OBSERVATION CODES FOR EICR - ELECTRICAL INSPECTION AND TEST - THE RIGHT CODE AT THE RIGHT TIME

2023 ж. 13 Қаз.
5 837 Рет қаралды

This video is a short introduction to recording observation codes on EICRs correctly. What code to use is very much up to the individual inspector who is on-the-spot, so to speak. And many inspectors will need little assistance to coding correctly. But what if you are just beginning your journey into the world of inspection and test - this video will help.
Recently we’ve had a few requests to make a simple introduction into choosing the correct observation codes along with questions like …
Is there an easy way to distinguish between a C1 and a C2? And when should a C3 be used.
So this video will keep things simple. There will be a couple of tips on how I look at the different codes and these will help you to understand the logic behind the codes.
One question that often pops up goes like this …
If the installation was installed to a previous edition of the Wiring Regulations, and possibly showing evidence of additions made to earlier editions, which version of the Wiring Regulations should we use?
This is video number 222 and to view all our videos type in LearnElectrics all one word into the KZhead search bar.
.

Пікірлер
  • The way he explains no one could ever, I’m watching hes videos and it’s so helpful My friend recommended him since I’ve learned more knowledge then college!

    @AK-ru5lt@AK-ru5lt5 ай бұрын
    • I appreciate that. Thank you. Dave.

      @learnelectrics4402@learnelectrics44024 ай бұрын
  • I’ve come across so many electricians, mostly on social media saying “An Installation should be inspected and tested to the wiring regulations it was installed to”… Thank goodness you’ve made this video and cleared this up. I’ve always told them an installation is inspected and tested to the current wiring regulations but it often falls on deaf ears.

    @alvina69@alvina697 ай бұрын
    • Correct. Inspect to the latest Regs and then give due consideration to the Regs in force at the time. thanks for watching. Dave.

      @learnelectrics4402@learnelectrics44027 ай бұрын
    • An eicr isn't unsafe if it's not to current regs are you saying it is .are you saying that plastic consumer units are not safe are you saying because it's got no Spd it's not safe so there fore it should be inspected and tested to the reg it was installed to these things are c3s surly because too many cowboy electricians fail an eicr because it's plastic and a ropey metal one is installed and it's more unsafe then the plastic one

      @chrisbuildelectrics4755@chrisbuildelectrics47557 ай бұрын
  • Full of useful tips. A breath of fresh air that had really helped me to understand. Can't thank you enough.

    @user-qi8tv2sj4m@user-qi8tv2sj4m6 ай бұрын
    • You're very welcome and thanks for watching.

      @learnelectrics4402@learnelectrics44026 ай бұрын
  • this was well said..thank you very much now i understand much better..

    @wongsang5930@wongsang59302 ай бұрын
    • Glad it helped and thank you for watching. Dave.

      @learnelectrics4402@learnelectrics44022 ай бұрын
  • Fantastic, im a DIYer but also looking to become a Domestic Installer - No interest in career change but so I can self cert and support friends family. The industry seems geared against people like me (no doubt due to cowboys and DIY daves). Im doing my 18th Ed, Isnt & Test and PP currently and looking to join a EIC evening course (although I think it would be over 2 years from what I am reading). Your series is a fantastic resource, thankyou for sharing and making available.

    @jimbossimrigs7961@jimbossimrigs79613 ай бұрын
    • I'm a Dave, but no offence taken. Build up your skills gradually, and photograph, record everything you do, however silly it might seem at the time. It will all make up your skills portfolio. Start on small jobs that don't need notifying, in parallel with your current work. Jobs that are within your skill level. When you do register with a Competent person scheme, you will have plenty of evidence of what you have done. Good luck and keep watching. Dave.

      @learnelectrics4402@learnelectrics44023 ай бұрын
  • I ve been doing EICR for 15 years and I can’t agree with you more but Very last part of your video was very very correct and beautifully said I watch all your clips. And you have class of your own Thank you very much Dave

    @alinili5569@alinili55696 ай бұрын
    • Thanks for the great comments, really appreciated. dave.

      @learnelectrics4402@learnelectrics44026 ай бұрын
  • ❤ Fabulous video ❤ Thank you very much

    @lawrencer25@lawrencer256 ай бұрын
    • Thank you too, glad you enjoyed it, Dave.

      @learnelectrics4402@learnelectrics44026 ай бұрын
  • Very good. Thank you

    @stonegrundy123@stonegrundy1237 ай бұрын
    • Thank you too, appreciated.

      @learnelectrics4402@learnelectrics44027 ай бұрын
  • Very useful.

    @user-qi8tv2sj4m@user-qi8tv2sj4m6 ай бұрын
    • Thank you. Appreciated.

      @learnelectrics4402@learnelectrics44026 ай бұрын
  • 👍 shared 👍

    @Oufg103f@Oufg103f4 ай бұрын
    • Thank you, appreciated.

      @learnelectrics4402@learnelectrics44024 ай бұрын
  • Nice video

    @aw5026@aw50267 ай бұрын
    • Thank you, appreciated comments. Dave.

      @learnelectrics4402@learnelectrics44027 ай бұрын
  • Hi mate. Can I ask if you test R1 and R2 when doing eicr or you just calculate it? Also what tests would you do when carrying out eicr? Many thanks

    @alanmarriott9216@alanmarriott92165 ай бұрын
    • The recommendation is that you always test R1+R2 and do not use Zs minus Ze. You should carry out all the tests as per part 3 of guidance note 3. Hope this helps. Dave.

      @learnelectrics4402@learnelectrics44025 ай бұрын
  • Good

    @LoftInsulation-pj9dj@LoftInsulation-pj9dj7 ай бұрын
    • Thanks for watching. Dave.

      @learnelectrics4402@learnelectrics44027 ай бұрын
  • First off great video as always, I really do like your content. But I have a question you mention @9:30 "Light switch with metallic face - plate is installed on a metal back box with no fly - lead" is a c2. However I always thought most metal back boxes (providing it has at least one fixed lug) do not need a fly - lead as the machine screw acts as a fly - lead otherwise we would still have to take a fly - lead from a socket to a metal back box. so in this case the switch would not need a separate fly - lead.But it could be noted as an observation..... If I am wrong I would like to know thanks

    @markpotter8280@markpotter82807 ай бұрын
    • If the line conductor touches the back box, the screw may transfer the voltage to the face plate. The permutations are endless, just try and work out the sequence if something goes wrong. Thanks for watching. Dave.

      @learnelectrics4402@learnelectrics44027 ай бұрын
    • @@learnelectrics4402 Thanks for the reply. I agree 100% with what you are saying an I would always earth the metal face plate I was just querying really if that is actually a c2 or would it be more of a c3 (huge difference imo). But as you rightly stated in the video it would be for the individual inspector to decide. Thanks again for all the great content

      @markpotter8280@markpotter82807 ай бұрын
    • As long as back box is earthed then faceplate is earthed via the the screw. A short would trip the mcb. Obviously if removed then it could become live , however when should a switch be removed from the back Box live . C3 for me sorry.

      @2194jamie@2194jamie6 ай бұрын
  • 👍

    @brianhewitt8618@brianhewitt86187 ай бұрын
    • Thank you Brian. Dave.

      @learnelectrics4402@learnelectrics44027 ай бұрын
  • Learn Electrics is by far the best for learning electrics no matter what stage your at in your career...

    @miketownson9197@miketownson9197Ай бұрын
    • Thanks for the great comments. Appreciated.

      @learnelectrics4402@learnelectrics440223 күн бұрын
  • So if it's not C1, C2, FI or C3 we just tick the box?

    @ivanbuckingham2302@ivanbuckingham23027 ай бұрын
    • Yes, as its a satisfactory report, but any limitations must be recorded and signed off correctly and any notes on observations regarding anything outside the scope of bs7671 ie fire dection and hazardous environment, also any possible departures which is usually wiring or equipment being used that is not formally or currently recognised by bs7671 but still appropriate for use due to manufacturers and European compliance, all this must be signed in agreement with the customer when finished.

      @brianhewitt8618@brianhewitt86187 ай бұрын
    • Brian has this covered. Thanks for watching and thank you Brian.

      @learnelectrics4402@learnelectrics44027 ай бұрын
    • Thanks Brian, I appreciate the support. Dave.

      @learnelectrics4402@learnelectrics44027 ай бұрын
KZhead