson. I would of made this the same mistake.

    @jameswhite6031@jameswhite6031Ай бұрын
  • Looking around the UK for alternators, they are expensive (compared to Chinese) but the rating will be 100% guaranteed. I found one called the "stamford" in single or 3 phase outputs. They are also pretty heavy...like 75kg!

    @JohnnyMotel99@JohnnyMotel995 ай бұрын
    • This does suggest that a larger chinese one, multiplying it by the chinese bullshit factor to get the right size, is still going to be the best deal.

      @herseem@herseem5 ай бұрын
    • @@herseem Not if the only thing different on the "larger" chinese one is the sticker...

      @69Buddha@69Buddha5 ай бұрын
    • ​@@herseem Indeed. Chinese factories DO make good stuff, but I've found they struggle with honesty. Most companies looking to offshore manufacturing to China end up posting their own QC team inside of the factory. They have to keep tabs on them, or they'll start cutting corners without telling you. I'm sure there are Chinese manufacturers that don't do this, but the general reputation for the nation has been sadly earned. If you're willing to sort through the sea of cheap crap, there is some excellent stuff made over there.

      @WhyBeNick@WhyBeNick5 ай бұрын
    • @@WhyBeNick your experiences mirror mine

      @herseem@herseem5 ай бұрын
  • You are helping a lot of people avoiding frustrations with this video! Think about it, I bet you will feel a bit better! One solution could be to rise the rpm (Higher voltage means lower currents). For this you have to make sure the wire isolation is rated for the higher voltage and also the maximum input voltage of the inverter. (The inverter input voltage could be fixed with an transformator before the rectifier, its another thing you have to add but maybe worth if you have to change the whole design instead...). Hope the ideas help!

    @Totial@Totial5 ай бұрын
    • I wanted to make the same suggestion . When you double the speed the voltage also doubles. The iron losses will also double. But I think the losses of the current are much higher. I am wondering if the currents in the generator are sinusoidal. Is there a bride rectifier?

      @janhummel9748@janhummel97485 ай бұрын
    • The 220v on the label is also very confusing. Does it mean the rectified voltage, the phase to ground voltage or the phase to phase voltage. Normally there are two numbers one for phase to ground and phase to phase.

      @janhummel9748@janhummel97485 ай бұрын
    • Personally I don’t think it will help. It the power that is generating the heat not just the current. Up the voltage and drop the current the power (kw) is the same

      @johnwarwick4105@johnwarwick41055 ай бұрын
    • ​​@@johnwarwick4105 the current is doing the losses not the voltage or the power

      @janhummel9748@janhummel97485 ай бұрын
    • @@johnwarwick4105 its the current what generates the heat, not the power! (Actually the friction of the moving electrons trough the metal wire)

      @Totial@Totial5 ай бұрын
  • A wonderful reminder of yesteryear and the grain mills that changed the world. Your work is beautiful and practical. Looking forward to the improved model.

    @normanroaten9132@normanroaten91325 ай бұрын
  • I admire your tenacity. Keep at it, document your lessons learned, and carry on!

    @ChristianMercadoAcevedo@ChristianMercadoAcevedo5 ай бұрын
  • Quick tip; When modifying the generator guard, add some strategically placed venting holes. These generators, and especially synchronous motors rely on open air to properly cool. That might fix the overheating issue.

    @tipetu@tipetu5 ай бұрын
    • I thought attaching a radial vane fan to the drive pully inside the housing would turn the housing into a squirrel cage fan of sorts and remove that heat island effect around the alternator.

      @chuckliles4071@chuckliles40715 ай бұрын
    • Venting holes pose a risk of water ingress. On the other hand, since there is plenty of cool flowing water at hand, a good thermal connection to the housing might be a good idea, then a little water could be diverted to cool the housing.

      @surfcello@surfcello5 ай бұрын
    • I would add fan blades to the pulley to aid in cooling

      @mikedengel4027@mikedengel40275 ай бұрын
    • Still not going to be enough. That chart he showed is about gauge of wire and carrying capacity with it's known resistance and the thermals that will generate. Sure you might cool it down a couple degrees, but that chart is basic physics and there's no way you're going to get from 650 W to 1.5 kW. Those wires will fry long before that :(

      @michaeljaques77@michaeljaques775 ай бұрын
    • why dont he use copper pipes warped around the generator and same water to take away the heat to get atleast 20 percent more power output comfortably

      @ali2naveed@ali2naveed5 ай бұрын
  • You're like an industrial detective. Sherlock Harbour. Love it!

    @iaintodd9374@iaintodd93745 ай бұрын
  • Look how far you’ve come, this is a tiny blip on your amazing journey of experience! You’re fantastic and inspiring as always, cheers Rob.

    @Bothtapes@Bothtapes5 ай бұрын
  • Very impressive work that. First of many future installations I’ll wager. Your path to excellence is very rewarding to witness. That waterwheel is pretty much perfection in motion. Great stuff.

    @MrDoyley35@MrDoyley355 ай бұрын
  • I think it can do 2kw when run at double or even triple the speed you were running it at before. A modified car alternator will do 2-3 kw continuous with less copper than this one. Forget what the tag says about rated rpm and what not, you just need to make sure the voltage doesnt exceed whatever that grid inverter is capable of. You already kinda hinted at this in the last video where the water wheel was spinning too fast but the alternator wasnt overheating.

    @noonespecial9131@noonespecial91315 ай бұрын
  • Very frustrating 🙁 Fair play to you for having the skills and knowledge to work it out 👍🏻 Good luck with rectifying all the issues 🍀

    @Craig-MItchell@Craig-MItchell5 ай бұрын
  • So love the methodical testing. Really nice to watch and learn!

    @samuelgeorge8524@samuelgeorge8524Ай бұрын
  • Lessons learned are always the biggest expense of any job. Really enjoy your videos Kris thanks for sharing

    @madspider247@madspider2475 ай бұрын
  • 3 amps in that size wire is a pretty conservative rating, you can get very high temperature enamel (>200C) and the insulation cooking is the real limiting factor. The chart you flashed up is talking about domestic wiring in PVC, totally different kettle of fish (melts at ~80C)

    @maxhammick948@maxhammick9485 ай бұрын
    • Exactly this, take a look at the windings in any transformer found in domestic appliance. i.e. microwave. They are very thin, and it's just fine

      @anonanon5878@anonanon58785 ай бұрын
    • But he literally tested it and it was getting unreasonably hot well before the rated output. Obviously something isn’t up to snuff there.

      @brianpennington4202@brianpennington42025 ай бұрын
    • High temperatures are a bad idea for a whole raft of reasons. Higher energy at lower current requires more voltage. More voltage needs higher shaft speed. That alternator is a non starter, the dreadfull winding quality is totally unsuited to high voltage.

      @rodbicke@rodbicke5 ай бұрын
    • @@brianpennington4202 Yes, shouldn’t the generator be actively cooled?

      @Brasilianer1@Brasilianer15 ай бұрын
    • @@brianpennington4202 Enamelled wire isn't needed on something that doesn't get up to 80C. They're designed to run hot, this isn't a laptop that needs to be safe to touch

      @maxhammick948@maxhammick9485 ай бұрын
  • A good honest episode. A lesson learnt. If you find a suitable replacement, you could use the lathe as a test bed, having made a fixture for it.

    @craigbrown2183@craigbrown21835 ай бұрын
  • I do enjoy your updates on this project. I’ll be waiting for your next updates.❤

    @Jameson4327@Jameson43275 ай бұрын
  • it is so good that someone that knows what he is talking about . keep it up.

    @malcolmgodden1732@malcolmgodden17322 ай бұрын
  • Your work is brilliant Kris, and this issue relates directly to basic dishonesty on the supplier's behalf, a problem I have run into time after time with Chinese suppliers unfortunately.

    @keithglaysher9201@keithglaysher92015 ай бұрын
  • I feel like in the grid outage scenario, you'd be better off with some form of solenoid released trapdoor in the channel which just releases causing all the water to be discharged before the water wheel, stopping the wheel. I feel like trying to use the dump resistor is just a real risk on many levels - if any component fails (which is quite probable in a rarely used emergency system), then there are quite a few different failure modes, some more spectacular than others. But above all else, assuming that dump resistor goes straight across the generator output, you're likely to get very low voltage and high current, potentially leading to the generator overheating issues you've already seen. The other option would a brake that brings the wheel to a controlled stop, but a trap door in the channel feels like the easiest solution, even if it requires a manual reset afterwards.

    @gwendragon6419@gwendragon64195 ай бұрын
    • That or something that unwinds itself and just closes a dam to the waterwheel / opens the route to the bypass. I was thinking the same thing,

      @thomasvnl@thomasvnl5 ай бұрын
    • @@thomasvnlTrapdoor seems more failure tolerant. Any mechanical movement of the dam could be blocked by twigs, branches, etc.

      @paulreinhardt6052@paulreinhardt60525 ай бұрын
    • @@paulreinhardt6052 gravity or momentum assisted movement might be a viable option though. Like keeping something closed unless power is released and therefore releasing like a spring to unwind and turn a lever/dam door. Something the likes of that comes to my mind. Of course, this would have to be refined but turning mechanical energy into a heater outdoor just seems silly to me (although I get why as it seems a very easy solution). But the issue Kris had already with the sudden torque after power was restored and the wheel was unloaded from the burden resistor shows this easy method needs refining as well.

      @thomasvnl@thomasvnl5 ай бұрын
    • @@thomasvnl I know nothing about this specifically, but I can’t imagine many many people haven’t already figured something out. Perhaps heater is a standard solution. Idk. 🤷🏻‍♂️

      @paulreinhardt6052@paulreinhardt60525 ай бұрын
    • Or a grid solenoid controlled brake on the wheel.

      @familyoffourdisneydreaming6081@familyoffourdisneydreaming60815 ай бұрын
  • The old saying Buy cheap buy twice comes to mind ! Hope you get it sorted Kris

    @MrMush78@MrMush785 ай бұрын
  • Problems arise now and then, but you persevere so good on you. I have enjoyed this series, thanks for filming it Kris

    @andrewluger7133@andrewluger71335 ай бұрын
  • might be an interesting project to have an automated sluice gate controlled by the frequency from the alternator to "tune" the waterflow to maximum efficency.

    @grahameida7163@grahameida71635 ай бұрын
    • My thoughts as well. Actuator that could control flow

      @ethankincaid9022@ethankincaid90225 ай бұрын
    • It would need to be well designed so if anything fails, anywhere, the sluice closes.

      @richardschofield2201@richardschofield22015 ай бұрын
    • How about using a gate valve like they do in refineries..That is powered by electric 😊😊😊

      @bradfordthompson8326@bradfordthompson83265 ай бұрын
    • No need for complicated system, a purely mechanical system can do it. A floating buoy on an arm can open and close the overflow sluice gate to keep the water at the right level behind the dam. If the level is constant, the flow on the wheel will be constant.

      @niconico3907@niconico39075 ай бұрын
    • @@niconico3907 how would the float know the load on the alternator. If there's no load you need less water so the system needs to be triggered by wheel speed not water level

      @richardschofield2201@richardschofield22015 ай бұрын
  • Would be great if a UK-based alternator manufacturer might see this and get involved! I guess on the "bright" side you have a spare 600w alternator and a heater that might work on future projects. Thanks for doing the hard, painful work to inform us all of such pitfalls. And, despite a setback here and there, I continue to have: No. Doubt. In my mind.

    @CharlesKiblinger@CharlesKiblinger5 ай бұрын
    • Yea I was thinking for non-critical home projects without a customer. But most important, the UK-based alternator manufacturers need to take notice! @@BreatheScotland

      @CharlesKiblinger@CharlesKiblinger5 ай бұрын
    • @@CharlesKiblinger - I thought ALL manufacturing was done in China or India.

      @jrstf@jrstf5 ай бұрын
    • @@cmmartti - No disagreement. I have received many working devices from China, I have never received a NiMH battery from China that comes anywhere near spec, same for flashlight intensities, and I've tried many.

      @jrstf@jrstf5 ай бұрын
    • A desultory google search turned up "Stamford | AvK." But I bet the prices ain't the same.... :) @@jrstf

      @CharlesKiblinger@CharlesKiblinger5 ай бұрын
  • Love these hydro power videos and why I originally came to the channel. I think what you are experiencing is super normal when you rely on subcontractors. Keep up the good work.

    @CR-di1lg@CR-di1lg5 ай бұрын
  • Good on you for bringing some honest and interesting content to youtube! I'm also surprised by what the different manufacturers admitted to in emails.

    @user-xf1rb7on2j@user-xf1rb7on2j5 ай бұрын
  • All is not lost. Thank you for putting in the time on this. The world is a better place for it! Cheers! Keep on keeping on.🥃

    @jamesgreene8629@jamesgreene86295 ай бұрын
  • That's some pretty amazing troubleshooting skills you've got there. Clearly, they don't expect people to figure out they've been cheated. I bet you could make one of those alternators put it on the market and give those lying cheats a run for their money. That was a costly lesson. Yikes. I have faith you'll get it all sorted out.

    @lucillekenney8311@lucillekenney83115 ай бұрын
    • Kris' 12 bore shotgun alternators should be a thing 😂😂😂 referring to 12 gauge windings to keep that thing running at full kaboom with minimal heat loss 👍

      @TheRattyBiker@TheRattyBiker5 ай бұрын
  • In a 3 phase generator the power is split between the phases. Each phase delivers 1/3 of the power. Your calc for wire size should be 666 watts at 220v is 3 amps. In cars there is often a fan on the alternator shaft to keep the alternator cool. You might be able to fit a second alternator on one belt to spread the load but you'll need to rectify that separately and put the two rectifier outputs in parallel. This is the most professional water wheel I've seen in modern times. Looks beautiful.

    @senorjp21@senorjp215 ай бұрын
    • Indeed, however that 3 amp rating is for open air wires, not bundled. This constraint is briefly shown at the top of the chart on the phone. How much the actual amperage is depends on the thermal configuration of the alternator. Given enough cooling this alternator could work as specified, so the 'theoretical maximum' is actually correct. Rather than redesigning the whole system, which seems a rather massive task, maybe a water based cooling system would be easier. Impressive setup and very well done. I hope you get things sorted out.

      @henkspaaij7961@henkspaaij79615 ай бұрын
    • Wattage delivered from a 3 phase generator is calculated using the square root of 3 if you know the phase current. W=1.73 x phase current x voltage x power factor. :)

      @JOHNTHE8TH1@JOHNTHE8TH15 ай бұрын
    • @@JOHNTHE8TH1 Is that true when the phases are rectified to DC? I thought that was for a 3 phase load where the phases are connected in a wye. With a rectifier AC doesn't flow between phases - the load doesn't see peak-to-peak voltage between phases

      @senorjp21@senorjp215 ай бұрын
    • @@senorjp21 think of it this way. only the phase with the highest voltage will conduct to the dc circuit through the rectifying diodes. the phase may still be on the positive side of the cycle but it will stop conducting once another phase takes over, so most of the sine wave of each phase isn’t used and the power transferred cannot be a straight multiplication by 3.

      @JOHNTHE8TH1@JOHNTHE8TH14 ай бұрын
  • Just come across your channel you have created a wonderful life it seems. My family and I are preparing to move to Alaska ourselves to have a better life. We are in North Carolina as of now. We will continue watching your journey. Awesome content

    @TheRoseFamilyVlog@TheRoseFamilyVlog4 ай бұрын
  • You may already have experienced this: every redo always turns out better. The school of doing is one hell of a teacher! Clear your mind and go at this anew, as if it is new … because it is new, again and so is the day.! 👍 You are mastering this as you go; just don’t be dangerous.

    @JF-fx2qv@JF-fx2qv5 ай бұрын
  • Kris, problem solving is what you do - I have every confidence that you’ll sort it! Also lots of great advice from the electromotive geeks and engineers in the comments. There’s some gems in there I’m sure.

    @darwinsfish@darwinsfish5 ай бұрын
  • I loved the detective work of the wire etc.

    @edbrackin@edbrackin2 ай бұрын
  • Hi,Kris. I had a lot of involvement with a water wheel/alternator installation at an old mill building. My part in the project was making many mechanical parts to get the pulleys ,shafts,pillow blocks and all the belt tension adjusters etc for the toothed belts. The installation I worked on used wind turbine 'pancake' style alternators with the wind turbine blades removed and a custom taper lock hub fitted to mount toothed pulleys instead of the wind blades. This system is 3 phase with 3 alternators all being driven by the same countershaft and each alternator being switchable for in or out of the system depending on how much water flow is available at the time. You might have some joy by looking at what 'pancake' wind turbine alternators may fit into your limited space at the drive end.

    @howardosborne8647@howardosborne86475 ай бұрын
  • Well done my friend you have a great knowledge so don't beat yourself up you have done a excellent job in your work and your diagnosis take care and well done regards Alan and Ella.

    @alanmcclusky@alanmcclusky5 ай бұрын
  • "Look at that angle.... perfect" I know too well the pride that comes from something that goes as you hope, but that has generated so much anxiety... Really top work!!

    @ukrspp21@ukrspp215 ай бұрын
  • Just a thought on the dump load / heater. The problem isn't the power wattage, you need the 2 kW in the end to burn off the power of the water wheel. The problem is the instant torque difference at the moment of switching from grid to the heater. You could solve this with an additional 500W heater and a timer relay. The first, let say 5 seconds of grid down, the power goes only to the 500W heater. Because it's smaller you don't get that torque shock. After 5 seconds, the timer relay adds the original 2000W heater to the load, making it 2500W. Great project, I keep following it. 👍

    @Guust_Flater@Guust_Flater4 ай бұрын
  • Your talent is truly impressive! You should be proud of yourself and not dwell too much on any perceived imperfections. From my perspective, the whole wheel looks absolutely amazing! Keep up the great work!

    @aaronbirchnall6840@aaronbirchnall68405 ай бұрын
  • Great video Kris. Too bad that you had this issue but it is totally inspiring that you keep going and do whatever it takes to get it right. I cannot wait for the next video. And furthermore I think these videos should be shown in schools because you are one hell of a guy who is prepared to have a go at anything and do it really well.

    @daedalusjones3804@daedalusjones38045 ай бұрын
  • thanks for the video, I was talking with someone about this process of power generation 2 days ago, and you have just taught me so much in a single 40 minute video. Lots of food for thought here.

    @myworld8266@myworld82665 ай бұрын
  • Not your fault, the time and effort that you put into your progects is always worth the reward.

    @myface694@myface6945 ай бұрын
  • Really interesting watch, have had the same issue with inverters in my camper. Keep on going 👍

    @eanticsltd@eanticsltd5 ай бұрын
  • I know how frustrating this has been for you - but seeing you dismantle their BS so succinctly was immensely satisfying and I'm glad they've been outed - these types of things drive me MAD and I love it when they get their comeuppance

    @zedooncadhz@zedooncadhz5 ай бұрын
  • It's cool to see how your skills and shop/homestead have progressed over the years, I've been binge watching your Playlist over the last month. Thanks for all the inspiration and great vids.

    @srtautoworkz@srtautoworkz5 ай бұрын
  • Ah man, what a pain! These things are sent to test us sometimes! Great job mate! Stick with it! All the best.

    @danielcope7929@danielcope79295 ай бұрын
  • Most online sales are not to be trusted, and I really hope you get it all sorted out. I really like the whole waterwheel power projects, so it would be very nice to see it fully working at max power without getting too hot or break.

    @taleg1@taleg15 ай бұрын
  • Kris, it takes a man to show humility, and its what you've done in this video. Love watching your videos, and we're all human, things happen.

    @dudemaestromaster@dudemaestromaster5 ай бұрын
  • That is horrible. I have no doubt that you have proven to your customers your effort, reliability and quality are not to blame for this issue. Really really sucks to think that you're almost done and then have it get screwed up like this. Super proud of the work you do even if you aren't always. :)

    @Moriandrizzt@Moriandrizzt5 ай бұрын
  • Genuinely gutted for you, I really felt your frustration knowing how close you are to the end of this project. Damn!

    @hawkmoon1704@hawkmoon17045 ай бұрын
  • Keep your head up Kris, I’m sure it will all come good. You’ve put a lot of hard work in so far, tackled many teething issues, made improvements, and so one day soon you will have everything running as planned and will have learned many valuable lessons along the way, which is what life is all about. Further, your product will be better refined for the next customer. Looking forward to your next video!

    @Connor51440@Connor514405 ай бұрын
  • I get that you probably need to move it occasionally for clearance, but i can only imagine how much easier that sheet metal roller would be to use if it was semi-permanently fixed down.

    @Stu_2112@Stu_21125 ай бұрын
    • May I suggest braked castors

      @charlesroberts5637@charlesroberts56375 ай бұрын
    • Or could it be motorised - hopefully a bit simplified than water wheel project

      @laughing_inside@laughing_inside5 ай бұрын
  • That's why critical electrical components must be either from reputable sources or tested prior to installation. I'm so sorry I couldn't see the finished water wheel generator but, I'm delighted that you are going in such depth to inform everybody to all the inner works of such interesting and realistic projects.

    @Daemorien@Daemorien5 ай бұрын
  • This is absolutely amazing Kris, I'm so inspired!

    @metronohm808_6@metronohm808_65 ай бұрын
  • Fascinating project! I'm sure you'll get this system running in perfect harmony despite the setbacks. It's a bit of a sad world we live in today when you can't trust manufacturers/sellers to be anywhere near their advertised ratings. 10 or even 20% less might be acceptable, but 60% less than rated is bananas!

    @sirgreybat5954@sirgreybat59545 ай бұрын
  • WOW! I'M SUPER IMPRESSED WITH THE SHOOT SPLASH IMPROVEMENT! AMAZING ENGINEERING!

    @my_permaculture@my_permaculture5 ай бұрын
  • They often make the windings using several thiner wires in parallel rather than single thick ones. Not only it is easier to manufacture but in fact it has some advantages too because windings fill the gap in the core better. But the problem is it has to be properly connected to terminals which is not always the case.

    @Zortorond@Zortorond5 ай бұрын
  • I love this series and particularly that you name and shame the charlatans who are mis-selling wares. They need exposing for the liars that they are. After being sold crap like this myself, I'll never again buy from Aliexpress. They would not accept a return from me even though it was not the goods i had ordered. Otherwise... this series is absolute gold Kris. I'm inspired by your work and I've started building a wind turbine to supplement my solar.

    @NigelMarston@NigelMarston5 ай бұрын
  • Great video...tell it like it is...thats the secret of good youtube content. We enjoyed your project solving energy and taking us through each stage with all the problems and your solutions is really marvellous content.

    @timshimmin3468@timshimmin34685 ай бұрын
  • Absolutely amazing, wish I was involved in a project like this! One slight little improvement on the “Grid down” circuit is to add an indicator light.

    @RogierYou@RogierYou5 ай бұрын
  • Hi Chris , I enjoy all of your videos. On this actual video, you are frustrated because of the poor performance. As a retired elctrical ingeneer from Denmark,I could suggest you to contact a electro mechanic and ask Them if it is possible to get rid of the poor windings and put in new coils with insulation that are rated for very High temperatures. Class F is rated for 130˚C if I recall it right. It is possible to apply new windings in the original motor with a vacuum resin treatment that gives extra improved cooling. You could consider applying a kind of external cooling (I mean you have coolingwater at hand😎) God luck and best wishes.

    @larsleanderlaursen6786@larsleanderlaursen67865 ай бұрын
  • If you ever have need of cooling something in the presence of water I would have a look into heat pipes. Have a search for thermosiphon. If you were to get some thin copper pipe and wrap some windings around the alternator, the water(or antifreeze) will warm from direct contact and/or IR, the other side of the loop would be made cold by the river, or water exiting the waterwheel, I love it because the temperature differential circulates the fluid in the sealed loop, the only moving part is the fill plug. I suppose you could use brake line as well if its easier to work with or cheaper.

    @chemicalvamp@chemicalvamp5 ай бұрын
  • I'm sad about the device not matching to specifications. Amazing how you were able to get them to admit it in the end. You were sold nothing but a bald-faced lie. In the meantime, the 316 stainless nozzle was a work of art and thing of great beauty in action. Bravo! Keep up the great work!

    @waiakalulu7544@waiakalulu75445 ай бұрын
  • I really feel your frustration Kris. I've bought some items from China that were great but also quite a few that were fit for nothing other than use as doorstops. Like you said so often in the video, it's the dishonesty of the sellers that get's me every time.

    @daveturnbull7221@daveturnbull72215 ай бұрын
    • Not just sellers but also manufacturers. A common practice in China is to use the same factory for making wildly different quality runs of the same product. Some generators use proper grain oriented silicon steel and copper magnet wire; others use scrap leaf springs and zinc (yes, really) magnet wire. They even have a saying: 能骗就骗 (Néng piàn jiù piàn; If you can cheat, cheat).

      @randacnam7321@randacnam73215 ай бұрын
  • I like this waterwheel content. I saw your channel years ago and saw you in a wood branch roof workshop, but you have come so far since then with your designs and waterwheel durability. I encourage you to go with the best parts for the money and raise your prices. Your craftmansship is worth it. Just consider this instalation and working out the bugs and suppliers as your final proof of concept before you make a webstore and showcase what you can do. (p.s.) you should shave down that keyhole part that was sticking out a tiny bit. Always take care of potential problems in the shop and eliminate any future things that "could" happen Its just better peace of mind to machine that down a millimeter. Doing all these little things will warrant your increase in prices. Its looks fabulous.

    @wbass243@wbass2435 ай бұрын
  • Looks good. Don't forget when it rains there will be more flow. Summer time will also add an extra 30 degrees to that alternator.

    @user-ht2tc8de1m@user-ht2tc8de1m5 ай бұрын
  • Great investigative work on the generators!

    @expierreiment@expierreiment5 ай бұрын
KZhead